Release notes
EPLAN Platform
Product | Area | Functionality | Version |
---|---|---|---|
EPLAN Platform | Graphical editor |
Deactivating anti-aliasing in case of blurry representation In the graphical editor some graphical elements were displayed blurred at a scaling of 100% under certain conditions. In order to eliminate the problems during the representation you can deactivate the anti-aliasing performed by default. The new user-specific setting Deactivate anti-aliasing is available to this purpose. (The command path for the dialog Settings: 2D is: File > Settings > User > Graphical editing > 2D.) If this check box is selected, anti-aliasing is not performed. As a result the graphical elements representation in the graphical editor becomes sharper. For certain graphical elements (such as circles, oblique lines) this can, however, lead to a "pixelated" representation or to so-called "stair steps". |
|
EPLAN Platform | Connections |
Formatting of connection definition points As of Version 2023 the Settings: Connection numbering dialog extends the Display tab with the check box Use default. With this check box you specify that the connection designations of the automatically placed connection definition points are formatted in the same way as manually inserted ones. In the past the "Default value (connection)" property arrangement was always assigned to the automatically placed connection definition points in this case. Now the property arrangement is assigned to the connection definition points that you have specified as the default for the used symbol variant of the connection definition point (for example, in the dialog Save property arrangement). This way it is now possible to format manually inserted and automatically placed connection definition points uniformly with a user-defined property arrangement. |
|
EPLAN Platform | Block properties |
Extended replacement texts for project properties Using the Block property: Replacement text project property, you could previously define up to ten tables for replacement texts (via the index). You can now define up to 100 tables for replacement texts. You can use these tables to replace the values of block properties. |
|
EPLAN Platform | Labeling |
Different improvements have been made for the export in Excel format used for the output of labeling data by means of templates:
|
|
EPLAN Pro Panel | Master data for EPLAN Pro Panel |
By default subdirectories are now considered again when searching for outlines during the master data synchronization. |
|
EPLAN Platform | Rights management |
As of Version 2022 there were two rights in the rights management for editing the settings of the parts management. The right "Parts management > Settings: Parts" only applied to a specific callup possibility of the settings dialog and has now been removed. As in the past you can edit the settings using the right "Settings: User > Management+Parts". |
|
EPLAN Platform | Labeling |
During the output of labeling data for the report type "Parts list", different export results occurred for busbar connection points depending on whether the items were marked in the bill of materials navigator or on a schematic page. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
The numbering of the displayed DT after the placement of devices in the layout space has been optimized. As a result the performance while placing has improved. |
|
EPLAN Platform | Parts management |
During the export in the EDZ format the data of the "Manufacturer" record type are now considered again. |
|
EPLAN Platform | Edit in table |
If you opened the part selection in the Edit in table view and selected a part that was not yet stored in the project, the dialog flickered. This has been corrected. |
|
EPLAN Platform | Parts management |
The sorting of the list view was lost during the update. This has been corrected. |
|
EPLAN Electric P8 | PLC |
During the addressing of PLC connection points an unexpected error occurred under specific conditions. This has been corrected. |
|
EPLAN Platform | Graphical editor |
If pages were scrolled in the graphical editor when the graphical preview and the Insert center were open, scrolling took place very slowly. The performance of this action has been improved. |
|
EPLAN Platform | Edit in table |
If you had sorted the values according to a column in the Edit in table view, the [Tab] and [Enter] keys then no longer jumped to the expected cells. This has been corrected. With [Tab] the next cell on the right is now selected again and with [Enter] the next cell below. |
|
EPLAN Electric P8 | Connections |
As of Version 2023 you can specify in the project settings for connections that PE terminals with rail contact are connected automatically. If the Automatically connect PE terminals with rail contact check box was activated and PE function templates, that were not overlapped by any function, existed in the project, problems occurred during the update of the connections. This has been corrected. |
|
EPLAN Platform | Parts management |
If the selection dialog was opened at a part for the properties Manufacturer or Supplier in Version 2023, it was not possible to create a new manufacturer or supplier via the popup menu in this dialog despite the activated setting Modification allowed during selection. This has been corrected. |
|
EPLAN Platform | PDF export |
During the PDF export an unexpected error message occurred under certain conditions. This has been corrected. |
|
EPLAN Platform | Placeholder objects |
It is now possible again to assign a specific part variant to a device via a placeholder object. |
|
EPLAN Pro Panel | Model views |
If a property text was moved in a model view by using the shortcut key [Ctrl] + [B], the text at the cursor was not visible during moving. This has been corrected. |
|
EPLAN Platform | Parts management |
If externally edited parts data were imported in the parts management, it was previously not possible to create both new main objects (for example parts) and subobjects (for example function templates) simultaneously during an import. The simultaneous creation of main and subobjects is now possible in one step. To this purpose the object ID of main and subobjects must be set to "0". For example, a new function template is created by entering "99/117/0/0 (117/0:99/0)". |
|
EPLAN Pro Panel | 3D mounting layout |
With activated object snap it was not possible under certain conditions to snap onto the handle of a device that is already placed. This has been corrected. |
|
EPLAN Platform | User interface |
The scaling of the texts was not adapted to the display setting of the computer in the dialog Device selection. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
The collision check during the placement of length-variable items did not function correctly. Only after the first length-variable item had been placed and then moved or its length changed, did the collision check react correctly. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
During measuring in the layout space the snap point in the center was not snapped as a measuring point for manually inserted cut-outs. This has been corrected. |
|
EPLAN Platform | Parts management |
If the respective selection dialog is opened in the parts management for stored files (image files, macros, etc.), the current directory of the stored files is now displayed again in this dialog. |
|
EPLAN Platform | Parts management |
In the dialog Property: External documents it was possible that the data were moved into other rows or columns within the dialog during the editing of data or during the migration of parts databases from Version 2.9. This has been corrected. |
|
EPLAN Platform | Parts management |
When using an SQL parts database, marking all entries in the list view by using the shortcut key [Ctrl] + [A] took a relatively long time. The performance of this action has been improved. |
|
EPLAN API | Methods (API) |
Since Version 2023 the insertion point of the respective symbol was erroneously always also included when determining surrounding rectangles ("Bounding boxes") by means of the GetBoundingBox method from the Placement class. This led to undesired results for some graphical elements (such as arcs). This has been corrected. |
|
EPLAN Platform | External editing |
During the import of Excel templates defined filters for spreadsheet cells were not applied to the new Excel format. Leading zeros for structure identifiers and page names were also not applied. This has been corrected. |
|
EPLAN Platform | User interface |
For certain project properties, the value can be selected from a self-extending list. If you had opened the value list in the Backstage view of Information for such a project property and then pressed the [Esc] key, EPLAN was terminated unexpectedly. This has been corrected. |
|
EPLAN Platform | Edit in table |
When copying and pasting from the editing in a table to Excel, data were lost in Version 2022. This has been corrected. |
|
EPLAN Platform | PDF export |
During the PDF export of project pages with inserted GIF files, unexpected error messages occurred and the image files were not displayed in the output PDF file. GIF files are now converted into PNG files during the PDF export. We recommend that you no longer use GIF files in EPLAN. |
|
EPLAN Platform | Reports |
The revision data are now displayed correctly again in the revision overview. |
|
EPLAN Platform | User interface |
When customizing the ribbon you can insert actions into the ribbon that are controlled via a command line. If you had subsequently edited such an entry (for example, changed a parameter in the command line), it was possible that the originally entered tooltip and description were deleted. This has been corrected. |
