Check installation
General requirements
- You have selected a project of the type *.epdz or *.xls / *.xlsx and opened an instance of the project.
- All routing connections in the project have the status "Installed".
- You have selected the desired layout space, enclosure in the layout space or mounting site in the enclosure, if the project is based on a file of the type *.epdz.
- You have activated the check mode in the settings (menu items Settings > Check mode > Use) so that all the installed routing connections have the status "To be checked"
.
Procedure
- Open the detail view of the first routing connection in the connection list.
- After the wire has been checked in the enclosure, change the status of the connection symbol at the far right in the detail view as follows:
- If the wire is installed correctly, click or tap the connection symbol once.
- The status changes from "To be checked"
to "Checked"
. In this case the connection points at the source and target also receive the status "Checked".
- If the wire is installed incorrectly, click or tap the connection symbol for a second time.
- The status then changes from "Checked"
to "Correction required"
. In this case the connection points at the source and target also receive the status "Correction required".
- Repeat the check and status assignment for all other routing connections of the connection list.
The buttons at the source and target connection point show the status "Installed" , the button for the complete routing connection has the status "To be checked"
.
Note
In order to make it possible n the enclosure to assign the "Checked" status to an incorrectly marked routing connection in the connection list after another check of the respective wire the check mode must first be deactivated and the "Installed" status must be assigned to the routing connection. Only after another activation of the check mode it is possible to assign the "Checked" status at the routing connection.