    plcservice
    In This Topic
    Exports/imports PLC data using the specified converter.
    

    Parameter Description
    TYPE
    
    Type of task to be performed by the action:
    • "BUSDATAEXPORT": Bus data export.
    • "BUSDATAIMPORT": Bus data import.
    • "GENERATEPLCSCHEMATIC": Schematics generation.
    • "EXPORTADDRESSOVERVIEW": Address overview export.
    
    PROJECTNAME
    
    Project name with full path.
    
    LANGUAGE
    
    Language identifier 
    This parameter is only effective with the following values of the TYPE parameter: "BUSDATAEXPORT", "BUSDATAIMPORT"
    
    CONVERTERID
    
    Identification for busdata exporter. Values are:
    • "PlcDcExchangerBeckhoffTC3AML" = Beckhoff TwinCAT 3 (AR APC 1.1.0)
    • "PlcDcExchangerBoschAML" = Bosch Nexeed Automation (AR APC 1.0.0)
    • "PlcDcExchangerLogiCals3AML" = logi.cals logi.CAD 3 (AR APC 1.1.0)
    • "PlcDcExchangerMitsubishiAML" = Mitsubishi iQ Works (AR APC 1.0.0)
    • "PlcDcExchangerMitsubishi110AML" = Mitsubishi iQ Works (AR APC 1.1.0)
    • "PlcDcExchangerPhoenixContactAML" = Phoenix Contact PLCnext Engineer 2019 (AR APC 1.0.0)
    • "PlcDcExchangerRockwellArchitectAML" = Rockwell Automation Studio 5000 (AR APC 1.0.0)
    • "PlcDcExchangerSiemensTIA15AML" = Siemens SIMATIC STEP 7 TIA-Portal 15 (AR APC 1.0.0)
    • "PlcDcExchangerSiemensTIA151AML" = Siemens SIMATIC STEP 7 TIA Portal 15.1 (AR APC 1.0.0)
    • "PlcDcExchangerSiemensTIA16AML" = Siemens SIMATIC STEP 7 TIA Portal 16 (AR APC 1.1.0)
    • "PlcDcExchangerSiemensTIA17AML" = Siemens SIMATIC STEP 7 TIA Portal 17 (AR APC 1.2.0)
    • "PlcDcExchangerSiemensTIA18AML" = Siemens SIMATIC STEP 7 TIA Portal 18 (AR APC 1.3.0)
    • "PlcDcExchangerSiemensTIA19AML" = Siemens SIMATIC STEP 7 TIA Portal 19 (AR APC 1.4.0)
    • "PlcDcExchangerSiemensTSTAML" = Siemens TIA Selection Tool (AR APC 1.1.0)
    • "PlcDcAMLExchangerGeneral" = Eplan Electric P8 AML-format
    • "PlcDcXMLExchangerABB" = ABB Automation Builder
    • "PlcDcXMLExchangerBandR" = B and R Automation Studio
    • "PlcDcXMLExchangerRexroth" = Bosch Rexroth Indra Works
    • "PlcDcXMLExchangerSchneider" = Schneider Unity Pro XL
    • "PlcDcXMLExchangerSiemens" = Siemens SIMATIC STEP 7 5.6
    • "PlcDcXMLExchangerUniversal" = Eplan Electric P8 PLC standard exchange format
    This parameter is only effective with the following values of the TYPE parameter: "BUSDATAEXPORT", "BUSDATAIMPORT"
    
    CONFIGURATIONPROJECT
    
    The name of the PLC configuration data set to export. 
    This parameter is only effective with the following values of the TYPE parameter: "BUSDATAEXPORT", "EXPORTADDRESSOVERVIEW"
    
    DESTINATIONFILE
    
    Destination file for data export.
    This parameter is only effective with the following values of the TYPE parameter: "BUSDATAEXPORT", "EXPORTADDRESSOVERVIEW"
    
    SOURCEFILE
    
    Source file for data import.
    This parameter is only effective with the following values of the TYPE parameter: "BUSDATAIMPORT"
    