|
EPLAN Platform | Project management |
If an SQL Server database was set for the project management, it was possible that no values were displayed for "User supplementary fields" in the project management. This has been corrected. |
|
EPLAN Platform | User-defined properties |
When using user-defined properties, for which the value is selected from a selection list, the first list entry could not be selected. This now works again. |
|
EPLAN Pro Panel | Manufacturing data PHOENIX CONTACT clipx ENGINEER |
The interface for the AutomationML export and import of manufacturing data for PHOENIX CONTACT clipx ENGINEER has been removed from the user interface for Version 2023 Update2 and is now available as an add-on. |
|
EPLAN Platform | Block properties |
During the export of PLC connection point data for external editing not all project languages were output for block properties if the multilingual property of another block property was determined via the block property format. This has been corrected. |
|
EPLAN Platform | Bill of materials navigator |
If a new filter was created for the bill of materials navigator and a property was selected as a criterion for this filter, the check box for the quick input was subsequently no longer available in the Filter dialog. This has been corrected. |
|
EPLAN API | Interfaces |
When updating add-ons, an unexpected error message occurred if the add-on contained more than one API add-in. This has been solved. |
|
EPLAN Pro Panel | Routing connections |
If a cable duct was selected during the execution of the command Entry point into routing path network, the cancelation of this action by means of [Esc] could result in EPLAN no longer reacting or being terminated unexpectedly. This has been corrected. |
|
EPLAN Platform | Multi-user operation |
During master data editing a symbol can now only be opened again if the associated symbol library has not been exclusively locked by another user. |
|
EPLAN Platform | Navigators |
When creating a filter for a navigator, values that were selected for the filter criterion Mounting site (describing) are now saved again. |
|
EPLAN Pro Panel | 3D mounting layout |
If a 3D macro was placed several times on a mounting panel and the format property Transparency was changed at one of these macros in the property dialog, this change was applied to all placed macros. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
If devices with defined mounting clearances were placed on a mounting panel and subsequently hidden when the mounting clearances view was activated, the mounting clearances were still displayed. This has been corrected. |
|
EPLAN Electric P8 | PLC |
If you edit the properties of several PLC connection points at the same time, it is now possible to change the entries in the fields Address and Symbolic address again in the PLC connection point tab of the property dialog. |
|
EPLAN Platform | Bill of materials navigator |
If user-defined properties for parts were used as filter criteria in the bill of materials navigator, these did not yield any results. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
If a mounting rail was placed on a mounting panel from right to left or from bottom to top, the alignment of the mounting rails was no longer correct. In this case the mounting rails were placed in opposite directions. If parts were placed on these mounting rails, the parts and their device tags were displayed rotated by 180°. This has been corrected. |
|
EPLAN Platform | Pages |
If pages were copied in the page navigator and inserted via the clipboard, it was possible that changed page names and page descriptions were not applied in the subsequent dialog Adapt structure. This was the case when switching to the DT tab after the change. This has been corrected. |
|
EPLAN Pro Panel | Routing connections |
During the manual net optimization of routing connections the coloring was lost under certain conditions. This has been corrected. |
|
EPLAN Platform | EPLAN Cloud |
Since Version 2023 Update1 no contents were displayed in China for the EPLAN Cloud tab of the ribbon. This has been corrected. |
|
EPLAN Platform | Translation |
During the manual translation of texts by means of the popup menu item Translate it was possible under certain conditions that the translated texts contained too many line breaks. This occurred in particular when you specified in the translation settings that texts should be translated word-for-word, and in addition the check box Line breaks: Text-based was activated. This has been corrected. |
|
EPLAN Platform | Graphical editor |
In comparison to Version 2.9 the pasting of copied elements from the clipboard into the graphical editor could take some time. Pasting from the clipboard now takes place faster. |
|
EPLAN Platform | Graphical editor |
The display of the grid has been optimized with Version 2023 Update1. At certain screen resolutions this resulted in the grid points being displayed too large. This has been corrected. |
|
EPLAN Preplanning | User interface |
Segments of external documents and/or project pages can be assigned in the Documents / Pages tab of the property dialog. If a document was selected here, the name and file path of the document were only displayed after the [Apply] button was clicked. This has been corrected. |
|
EPLAN Platform | User interface |
When screens with high resolution (for example 4K) were used, problems could occur under certain conditions during the display of icons. This has been corrected. |
|
EPLAN Platform |
If the format property Underline is activated for a text in the graphical editor, the underline is now also printed again. |
|
|
EPLAN Platform | Navigators |
The manual entry of several values separated by semicolons now functions again for the quick input of the filter in the navigators. |
|
EPLAN Platform | Parts management |
If properties with the field type "Bool (True / False)" were used in a tree configuration (for example Part is accessory), it was possible that the sequence of the nodes was exchanged compared to Version 2.9. This has been corrected. |
|
EPLAN Platform | Graphical editor |
If a PNG image file, in which a pattern was used for the letters, was stored on a project page, this image file was displayed with representation errors. This has been corrected. |
|
EPLAN Platform | Device selection |
In the list of the device selection Selected parts: Functions / templates the correct icons are now displayed again. |
|
EPLAN Platform | User interface |
In the Backstage view (File > Help > Command group System information) the sign-in name is now always displayed in upper-case letters, even if it was entered in lower-case letters. This is done to ensure harmonization with the rights management. |
|
EPLAN Platform | Parts management |
By importing externally edited parts data, an existing ERP number could be transferred to several parts even though a system message was output. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
If a device, that was placed rotated by 180°, was duplicated with the design mode activated, the duplicated device could have an incorrect rotation after the placement. This has been corrected. |
|
EPLAN Platform | External editing |
If data for external editing were exported in the Excel format, the width of the cells in the target file was not adapted to the text. This has been corrected. |
|
EPLAN Platform | User interface |
During the selection of workspaces where the main window extended over several monitors, it was possible that the main window was only displayed on one monitor. This has been corrected. |
|
EPLAN Pro Panel | User interface |
If a layout space was open, a part marked in the Insert center was not displayed in the graphical preview. This has been corrected. |
|
EPLAN Platform | Parts management |
For large data amounts the search in the parts management could take some time. This now functions faster through optimizations for the manufacturer name and the supplier name. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 105.3.390. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Platform | Graphical editor |
If several structure boxes were placed as polylines next to each other on a project page, it was possible that structure boxes were erroneously recognized as placed within other structure boxes, depending on the position of the corner points. The device tags of these boxes were then nested accordingly. This has been corrected. |
|
EPLAN API | Actions (API) |
The graphicallayertable action for the export / import and for the import of layers only worked when the layer management was also open. This has been corrected. |
|
EPLAN Platform | User interface |
Under certain conditions, shortcut keys could not be executed or reassigned. This has been corrected. |
|
EPLAN Platform | User interface |
During a restart of EPLAN it was possible that the position and/or the width of dialogs changed for a workspace. This has been corrected. |
|
EPLAN Platform | Parts management |
The performance has been improved for the Info tab of the parts management when using an SQL parts database. |
|
EPLAN Platform | Macros |
If the elements were combined into a block during the creation of macros for the 2D panel layout, used image files (for example *.JPG or *.PNG) were not embedded in the macro. This has been corrected. |
|
EPLAN Platform | Cable |
In the cable navigator the list view can now be sorted again by double-clicking one of the column headers. |
|
EPLAN Platform | Macros |
If you wanted to generate a part from a device in a macro project and had previously changed the macro name entered at the device, the new macro name was not transferred to the part. This now works again. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 105.3.390. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN API | Actions (API) |
