The check runs of the message class 502 "Part master data" are available in the parts management to verify the part master data. The project-specific check runs of the outdated message class 501 "Part master data" can no longer be executed.
Project-specific check run messages of the old message class 501 "Part master data" can still be stored in projects from older versions (2025 and older). When opening such a project you can remove these messages from the project by means of a prompt. If this has not been done, these messages continue to be displayed in the message management.
For a check run message displayed in the message management from the message class 501 you can branch via the [Properties] popup menu item into the parts management and there eliminate the error at the part. For processed messages, you can select the Completed check box and filter on this property in order to hide them.
In order to obtain a solution suggestion for the respective problem for an old check run message from the message class 501, please refer to the help for the check runs of the message class 502 "Part master data" with the same last three digits (for the check run message 501002 for example in the help for the check run message 502002).
|
Message number |
Message text |
|---|---|
|
P501001 |
The macro '<x>' entered at the part does not exist. The message applies to the part property '<y>' |
|
P501002 |
The image file '<x>' entered at the part does not exist |
|
P501003 |
The document '<x>' entered at the part does not exist |
|
P501004 |
The function definition '<x>' entered at the part is obsolete |
|
P501005 |
The layer '<u>' assigned to the macro '<x>' ('<y>' / '<z>') is user-defined. The message applies to the part property '<w>' |
|
P501006 |
The components of the macro '<x>' ('<y>' / '<z>') are not grouped. The message applies to the part property '<u>' |
|
P501007 |
The height, width and / or depth is not specified at the part: Height = <x>, Width = <y>, Depth = <z> |
|
P501008 |
The connection point pattern '<x>' entered at the part does not exist |
|
P501009 |
The drilling pattern '<x>' entered at the part does not exist |
|
P501010 |
The part '<x>', variant '<y>' entered at the assembly / module does not exist |
|
P501011 |
Part property 'Type number' is empty |
|
P501012 |
Part property 'Order number' is empty |
|
P501013 |
Part property 'Designation 1' is empty |
|
P501014 |
Part property 'Generic product group' is undefined |
|
P501015 |
Part property 'Product group' is undefined |
|
P501016 |
Part property 'Product subgroup' is undefined |
|
P501017 |
No trade is selected at the part |
|
P501018 |
The dimensions 'Width' and 'Height' stored at the part do not agree with the dimensions of the macro '<x>' ('<y>' / '<z>') (tolerance <u> percent) |
|
P501019 |
The symbol library '<y>' used in the macro '<x>' was not found in the project. The message applies to the part property '<z>' |
|
P501020 |
The accessory part '<x>', variant '<y>', '<z>', entered at the part does not exist |
|
P501021 |
Part property 'ERP number' is not unique |
|
P501022 |
The connection dimensions of the function templates do not match the connection dimensions at the connection point pattern |
|
P501023 |
The function templates of the assembly / module '<x>', variant '<y>' are not up-to-date |
|
P501024 |
Part number with blank at beginning or end |
|
P501025 |
Part properties 'PLC type designation' or 'Device description: File name' are empty |
|
P501026 |
The bus port '<x>' entered in the function templates of the part was not found in single-line representation in the macro '<y>'. The message applies to the part property '<z>' |
|
P501027 |
Connection point data at the bus port are filled |
|
P501028 |
'Plug designation' property at the bus port is empty |
|
P501029 |
The part '<z>', variant '<u>', entered at the module '<x>', variant '<y>', has neither a DT nor a DT ID |
|
P501030 |
The drilling pattern '<x>' entered at the part is incomplete. The outline '<y>' does not exist |
|
P501031 |
The general function definition '<x>' entered at the part should not be used at the part |
|
P501032 |
The channel designation entered in the function templates of the part is invalid |
|
P501033 |
The identifying connection point information of the function templates does not match the connection point data at the connection point pattern |
|
P501034 |
The PLC device identification is not unique |
|
P501035 |
The user-defined property '<x>' with the value '<y>' is not defined in the 'Configure properties' dialog. |
|
P501036 |
The part property 'ERP number' is not identical at all variants of the part. |
|
P501037 |
The standard or the company standard '<u>' in the macro '<x>' ('<y>' / '<z>') does not match the standard or the company standard of the part property. The message applies to the part property '<w>' |
|
P501038 |
The value of the part property '<x>' does not lie within the value range that is defined in the Eplan Data Standard |
|
P501039 |
The reference '<x>' in the function template for the placement of the conductor is not valid |
See also