P501004: The function definition <x> entered at the part is obsolete

Cause

In the parts database to be checked a part was found where a function definition was entered which is obsolete and therefore no longer permissible.

Solution

  1. In the message management dialog mark the line with the message and select the Properties popup menu item.

    The Parts management dialog is opened, the respective part is already marked in it.
  2. Bring the Function templates tab to the front.
  3. In the Device selection (function templates) table click the entry in the Function definition column that contains the obsolete no longer permissible function definition and click [...].
  4. Select an up-to-date function definition from the Function definitions dialog that is opened.
  5. Close the parts management, save the modified data, and carry out a parts synchronization.
  6. Then start a new check run.