The graphicallayertable action for the export / import and for the import of layers only worked when the layer management was also open. This has been corrected. |
|
EPLAN Platform | User interface |
Under certain conditions, shortcut keys could not be executed or reassigned. This has been corrected. |
|
EPLAN Platform | Part selection |
When the part selection was opened, a part stored in the Parts tab was not marked under specific conditions if the combination view was selected for the part selection. This has been corrected. |
|
EPLAN Platform | User interface |
The display of the grid has been optimized for high-resolution monitors. |
|
EPLAN Platform | User interface |
In the dialog Configure property arrangements, it was previously not possible to select a node in the tree view and to export or delete the property arrangements located under this node. This is now possible. |
|
EPLAN Platform | Graphical editor |
Under certain conditions, lines, connection elements and symbols were blurry in the graphical editor. The sharpness of their display in the graphical editor depends on the monitor size in connection with the set screen resolution and the scaling in the Windows settings. The change in this update achieves improvements when using a scaling of greater than 100%. |
|
EPLAN Platform | User interface |
When customizing the ribbon, different texts were sometimes displayed for the same commands in the Customize dialog. The headers of the tooltips were shown for the available commands below the Select commands drop-down list and the displayed names were shown for the assigned commands in the Main tabs field. Uniform texts are now displayed in the two fields. For each command, the displayed name is shown here. This is also displayed later below the configured button. As a result of this change, identical texts are now displayed for some commands in the Select commands drop-down list. To differentiate between these commands, please look at the tooltips, which appear when you move the mouse pointer over the corresponding entry. |
|
EPLAN API | Actions (API) |
The graphicallayertable action for the export / import and for the import of layers only worked when the layer management was also open. This has been corrected. |
|
EPLAN Platform | Parts management |
Under certain circumstances, navigation through the tree view was slowed down considerably, in particular if there was a very high number of parts and parallel entries of parts in several tree structures. This has been corrected. |
|
EPLAN Platform | User interface |
Under certain conditions, shortcut keys could not be executed or reassigned. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
When placing a busbar adapter in the layout space, a displayed DT was erroneously written to the mounting surfaces. This has been corrected. |
|
EPLAN Platform | User interface |
Calling up the EPLAN Cloud Dashboard in the EPLAN Cloud tab of the ribbon is now no longer carried out via the command group Dashboard, but via the command group EPLAN Products. In addition, the symbol for calling up the dashboard was changed from |
|
EPLAN Platform | Part selection |
If a part selection was canceled using specific settings, an incorrect message was issued. This has been corrected. |
|
EPLAN API | Actions (API) |
If the length of a busbar was changed by means of an API action, this did not have any effect on the length of the busbar in EPLAN Pro Panel. This has been corrected. |
|
EPLAN Electric P8 | PLC |
The performance when translating and deleting translation texts has been improved in the dialog Assignment list. |
|
EPLAN Pro Panel | 3D mounting layout |
During multiple placement from the 3D mounting layout navigator onto a mounting rail, the devices were not arranged correctly. This has been corrected. |
|
EPLAN Platform | User interface |
If you worked with an undocked graphical editor and synchronized master data, EPLAN was unexpectedly terminated under certain conditions. This has been corrected. |
|
EPLAN Platform | External editing |
Under certain circumstances template files in Excel format that contained images could not be transferred correctly into a new Excel file during export. Furthermore, an error message appeared when an attempt was made to output the path function texts of the entire project. Both errors have been corrected. |
|
EPLAN Platform | Parts management |
An empty selection dialog was displayed for the Pipe class property in the parts management. This dialog is no longer needed and has therefore been removed. |
|
EPLAN Platform | Labeling |
When outputting manufacturing data for labeling using an Excel template it was possible in individual cases that an applied formula in the Excel file was not applied correctly anymore as of a specific row. This has been corrected. |
|
EPLAN Platform | Parts management |
If a part with user-defined properties was imported and a user-defined property had the field type “Bool", the entry "[No value set]" was displayed for the value of this property next to the check box. This has been corrected. |
|
EPLAN Preplanning | Structure identifier management |
Renaming structure identifiers in structure identifier management took a long time if certain pre-planning objects existed in the project. This has been corrected. |
|
EPLAN Platform | Structure identifier management |
If a user-defined structure was renamed in the structure identifier management, problems occurred when updating the identifiers in the project. This has been corrected. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 105.3.390. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Pro Panel | Views |
The associated layout space could no longer be opened via the popup menu item Open 3D view of a model view. This behavior also occurred at 2D drilling views and copper unfolds and has now been corrected. |
|
EPLAN Pro Panel | Model views |
If a project that was created with an older EPLAN version was opened in Version 2023, all model views were marked as not up-to-date. This has been corrected. |
|
EPLAN Platform | External editing |
During external editing in Excel format it is optionally possible to specify whether the column designation is to be output as well. If this option was selected and no template was used during the export, the column designation was not included in the output. This has been corrected. |
|
EPLAN Platform | Cable |
In the cable navigator the list view can now be sorted again by double-clicking one of the column headers. |
|
EPLAN Pro Panel | 3D mounting layout |
The mounting clearances of a device were not displayed during the placement and were only visible after the item was placed on the mounting surface. This has been corrected. The mounting clearances are now displayed again as soon as the mounting surface is active. |
|
EPLAN Platform | Labeling |
Various improvements have been made for the export in Excel format by means of templates (for example during the output of manufacturing data for labeling or during external editing):
|
|
EPLAN Platform | Parts management |
In the parts management and in the part master data navigator of Version 2022 no values could be entered or selected for the "Record type" filter criterion in the Filter dialog. This has been corrected. Since the filter is only valid for parts, only the values "Component", "Assembly" and/or "Module" could be selected using a subsequent dialog. |
|
EPLAN Platform | Translation |
If - while translating a text - you have selected a text in the dialog Multilingual input and open the dictionary using the [Dictionary] button, this text is now automatically entered in the Find field. |
|
EPLAN Platform | Parts management |
After synchronization with the EPLAN Harness proD Library an SQL parts database of the EPLAN platform could under certain conditions not be synchronized anymore via the action PamArticlesSyncAction with a parts database of Version 2.9. This has been corrected. |
|
EPLAN Platform | Data exchange with Harness |
During data exchange between EPLAN Electric P8 and EPLAN Harness proD the property Function text (ID 20011) is now also taken into consideration. The exchange file for the export and import of wire harness data (*.hpdex) has been extended accordingly. |
|
EPLAN Pro Panel | 3D mounting layout |
In the layout space navigator you can edit the legend item via the corresponding popup menu item. If you had sorted the displayed data in the dialog Edit legend item by double-clicking a column, it was then no longer possible to move a line with the arrow buttons. This now works again. |
|
EPLAN Platform | Messages |
If a different filter was selected in the dialog Settings: Messages and checks for a check run in the Filter column using the […] button, it was only displayed after the dialog was updated with the [F5] key. This has been corrected. |
|
EPLAN API | Methods (API) |
If the GetProjectDataCompatibility method from the ProjectManager class was applied to projects of Version 2.9, an exception was output under specific circumstances. This has been corrected. |
|
EPLAN Pro Panel | Routing connections |
If the connections of several layout spaces were routed at the same time, a faulty routing of the connections could occur. This has been corrected. |
|
EPLAN Platform | Macros |
If the Active check box for the handle was activated or deactivated in the property dialog for macro boxes in the Settings tab, this could result in EPLAN being terminated unexpectedly. This has been corrected. |
|
EPLAN Platform | Translation |
