Path to model variable:
Disciplines > ECAD > EPLAN Electric P8 > Structure identifier management
With the Parameter name for the sequence of installation site model variable the name of a parameter is specified that stores the list of installation sites in a specific sequence.
To be able to specify a specific sequence of installation sites in the schematic, a parameter by the same name must be inserted in the component of the WiringDiagram super class.
The output value is a list that consists either only of designations or pairs that are composed of a designation and a description.
=List{'Ground', 'Floor 1', 'Floor 2', 'Top'}
Result:
Row | Complete structure identifier | Structure description | Original description | Usage | Status |
---|---|---|---|---|---|
1 | Ground | ? | |||
2 | Floor 1 | ? | |||
3 | Floor 2 | ? | |||
4 | Top | ? | |||
5 | <Empty identifier> | <Empty identifier> | ? |
The description can be specified in every available language. The syntax is as follows: <Language abbreviation>@<Description>;. After the last description a semicolon must be added!
=List{Pair{'Ground', 'de_DE@Erdgeschoss;en_US@Ground Floor;'},
Pair{'Floor 1', 'de_DE@Erstes Geschoss;en_US@First Floor;'},
Pair{'Floor 2', 'de_DE@Zweites Geschoss;en_US@Second Floor;'},
Pair{'Top', 'de_DE@Obergeschoss;en_US@Top Floor;'},}
Result (set dialog language: de_DE):
Row | Complete structure identifier | Structure description | Original description | Usage | Status |
---|---|---|---|---|---|
1 | Ground | Erdgeschoss | ? | ||
2 | Floor 1 | Erstes Geschoss | ? | ||
3 | Floor 2 | Zweites Geschoss | ? | ||
4 | Top | Obergeschoss | ? | ||
5 | <Empty identifier> | <Empty identifier> | ? |
Result (set dialog language: en_US):
Row | Complete structure identifier | Structure description | Original description | Usage | Status |
---|---|---|---|---|---|
1 | Ground | Ground Floor | ? | ||
2 | Floor 1 | First Floor | ? | ||
3 | Floor 2 | Second Floor | ? | ||
4 | Top | Top Floor | ? | ||
5 | <Empty identifier> | <Empty identifier> | ? |