Thus far, only discipline components with an abstract and a concrete derivation have been assigned parameters and parameter values.
There are still no parameters or parameter values for the following discipline components, which are also installed in the Feeder station.
- WiringDiagram
- LayoutSpace
- MountingPanel
- Plane
We begin by assigning parameters to the discipline components:
- Open the WiringDiagram component in the ProPanel unit.
- Open the Parameter editor.
- Drag the Socket parameter from the Parameter unit in the editor.
- Repeat steps 1 to 3 for the LayoutSpace component and the Plug and Socket parameters.
- Repeat steps 1 to 3 for the MountingPanel and Plane components and the Id, Plug and Socketparameters.
- The next step is to assign values to the parameters.
- Open the Feeder component.
- Select the installed WiringDiagram component.
- For the Socket parameter, enter the value LayoutSpace.
- Repeat steps 8 and 9 for the following components with the parameter values from the following table:
Component | Parameters | Value |
---|---|---|
LayoutSpace | Plug | LayoutSpace |
Socket | Enclosure | |
AE1050_500 | Plug | Enclosure |
Socket | EnclosureMounted | |
MountingPanel | Plug | EnclosureMounted |
Socket | MP_Plane | |
Plane | Plug | MP_Plane |
Socket | PlaneMounted |
The hierarchy of Pro Panel components can be recognized by the values for Plug and Socket.