If you enter translation texts manually in the Multilingual input dialog and then use the Dictionary button to open the Dictionary dialog, it is now possible again to transfer the entered translation texts immediately into the dictionary by using the Save button. |
|
EPLAN Platform | User Interface |
Extensions for the Insert Center In the improved information area of the Insert center the most important properties for all preview tiles contained in the preview are displayed by row in a configured table. Depending on the object type in the selected preview tile the table columns show different properties. With the popup menu item Configure representation you can show further properties and determine the display sequence of the properties. |
|
EPLAN Platform | User Interface |
Optimized Adjustment of the Column Width In tables (such as property tables) the popup menu item Column width automatic adjusts the width of the columns in such a way that the table is displayed within the overall available area. Previously this option could only be deactivated by the selection of the popup menu item Adjust column width. |
|
EPLAN Platform | User interface |
Renamed dialog for customizing the ribbon The Rename dialog which you use to change the names of commands, user-defined command groups, etc. while customizing or which you can use to assign an image file to commands and actions has been changed from Rename to Edit. The associated button and corresponding popup menu item are also renamed. |
|
EPLAN Platform | User interface |
"Customize" dialog has been extended with commands of the EPLAN Cloud products The commands of the EPLAN Cloud products are now also available in the Customize dialog. They can be assigned to user-defined command groups during customization of the ribbon. |
|
EPLAN Platform | User interface |
The selection of commands for quick access has been extended with "All commands" When customizing the quick access toolbar the "All commands" entry is now also available in the Quick access tab of the Customize dialog in the drop-down list Tabs. When this entry is selected, all commands of the ribbon which are available for quick access are displayed in the field below. |
|
EPLAN Platform | User interface |
Property preview for projects in the Backstage view Apart from the recently opened projects, a property preview is now also shown in the Backstage view Open. For the project marked in the list the values of some project properties such as Project description, Company name, Last editor etc. are displayed there. In the property preview the same information is displayed as in the preview window of the Windows Explorer. |
|
EPLAN Platform | User interface |
Extension of the Tooltips for properties The display of the Tooltip has been extended for the properties in the property tables. In addition to the property name, a property description is now also displayed. |
|
EPLAN Platform | User interface |
Improved insertion via drag & drop from the list views and tables To drag a function via drag & drop from the List view of a navigator into the graphical editor, it was necessary in Version 2022 to position the cursor exactly on the frame of the marked row. Otherwise the function could not be dragged. This has been improved. If a row is marked, the cursor for the drag & drop can now be positioned everywhere in the marked row. If a table such as in the part master data navigator or in the Insert center is write-protected, the entire row instead of the individual cells is marked. Since the information area of the Insert center is now designed as a table, an object (macro, symbol, etc.) can be marked there with a click on the line and dragged directly via drag & drop into the graphical editor. |
|
EPLAN Platform | User interface |
Improved usage of the keyboard in tables You start the processing mode in a table cell by double-clicking or with the [F2] button. If you then press the [Enter] key, the cursor jumps to the next cell downwards and not to the right. This behavior enables faster editing of values within a column in the list views of the navigators and in tables (for example when editing in tables). |
|
EPLAN Platform | Macros |
Consideration of Company Standards and Standards for Schematic Macros Under schematic macros we understand 2D macros which can be placed as window and/or symbol macros for the configuration of schematics, for example on schematic pages. |
|
EPLAN Platform | Database Technology |
Internal Database Format Replaces Access Databases In the course of a modified database technology the old Access databases (*.mdb) were already replaced for Version 2022 in the Parts management by an internal EPLAN format. This replacement is now been continued in the entire EPLAN Platform. Therefore a new internal database format (*.db) is available instead of the Access databases for the Project management (project management database) and for the Dictionary (foreign language database). |
|
EPLAN Platform | Data exchange |
New Excel interface For the current version the Excel interface in the EPLAN platform has been replaced. Nothing has changed for the actual export and import of data by means of this format. In comparison to older EPLAN versions, minor visual differences may occur if special technologies such as, for example, rule-based formatting or free illustration from MS Excel are used in the Excel templates used. The Excel file format *.xlsb is not supported anymore. |
|
EPLAN Platform | Projects |
Updating the Project Databases As part of miscellaneous extensions and optimizations, the project databases have been changed in Version 2023. This has the effect that new projects are essentially created with new project databases. |
|
EPLAN Platform | Parts Management |
Updating the Parts Database If you work with several EPLAN versions (for example when switching to Version 2023) and have set an "older" parts database of Version 2022 in Version 2023, you will be prompted when opening parts management to update the parts database. If you answer this prompt with [Yes], the parts database is updated. |
|
EPLAN Platform | Parts Management |
eSTOCK Collection as new Data Source You now have the possibility in the parts management to use a collection of parts from |
|
EPLAN Platform | Parts Management |
Summarized Display for External Documents The fact whether indexed part properties belong together, such as, for example, External document: File / hyperlink [1-20] (ID 22280) and External document: Designation [1-20] (ID 22279) was previously difficult to determine in the property table on the Properties tab of the parts management. A joint display of the respective representation pairs was only possible in the list via a corresponding configuration of the properties. |
|
EPLAN Platform | Parts management |
Parts pre-filtering has been extended with product group and trade properties The parts pre-filtering can be used to pre-filter the parts of the parts management, of the part master data navigator, of the part and device selection and the devices of the Insert center on the basis of specific properties. The properties Generic product group, Product group and the properties for the trades (for example the Trade 'Electrical engineering') are now available as further filter criteria in the criteria selection of the associated settings dialog Settings: Parts pre-filtering. This way, for example, it is possible to only display devices from the generic product group "Mechanics" in the Insert center for the engineer of the mechanical elements. (The command path for the settings dialog is: Options > Settings > User > Management > Parts pre-filtering.) |
|
EPLAN Platform | Parts management |
Same technology as during the search in the Insert Center The technologies during the search in the parts management and in the Insert center have been merged. When entering search terms in the Find field of the parts management, you can now use the same operators and placeholder characters as during the search in the Insert center. During this search only the most important part properties are now considered by default, such as part number, type number, manufacturer, etc. If you enter a "p" before the search term (for example p:motor), the search is again carried out for all properties. In this case, however, the search takes longer. |
|
EPLAN Platform | Parts management |
Improved performance when opening parts management and Insert center If, for example, the last graphical editor or the parts management has been closed, the parts databases and the macro collection are not directly closed now but remain open for one more minute. If one of these databases is accessed again during this time, it does not have to be opened again. As a result, reopening of the parts management and the Insert center takes place much faster. |
|
EPLAN Platform | Parts management |
Improved import of externally edited parts data with user-defined properties In the past the XML import of externally edited parts data with user-defined properties only functioned when the user-defined properties were already previously assigned to a part. It was not possible to use the import to assign user-defined properties of another part (for example by changing the part number in external editing). Now during an XML import of externally edited parts data the user-defined properties are automatically assigned to the parts to which they are assigned in the import file. Through this change it is now possible to transfer old, free properties in the external editing into user-defined properties and then import them again. |
|
EPLAN Platform | Page navigator |
