P001039: Saddle jumper at terminal without saddle jumper connection point

Cause

A wrongly formed saddle jumper was found in the project. You have defined a connection between terminals as a saddle jumper in the schematic or in the dialog Edit terminal strip. However, no value for the number of saddle jumpers is entered at one or both terminals.

Solution

  1. Call up the dialog Properties for the terminals respectively.
  2. Switch to the Symbol / function data tab and open the Connection point logic dialog by clicking the [Logic] button.
  3. In the Number of saddle jumpers field, enter a value for the respective function connection points that is greater than "0" (with regard to the example a 1 each at the first function connection point).


If required, start a new check run.