Offline Numbering of Fluid DTs (ISO 1219-2)

For fluid devices, use a standardized identification according to ISO 1219-2; this allows the offline numbering to increment the item number in the DT.

Preconditions:

  • You have opened a project.
  • The project was created by using the Fl_1219-2_bas001.zw9 basic project. This basic project has the effect that fluid device tags are structured to ISO 1219-2 with a trade-specific Media code, a Circuit number and an Item number.
  • The project contains one or more schematic pages of the type "Fluid power schematic" with fluid devices that are identified in accordance with the standard.
  1. Select several fluid devices on a schematic page, or select several schematic pages from the page navigator, or select the project.
  2. Select the following commands: Tab Devices > Command group Devices > Number.
  3. Define with which value the item number of the respective fluid DTs is to start during offline numbering as well as the increment (difference between two consecutive numbers) in the Start value and Increment columns of the dialog Numbering (offline).
  4. Click [OK].