Highlighting of changed pages when numbering pages When numbering pages in the dialog Number pages: Preview of result in the Target table, the table cells that would change in contrast to the original when numbering are now highlighted with a yellow background. This affects both the page names as well as the structure identifiers. |
|
EPLAN Platform | Graphical editor |
Shortcut keys with [Shift] for ungrouping possible If you previously wanted to assign your own shortcut key for the command "Ungroup", it was not possible that this shortcut key included the key [Shift]. This key is used in the EPLAN Platform to deactivate the grouping briefly. In the dialog Customize shortcut keys you can now also use shortcut keys such as, for example [Shift] + [G], to ungroup. Depending on the tab opened in the ribbon, ungrouping also sometimes did not function via shortcut keys. This has been corrected. |
|
EPLAN Platform | External editing |
Exporting graphical connections via action using external editing Graphical connections were only output under specific conditions during the export of connections via external editing. Such connections are not exported anymore in the future using the user interface of the external editing. So that the export of connections with the representation type "Graphic" via external editing remains possible the associated action |
|
EPLAN Platform | Revision control |
Renamed setting for completion of pages In the Description of page modification dialog the setting Generate report when completing pages has been renamed into Update when completing pages. With this setting the selected report pages are updated and the reports are not generated. (A possible command path for this setting is: File > Revision control > Command group Modifications > Change tracking > Complete pages.) |
|
EPLAN Platform | Reports |
Output of information on the wire harness in a connection list When outputting a connection list for wire harnesses you can now also output information on the wire harness and its parts. To this purpose you have to adjust the forms for the connection list (*.f27) accordingly. For the placement of corresponding placeholder texts in the forms, the dialog Placeholder texts - connection list has been extended with the new elements Wire harness, Wire harness part reference and Wire harness part. |
|
EPLAN Platform | Placeholder objects |
Improved copying in placeholder objects When you edit the properties of placeholder objects in the Placeholder object tab of the property dialog you can now insert copied values from other table cells (for example the names of properties) into the Variable column again. The values inserted this way are now automatically supplemented with angle brackets (<>) and a variable with this name is generated. This behavior applies for all field types with the exception of multilingual fields. No angle brackets are added in multilingual fields. |
|
EPLAN Platform |
Master Data |
Master Data: Symbols This section provides information about the new symbols that are available to you in the master data as of the current version. |
|
EPLAN Electric P8 | Cables |
Improved behavior of shields Different improvements have been made for working with shields. Shields can now be placed with drag & drop from the navigator dialogs. During subsequent drawing of a shield it now automatically assumes the DT of the associated cable. |
|
EPLAN Electric P8 | Cables |
Improved Dialog "Edit cable" With this version the dialog Edit cable has been revised and improved. In the new dialog Edit cable you can now – in addition to assigning the cable connections to the function templates of the cable part – also view and edit the device-specific properties of a cable. To this purpose the information on the cable and cable connections are clearly displayed in two tables arranged on top of each other. Similar to the dialog Edit terminal strip specific information is now graphically visualized in separate columns, for example connection color, shields or pair index. |
|
EPLAN Electric P8 | PLC |
Moving PLC Inputs and Outputs In the past, if you wanted to assign several configured PLC connection points to other physical PLC connection points of the PLC device, meaning that you wanted to "move" the PLC connection points, you had to call up the property dialog for each individual PLC connection point and change the respective properties (such as Plug designation, Connection point designation, PLC address). As of this version the new dialog Move PLC inputs and outputs in which you can perform such moving actions from a central point is now available in the ribbon. |
|
EPLAN Electric P8 | PLC |
Extensions for the PLC Data Exchange in the AutomationML AR APC Format Version 1.3.0 PLC data exchange is possible for different PLC manufacturers in AutomationML format. Different variants exist in the AutomationML format depending on the respective usage. The " |
|
EPLAN Electric P8 | PLC |
Network properties are only still visible at bus ports Since Version 2022 the following network properties can only be edited at bus ports: |
|
EPLAN Electric P8 | PLC |
The input of the configuration project at bus ports has been moved to property table At bus ports the input of a configuration project is usually not required since this is automatically determined by the associated PLC box. For this reason the Configuration project field in the Bus data tab of the property dialog has been removed. To enter a configuration project deviating from the PLC box, the Configuration project (at PLC boxes and bus ports) property is instead available in the group box Properties of the network interface. |
|
EPLAN Electric P8 | PLC |
Renamed property "TemplateIdentifier" To prevent confusion with the property PLC station: TemplateIdentifier, the TemplateIdentifier property has been renamed to PLC device: TemplateIdentifier. These properties can be used for the exchange of device-specific configuration values during the PLC data exchange in AutomationML AR APC format. |
|
EPLAN Electric P8 | PLC |
Displaying the representation type in the dialog "Use existing PLC connection points blockwise" In the dialog Use existing PLC connection points blockwise, the representation type could previously only be displayed in the To table in the left area of the dialog. This table displays the selected, placed PLC boxes and connection points. Now the representation type can also be shown in the From table in the right area of the dialog as an additional column. This table shows the PLC boxes and connection points that you selected for re-use. |
|
EPLAN Electric P8 | PLC |
Properties no longer required for rack The following properties were only required for the PLC data exchange via the outdated "Rockwell Studio 5000 Architect 20/21" interface: |
|
EPLAN Electric P8 | Connection Numbering |
Extended Settings for the Connection Numbering The Settings: Connection numbering dialog has been extended with a filter for the potential type for this version. In addition, you now have the possibility to format the automatically placed connection definition points in accordance with the default property arrangement for manually inserted connection definition points. (A possible command path to this dialog is: File > Settings > Projects > "Project name" > Connections > Connection numbering.) |
|
EPLAN Electric P8 | Connections |
New setting for the potential extension between PE terminals with rail contact In the project settings the dialog Settings: General (for connections) has been extended with the setting Automatically connect PE terminals with rail contact (Command path: File > Settings > Projects > "Project name" > Connections > General). If this check box is activated, the potential between terminals with the function definitions "PE terminal with rail contact, x connection points" (whereby x = 1 ... 9) is automatically extended within a terminal strip. To this purpose the terminals are connected automatically with internal jumpers on the terminal strip according to their sequence. |
|
EPLAN Electric P8 | Connections |
Using the user-defined property arrangement as the default for cable connections When saving a user-defined property arrangement for connection definition points you can specify that this is to be used as the default for cable connections. During the generation and placement of the connection definition points for cable connections, the property arrangement specified in this manner was, however, not used. Instead, the property arrangement was used that was specified as the default for "normal" connections. This has been corrected. In the course of this correction the check box Default for cable connections has been added to the dialog Configure property arrangements - <Project name>. This check box is only available for connection definition points. Through this extension you can now also specify a property arrangement as the default for cable connections at a central point. |
|
EPLAN Electric P8 | Terminals |
Renamed popup menu item in the dialog "Edit terminal strip" The popup menu item Alignable accessories following in the dialog Edit terminal strip was misleading and has therefore been renamed to Enter alignable accessories at upper main terminal. With this popup menu item you specify at which main terminal the part of the alignable accessories is entered. |
|
EPLAN Pro Panel | 3D mounting layout |
Removed animation when switching a 3D viewpoint The animated rotation when switching a 3D viewpoint has been removed. The 3D view is now switched without movement. In the course of this change the user setting Rotate when changing the viewpoints which has become superfluous has been removed. |
|
EPLAN Pro Panel | Manufacturing data Steinhauer - PWA |
