- File > Settings > Company > Wire fabrication > "Machine" > Tab Machine command
- File > Export > Command group Manufacturing data > Wire fabrication > "Machine". Click [...] next to the Scheme field. Select the Machine command tab.
In this tab, you enter the machine-specific commands and assign them to conductor termination processing.
Overview of the main dialog elements:
Conductor termination processing:
The values from the Conductor termination processing column are available as values to be selected from the Conductor termination processing tab.
The To cross-section column allows you to specify the cross-section up to which the instructions entered in the Machine command field are applied.
In this column, you enter the instructions in the language of the respective machine software that are to be executed for the selected conductor termination processing.
Information on machine commands can be obtained from the manufacturers of machines.