Using the corresponding sockets for chapters and plugs for lines, it is now possible to assign the lines to the correct chapters:
- Open the Text component Sensors_Actuators_Chapter in the ListOfComponents unit.
- Switch to the Parameters editor page.
- Click on the Add parameter symbol and select the Socket parameter in the finder. Alternatively, you can also use drag & drop to add the Socket parameter.
- Add the Plug parameter to the Text component Sensors_Actuators_Line by repeating steps 1 to 3.
- Double-click to open the component Feeder in the T_Mechatronic_ModularSystem library in the Stations unit.
- Click to select the Actuators_Chapter component. The corresponding parameter table now opens.
- Enter Actuators as the value for the Socket parameter.
- Repeat the previous two steps to add the Sensors value to the Sensors_Chapter at the Feeder component.
- To enter the Actuators plug parameter value to the two actuators Valve and Cylinder (both in the Actuators subunit in the Mechatronic unit) in the component Sensors_Actuators_Line, perform steps 5 to 7.
- Repeat steps 5 to 7 for the non-abstract sensors (in the Sensors subunit in the Mechatronic unit) as well and enter the Sensors plug parameter value in the component Sensors_Actuators_Line.
- Pressuresensor
- Positionsensor_inductive
- Positionsensor_optical