Changed character set coding of the export file During the export of wire fabrication data in the "Steinhauer - PWA" format the character set coding of the export file has now been changed for all languages from "ANSI" to "Unicode". The conversion as of Version V4 is supported by the machine software "PWAControl". |
|
EPLAN Pro Panel | Manufacturing data Rittal - RiPanel Processing Center |
Extended settings for the export as scheme technology For this version the interface to the manufacturing planning and control program Rittal - RiPanel Processing Center has been extended in such a way that the settings for the export are now saved as a company-specific scheme. To this purpose the dialog Export: Rittal - RiPanel Processing Center has been extended with the drop-down list Scheme and further fields (Command path File > Export > Command group Manufacturing data > Machining > Rittal - RiPanel Processing Center). In the settings to which you branch with the […] button you can now also make specifications on the file names and the subdirectories in addition to the output directory - as is usual with other export dialogs. |
|
EPLAN Pro Panel | Manufacturing Data EPLAN Smart Wiring |
Extension of the export data with connection properties As an extension for the export of wiring data for EPLAN Smart Wiring the values of the four connection properties Connection dimension source (ID 31096), Connection dimension target (ID 31097), Source: stripping length (ID 31055) and Target: stripping length (ID 31056) are now exported additionally. |
|
EPLAN Preplanning | Placeholder Objects |
New setting for the consideration of placeholder objects in the pre-planning In pre-planning placeholder objects are used in the macros to vary the data during the generation of schematics or on the generated schematic pages. The new check box Consider placeholder object in the pre-planning is now available in the property dialog of the placeholder objects in the Settings tab so that you can control the behavior of placeholder objects in pre-planning. |
|
EPLAN Preplanning | Messages |
Checking Pre-planning after Missing Detailed Planning As a rule the projects in the pre-planning are very comprehensive. If, for example, pre-planning structures are added via an import, it was previously very difficult to check whether a detailed planning was created for all segments. New check runs and an extended filter in the pre-planning navigator are now available to search for unfinished detailed planning. |
|
EPLAN Preplanning | Data transfer |
Removed data transfer from EPLAN PPE After the menu items for transferring EPLAN PPE projects were already removed for Version 2.7 this data transfer has now been irretrievably removed from the EPLAN Platform. An automatic data transfer of PPE projects does not take place anymore now and PPE projects can also not be opened in the EPLAN Platform anymore. |
|
EPLAN Education | PLC |
PLC data exchange in the "EPLAN Education for Classroom" license The export of PLC configuration files in the AutomationML format is now possible in the "EPLAN Education for Classroom" license for Version 2023. The import of PLC configurations files in the formats supported by the EPLAN Platform is now possible again. |
|
EPLAN API | Actions (API) |
New parameter of the "renumber" action to restrict the scope of numbering If you use the action |
|
EPLAN API | Actions (API) |
Filter for part properties during parts export The action |
|
EPLAN API | Methods (API) |
New method for removing image files when customizing the ribbon The new method |
|
EPLAN API | Properties (API) |
New properties for the currencies stored in the settings of the parts database By means of the new properties |
|
EPLAN API | Actions (API) |
New action for the AML export to "RiPanel Processing Center" By means of the new action |
|
EPLAN API | Actions (API) |
New parameters for the "generatemacros" action for the preparation of macros The |
|
EPLAN API | Class (API) |
If the selection of a group was determined, not all objects in the group were locked. This has been corrected. |
|
EPLAN Platform | Revision control |
When backing up completed projects it was possible that users were not deregistered from the list of active users and thus listed several times in the dialog Show user. This has been corrected. |
|
EPLAN Platform | 2D panel layout |
If a complete terminal strip was to be placed on the mounting panel of a panel layout page, it was possible that the terminals could not be placed. If the terminals were selected individually, the terminals could be placed correctly. This has been corrected. |
|
EPLAN Platform | External editing |
The import of data from external editing into the *txt format resulted in specific data of terminal strips being lost. This has been corrected. |
|
EPLAN Platform | Page navigator |
If pages were copied in the page navigator and inserted using the Clipboard, it was possible in the subsequent dialog Adapt structure that the structure identifiers were not reset to the original value via the [Reset] button in those cases where the output pages have empty structure identifiers. This has been corrected. |
|
EPLAN Fluid | Numbering |
When numbering conduit packages the conduit definition was numbered correctly, but the associated hose lines retained the original numbering if the device tags were not unique before numbering. This has been corrected. |
|
EPLAN Platform | Pages |
If the sub-identifiers of functions were changed in the Adapt structure dialog, it was possible that these sub-identifiers were generated as main identifiers and were displayed in the structure identifier management accordingly. This has been corrected. |
|
EPLAN Platform | Placeholder objects |
For free texts in placeholder objects you now also have the Angle property available in the Assignment tab during property selection. |
|
EPLAN Platform | Navigators |
If a filter was activated for an additional navigator (for example a page navigator), this also influenced the default navigator. As a result, for example, scrolling using the keys did not work anymore in the "normal" page navigator. This has been corrected. The additional navigators now have their own filters, own tree and own list configuration. |
|
EPLAN Platform | Devices |
When inserting modules, problems occurred with the display of subordinate function templates when the respective module was inserted into a structure box. This has been corrected. |
|
EPLAN Platform | User-defined properties |
If a property arrangement with a user-defined property was imported into a target project using the functionality Synchronize project data, the user-defined property was displayed as an "Invalid property" after selection of the property arrangement at the function even though the user-defined property already existed in the target project. This has been corrected. |
|
EPLAN Platform | Placeholder objects |
An inserted QR code can now be changed by means of placeholder objects by using the property Block property: Format. |
|
EPLAN Platform | Structure identifier management |
If sub-identifiers were moved upwards in the sequence in the structure identifier management so that they preceded their superior structure identifiers in the sorting, a faulty display in the page navigator occurred after updating the project. Project pages with structure identifiers that were located below the sub-identifier after moving were no longer displayed in the page navigator. This has been corrected. |
|
EPLAN Platform | Reports |
For the output of the structure identifier overview the properties Structure description Supplementary field (ID 1009), Structure description 2 (ID 1007) and Structure description 3 (ID 1008) are now additionally available as filter criteria. |
|
EPLAN API | Methods (API) |
If the coordinates of the surrounding rectangle of a symbol in the schematic were determined via EPLAN API using the method GetBoundingBox from the Placement class, then an exception occurred under specific conditions with this method for symbols without graphic. This has been corrected. In this case the coordinates of the insertion point are returned. |
|
EPLAN API | Actions (API) |
During a device selection using the XPamsDeviceSelectionAction action it was possible that the connection data was not updated depending on the selection made. This has been corrected. |
|
EPLAN Preplanning | Reports |
For parts that were entered with a number of units greater than 1 at the planning object in the pre-planning and that were also assigned to the associated main functions in the detailed planning, the incorrect quantities were output under specific conditions in part assemblies such as parts list, summarized parts list, etc. This has been corrected. |
|
EPLAN Platform | Navigators |
If multiple objects were selected in the list of a navigator (for example the connection navigator) and these objects were then sorted by double-clicking a column header, the previously specified selection was not retained. This has been corrected. |
|
EPLAN Platform | Messages |
The check message 007014 is now not output anymore at a distributed placement of distributed terminals with the same representation type. |
|
EPLAN Platform | Edit in table |
In tabular editing the properties Connection: Length with unit (ID 31003), Wire termination processing source (ID 31051), Wire termination processing target (ID 31052), Source: Stripping length (ID 31055) and Target: Stripping length (ID 31056) are now also available for the column configuration. In addition these properties can be selected in the connection and cable navigator during the configuration of the representation of tree and list and are available as filter criteria in the connection navigator. |
|
EPLAN Platform | Reports |