    OVERWRITE
    
    If the output file already exists, this parameter specifies     whether it should be overwritten.
    Possible values: 0 = No (default), 1 = Yes.
    This parameter is only effective with the following values of the TYPE parameter: "BUSDATAEXPORT"
    
    FORMAT
    
    Format of export file(optional).
    This parameter is only effective with the following values of the TYPE parameter: "BUSDATAEXPORT".
    Some of the Converters, which have multiple formats are listed here along with the possible format values
    • "PlcDcExchangerRockwellArchitectAML" = "AutomationML AR APC V1.0.0"
    • "PlcDcExchangerRockwellArchitectAML" = "AutomationML AR APC V1.1.0"
    • "PlcDcExchangerRockwellArchitectAML" = "AutomationML AR APC V1.2.0"
    • "PlcDcXMLExchangerBandR" = "SPS-Standardaustauschformat V1.0"
    • "PlcDcXMLExchangerBandR" = "SPS-Standardaustauschformat V2.0"
    • "PlcDcXMLExchangerRexroth" = "SPS-Standardaustauschformat V1.0"
    • "PlcDcXMLExchangerRexroth" = "SPS-Standardaustauschformat V2.0"
    • "PlcDcAMLExchangerGeneral" = "AutomationML AR APC V1.0.0"
    • "PlcDcAMLExchangerGeneral" = "AutomationML AR APC V1.1.0"
    • "PlcDcAMLExchangerGeneral" = "AutomationML AR APC V1.2.0"
    • "PlcDcAMLExchangerGeneral" = "AutomationML AR APC V1.3.0"
    • "PlcDcAMLExchangerGeneral" = "AutomationML AR APC V1.4.0"
    • "PlcDcAMLExchangerGeneral" = "PLC standard exchange format V1.0"
    • "PlcDcAMLExchangerGeneral" = "PLC standard exchange format V2.0"
    • "PlcDcXMLExchangerSchneider" = "Schneider XEF"
    • "PlcDcXMLExchangerSchneider" = "Schneider XHW"
    • "PlcDcXMLExchangerSchneider" = "Schneider XSY"
    • "PlcDcXMLExchangerSchneider" = "Schneider ZEF"
    
    EXPORTPORTSPECIFICINTERCONNECTION
    
    Export port-specific interconnection(optional).
    Possible values: 0 = No, 1 = Yes. If the parameter is not used, the default value is the same as what is currently set in the GUI.
    This parameter is only effective with the following values of the TYPE parameter: "BUSDATAEXPORT"
    
    EXPORTACCESSORIES
    
    Export accessories(optional).
    Possible values: 0 = No, 1 = Yes. If the parameter is not used, the default value is the same as what is currently set in the GUI.
    This parameter is only effective with the following values of the TYPE parameter: "BUSDATAEXPORT"
    
    EXPORTDRIVES
    
    Export drives(optional).
    Possible values: 0 = No, 1 = Yes. If the parameter is not used, the default value is the same as what is currently set in the GUI.
    This parameter is only effective with the following values of the TYPE parameter: "BUSDATAEXPORT"
    
    EXPORTDEVICESPECIFICCONFIGURATIONVALUES
    
    Export device-specific configuration values(optional).
    Possible values: 0 = No, 1 = Yes. If the parameter is not used, the default value is the same as what is currently set in the GUI.
    This parameter is only effective with the following values of the TYPE parameter: "BUSDATAEXPORT"
    
    IMPORTMATCH
    
    Matching options for PLC data import. 
    The import process tries to match imported objects with those existing in the project.
    Based on the option selected, the matching may be performed by internal object ids or by objects' identifying names.
    If an imported object is matched with an existing function, properties of the existing function will be updated whereas for unmatched imported objects, new functions will be created in the project.
    The options are:
    • 0 = Match by internal object ids.
    • 1 = Match by identifying names. Note: in this case, a comparison dialog may be displayed for the user to individually selecting some function to update.
    • 2 = Don't match. Create new functions for all imported objects.
    This parameter is only effective with the following values of the TYPE parameter: "BUSDATAIMPORT"
    