When generating reports of distributed terminals that were located on different pages, it was possible that the terminal diagram only displayed the correct result after the report page had been updated. This has been corrected. |
|
EPLAN Platform | Page navigator |
If page properties of a high number of pages were edited simultaneously, this could take a certain time. Saving the page properties now takes place faster. |
|
EPLAN Preplanning | Creation of the detail planning |
When creating the detail planning, the description of segments should be transferred to the generated pages by means of placeholder objects. The format element used in the value set could previously not transfer the special characters "{}" existing in the segment description. This has been corrected. |
|
EPLAN Preplanning | PCT loops |
When placing a PLC address the values for the property Symbolic address (single component) were not transferred from the superior structure segment to the PCT loop. This has been corrected. |
|
EPLAN Pro Panel | Numbering |
During the offline numbering of mechanical items an incorrectly displayed DT was assigned to the mounting surfaces of busbar supports. This has been corrected. |
|
EPLAN Pro Panel | Master data for EPLAN Pro Panel |
During the import of device data it was possible that enclosures were created correctly, but the associated accessories were assigned to the wrong device tag. This has been corrected. |
|
EPLAN API | Methods (API) |
Device data can now be imported again by means of the method ImportDevicesText from the class DeviceService. In the user interface this corresponds to the behavior of the following commands: Tab Devices > Command group Devices > Drop-down button Navigator > Import. |
|
EPLAN Platform | User interface |
If EPLAN was used with a Korean user interface, specific effects (such as a jumping cursor) could occur during text inputs in Korean when using the [Tab] key. This has been corrected. |
|
EPLAN Preplanning | Placeholder objects |
In placeholder objects which contain PCT loops or PCT loop functions, variables could previously also be selected for the properties PCT type, Implementation and Activation site and specific values for the graphical display could be selected for these variables on the Values tab (such as for example, "General - Measuring station" for the "PCT type"). However, if a value set was selected at a later point for the affected placeholder object, the graphical representation of the PCT loop or the PCT loop function in the P&I diagram did not change. This has been corrected. |
|
EPLAN Platform | Page navigator |
In the Value field of the page navigator the filter with the quick input did not function on user-defined structures if the "#" character was used in the search term. This was, for example, the case when user-defined structures with substructures were selected with a click on [...] in the subsequent dialog. This has been corrected. |
|
EPLAN Platform | Placeholder objects |
In the tree view of the placeholder object navigator only non-placed placeholder objects could be deleted by using the [Del] key in the past. Now all placeholder objects can be deleted by means of this key. |
|
EPLAN Preplanning | Reports |
If cable parts were stored at planning objects in the pre-planning, it was not possible to output the total cable length for these cable parts in the summarized parts list. This has been corrected. |
|
EPLAN Platform | Device selection |
Despite an activated setting Change symbol if function differs, the symbol was not changed during a device selection when a part with a different function definition was selected in an accessory list. This has been corrected. |
|
EPLAN Platform | Page navigator |
The values of the properties Number of pages per property (ID 11062), Page names per property (ID 11063) and Page counter per property (ID 11064) can now be changed in the dialog Page properties and via the external editing and can also be deleted accordingly. |
|
EPLAN Platform | Numbering |
While copying and pasting terminals in structure boxes, problems with the numbering of the terminals occurred under specific conditions. This has been corrected. |
|
EPLAN Platform | Master data editor |
When the properties were edited at the master data (forms, plot frames or outlines) the original directory path was not considered when saving the modifications. Instead the file was always saved in the master data directory. This has been corrected. |
|
EPLAN Platform | Labeling |
When outputting labeling data for the report type "Parts list", it was possible under specific conditions that incorrect values were output when using user-defined properties as format elements for the calculation. This has been corrected. |
|
EPLAN Platform | Project compression |
If all saved data backup directories were removed by means a project compression for a project which had already been saved once, entries subsequently still existed in the Data backup: Backup directory property. This has been corrected. |
|
EPLAN Platform | Numbering |
When using a filter scheme for the numbering of devices it was determined that the auxiliary function of a cable was numbered even though the filter scheme should have actually prevented this. The cause for this was the connection definition points of the cable that were taken into consideration as main functions during numbering. In the future, connection definition points that have a superior object (cable, conduit, etc.) are no longer handled separately when numbering, but the numbering depends on the superior object. |
|
EPLAN Platform | Devices |
If the part was selected instead of the main function when placing a device from the device navigator, it was possible that the wrong symbol was placed. This has been corrected. |
|
EPLAN Platform | Rights management |
While restructuring the list view for navigators in tables with partially editable cells the rights management was not taken into consideration. In the rights management the "Device navigator [dialog]" right from the topic area "Graphical editor / Navigator" was extended to the list views of all navigators and renamed to "Property editing in navigators" for this reason. The page navigator and the navigators in the pre-planning are not controlled via this right, since own rights are already available for these navigators. |
|
EPLAN Platform | 2D panel layout |
If a terminal strip with very many terminals was placed on the mounting panel of a panel layout page, this process could take some time. This now takes place faster. |
|
EPLAN API | Methods (API) |
When calling the PDF export via the "PdfPages" method from the "Export" class in an API offline program, the color having the color number 8 was not correctly inverted. This has been corrected. |
|
EPLAN Platform | User interface |
If more than 129 property arrangements were created for a symbol variant, the saving of these property arrangements did not function correctly. This has been corrected. |
|
EPLAN Preplanning | Reports |
If an assembly was assigned to a planning object in the pre-planning, the broken-up parts of the assembly were calculated incorrectly during the output of the parts list. This has been corrected. |
|
EPLAN Platform | Multi-user operation |
If a project was opened on a computer in multi-user operation and simultaneously closed on a different computer, this lead to the message that the data of the project has to be checked when the project was opened again. This has been corrected. |
|
EPLAN API | Actions (API) |
When generating macros from a macro project by means of the action generatemacros, page macros were written into the wrong target directory under specific conditions. This has been corrected. |
|
EPLAN API | Actions (API) |
During the automatic export of page macros from macro projects by means of the action generatemacros the parameter PAGEMACRODIR was not correctly evaluated. This has been corrected. |
|
EPLAN Platform | Connections |
If a part was selected in the property dialog of a connection in the Part tab, this part was not transferred to the associated connection definition point under specific conditions. This has been corrected. |
|
EPLAN Platform | User interface |
In the tables of the user interface (such as property tables) it is now possible again to perform multiple selections for columns of a table and adjust the width of all selected columns by using the column separator at the right edge of a column. |
|
EPLAN Pro Panel | Reports |
If a cut-out legend was output for 2D drilling views, it was possible with manually inserted cut-outs that no values were displayed for the legend items and/or for the coordinates in the cut-out legend. This has been corrected. |
|
EPLAN API | Actions (API) |
During the import of externally edited parts data by means of the action XMImportDCArticleDataAction, a dialog with the number of added parts was previously shown until the action was completed. This dialog can now be suppressed by setting the new, optional parameter SHOWIMPORTMESSAGES to the value "0". |
|
EPLAN Platform | Placeholder objects |
A multilingual text was assigned to a path function text using a placeholder object. This text was displayed not only in the selected displayed language but rather in all project languages. This has been corrected. |
|
EPLAN Platform | Numbering |
Depending on the numbering format selected for the functions of a macro, the visible device tag of a contact was displayed or not. This has been corrected. The calculation of the displayed DT has been optimized in such a way that the structure in the numbering format of the macro no longer plays any role. |
|
EPLAN Pro Panel | 3D mounting layout |
If a wire duct with outline was placed, the item labeling subsequently showed an incorrect alignment under specific conditions. This has been corrected. |