    CONFIGFILE
    
    A path to a "GenerateSchematic" configuration file for schematics generation.
    This parameter is only effective with the following values of the TYPE parameter: "GENERATEPLCSCHEMATIC"
    
    SINGLELINEPAGES
    
    If set, single-line pages will be generated.
    Possible values: 0 = No (default), 1 = Yes.
    This parameter is only effective with the following values of the TYPE parameter: "GENERATEPLCSCHEMATIC"
    
    MULTILINEPAGES
    
    If set, multi-line pages will be generated.
    Possible values: 0 = No (default), 1 = Yes.
    This parameter is only effective with the following values of the TYPE parameter: "GENERATEPLCSCHEMATIC"
    
    OVERVIEWS
    
    If set, overview pages will be generated.
    Possible values: 0 = No (default), 1 = Yes.
    This parameter is only effective with the following values of the TYPE parameter: "GENERATEPLCSCHEMATIC"
    
    RACKOVERVIEWS
    
    If set, rack overview pages will be generated.
    Possible values: 0 = No (default), 1 = Yes.
    This parameter is only effective with the following values of the TYPE parameter: "GENERATEPLCSCHEMATIC"
    
    PLCSTATION
    
    The name of the PLC station name to export.
    This parameter is only effective with the following values of the TYPE parameter: "EXPORTADDRESSOVERVIEW"
    
    PLCCPU
    
    The name of the PLC CPU name to export.
    This parameter is only effective with the following values of the TYPE parameter: "EXPORTADDRESSOVERVIEW"
    

    Example


    Bus data export: Example 1: plcservice /TYPE:BUSDATAEXPORT /CONFIGURATIONPROJECT:Schneider-Electric /DESTINATIONFILE:"c:\tempdir\plcservice_export_1.xef" /PROJECTNAME:"C:\Users\Public\EPLAN\Electric P8\Projects\Microsoft\EPLAN_Sample_Project.elk" /LANGUAGE:de_DE /CONVERTERID:PlcDcXMLExchangerSchneider /OVERWRITE:1 Example 2: plcservice /TYPE:BUSDATAEXPORT /CONFIGURATIONPROJECT:Phoenix1 /DESTINATIONFILE:"c:\tempdir\plcservice_export_1.aml" /PROJECTNAME:"C:\Users\Public\EPLAN\Electric P8\Projects\Microsoft\EPLAN_Sample_Project.elk" /LANGUAGE:de_DE /CONVERTERID:PlcDcAMLExchangerGeneral /OVERWRITE:1 /FORMAT:"AutomationML AR APC V1.4.0" /EXPORTPORTSPECIFICINTERCONNECTION:1 /EXPORTACCESSORIES:1 /EXPORTDRIVES:1 /EXPORTDEVICESPECIFICCONFIGURATIONVALUES:1 Bus data import: plcservice /TYPE:BUSDATAIMPORT /SOURCEFILE:"c:\tempdir\plcservice_export_2.pbf" /PROJECTNAME:"C:\Users\Public\EPLAN\Electric P8\Projects\Microsoft\EPLAN_Sample_Project.elk" /LANGUAGE:de_DE /CONVERTERID:PlcDcXMLExchangerUniversal Schematics generation: plcservice /TYPE:GENERATEPLCSCHEMATIC /PROJECTNAME:"C:\Users\Public\EPLAN\Electric P8\Projects\Microsoft\EPLAN_Sample_Project.elk" /CONFIGFILE:"c:\tempdir\schematics_generation_config.xml" /SINGLELINEPAGES:1 /MULTILINEPAGES:1 Address overview export: plcservice /TYPE:EXPORTADDRESSOVERVIEW /PROJECTNAME:"C:\Users\Public\EPLAN\Electric P8\Projects\Microsoft\EPLAN_Sample_Project.elk" /CONFIGURATIONPROJECT:"CAx_AML_Drive_00" /PLCSTATION:"S71500/ET200MP station_1" /PLCCPU:"1" /DESTINATIONFILE:"c:\tempdir\address_overview_export.csv"