|
EPLAN Platform | Placeholder objects |
A placeholder object with a high number of value sets could not be opened. This has been corrected. Because of changed basic technologies we recommend distributing placeholder objects with a high number of value sets (> 1000) on several placeholder objects. |
|
EPLAN Electric P8 | PLC |
The property Deactivated I/O connection point (ID 20438) is now available both in the filter of the PLC navigator as a filter criterion and in the report and labeling filters for the report type "PLC diagram". |
|
EPLAN Platform | Labeling |
Problems could occur during the output of labeling data if user-defined properties were used in the schemes for the export. This has been corrected. Older schemes with user-defined properties, however, may have to be created again. |
|
EPLAN Pro Panel | 3D mounting layout |
If an assembly with activated setting Distributed placement of assembly was placed in the layout space, the action was terminated after the first placement process. This has been corrected. |
|
EPLAN Platform | User interface |
In the Customize shortcut keys dialog the shortcut keys (for example [Ins] for "Insert symbol") assigned for the commands of the insert center were not displayed and could be assigned to other commands. If this new assignment was removed, the shortcut key for the original command did not work anymore. This has been corrected. |
|
EPLAN Platform | Reports |
If a user-defined property with the field type "Bool" was entered in a form for the form property Regenerate header after change, no new data header area was generated on the output report page (for example in the table of contents) if the value of this user-defined property changed. This has been corrected. |
|
EPLAN Platform | Edit in table |
The Layout space description (ID 20235) property could be edited in tabular editing. However, the modifications were not applied. Since editing this property only makes sense at the layout space itself, the property can now no longer be edited in tabular editing. |
|
EPLAN Platform | Parts management |
The performance for switching between tree and list views has been improved for large data amounts for the parts management. |
|
EPLAN Pro Panel | Placeholder objects |
If a grouped macro with placeholder object was deleted in a layout space, the placeholder object remained in the layout space navigator. This has been corrected. |
|
EPLAN Platform | Functions |
If the Connection point logic dialog is opened for several selected functions, the character string <<…>> is displayed for properties which have different values at the functions. Such entries could not be changed immediately to a different common value. This has been corrected. |
|
EPLAN Platform | Edit in table |
In contrast to the property dialog and the property overview, the individual connection point descriptions of the property Connection point description (all) were previously separated in the tabular editing dialog by semicolons and not by paragraph marks. This has been corrected. |
|
EPLAN Pro Panel | Model views |
In the model view of a terminal box inclined by 45° the horizontal dimension help line of an automatic dimensioning did not end at the hierarchically highest item despite the setting Up to the hierarchically highest item. This has been corrected. |
|
EPLAN Pro Panel | Model views |
If model views are generated using the templates in the tab by the same name of the Model views dialog, the report pages were generated in the same sequence as the templates are sorted. When reporting a project using the command Generate project reports, the pages with the model views were output in a different sequence, however. This has been corrected. |
|
EPLAN Platform | User interface |
In the property dialogs of devices, pages, etc., the Paste properties / values popup menu item is now available again in the respective property table. In addition this popup menu item is now also available in the Property overview dialog and in the Properties tab of the parts management. By means of this functionality you can paste one or several properties, including their values, that have been copied from another object. |
|
EPLAN Platform | Navigators |
In the device navigator it was not possible to filter for the value of a user-defined property which was defined as a part reference property with multilingual selection list. This has been corrected. |
|
EPLAN Platform | Bill of materials navigator |
If a part which was assigned to a connection was deleted in the bill of materials navigator, the part in the property dialog of the associated connection definition point still existed and was displayed again in the bill of materials navigator after the connections for the entire project had been updated. This has been corrected. |
|
EPLAN API | Methods (API) |
In Version 2022 it was possible under certain conditions that no scheme could be assigned with the method AssignConfigurablePropertiesScheme from the class MDPart. This has been corrected. |
|
EPLAN Platform | User interface |
So that the default shortcut keys can also be executed and operated with an English keyboard the shortcut keys for the command Generate project reports have been changed from [Ctrl] + [Shift] + [<] to [Ctrl] + [Shift] + [,] and for the command Update reports from [Ctrl] + [<] to [Ctrl] + [,]. |
|
EPLAN Pro Panel | 3D mounting layout navigator |
If product aspects were used for structuring and the structuring had more than two hierarchy levels, sometimes not all part placements were displayed in the tree view of the 3D mounting layout navigator. This has been corrected. |
|
EPLAN API | Methods (API) |
If a part with the same variant was added multiple times via the EPLAN API by means of the method AddPart from the class MDPartsDatabase this lead to the parts database having the part with the same variant multiple times. This has been corrected. Now a part variant can only be added once via EPLAN API. |
|
EPLAN API | Properties (API) |
Up to now it was not possible to set the representation type of a function to the value "Not defined" by means of the property ManualPlacementType from the class Function. This has been corrected. |
|
EPLAN Platform | Parts management |
If a user-defined scheme was selected for the tree configuration in the settings for the parts management in Version 2022, the parts management first had to be closed and reopened so that the new tree configuration could be applied. This has been corrected. |
|
EPLAN Platform | DXF / DWG interface |
During the DXF export of a symbol which was output as a block, the further placements of the symbol in the DXF file was displayed incompletely. This has been corrected. |
|
EPLAN Platform | PDF export |
During a PDF export documents which are linked with the project and which are located in the project document directory (<Project_Name>\DOC) are also copied in the output directory. If the documents are modified, they were not updated in the same output directory during a repeated PDF export. This has been corrected. |
|
EPLAN API | Methods (API) |
When assigning a scheme for free properties at a part using the "AssignFreePropertiesScheme" method from the class "MDPart", an exception was output under specific conditions. This has been corrected. |
|
EPLAN Platform | User interface |
If a command was found using the "Tell me what you want to do?" search field in the ribbon which only had subordinate points, the subordinate points could be executed, but not the command itself. This occurred, for example, when Routing connections in the layout space and has now been resolved. |
|
EPLAN API | Methods (API) |
An error message occurred under certain conditions during the creation of a layout space by means of the "Create" method from the "InstallationSpace" class. This has been corrected. |
|
EPLAN Platform | User interface |
If a user-defined tree configuration with specific properties was set for the parts management, only the first respective part of the specific main node was displayed in the breadcrumb trail of the Insert center at devices for these properties. This has been corrected. |
|
EPLAN Platform | User interface |
When starting EPLAN by means of command line parameters, the parameter "/User" now also takes into account the setting for the user interface design. |
|
EPLAN Platform | Graphical editor |
The display property Zero as blank could not always be activated as normal for properties with numerical values in the property arrangements. This has been corrected. |
|
EPLAN Pro Panel | Routing connections |
If the routing track - while routing connections - only covered two routing paths, this could result in routing connections which went to the point of origin of the layout space and back. This has been corrected. |
|
EPLAN Pro Panel | Reports |
For drill holes which were inserted manually on an item without DT, no X- and Y coordinates were displayed in the associated cut-out legend. This has been corrected. |
|
EPLAN Platform | Navigators |
If the properties of an object were changed in the tree view of a navigator, this could lead to the cursor in the tree jumping to the last changed object and the tree view changing accordingly. This has been corrected. |
|
EPLAN Platform | Parts management |
The parts could not be filtered for function definitions in the parts management of Version 2022. If the filter criterion Function template in the part / function definition (or a similar criterion) was set in the Filter dialog, the [...] button in the Value column did not function. This has been corrected. |
|
EPLAN Platform | Subprojects |
When updating a filed-off subproject, an unexpected error message could occur and the pages in the updated original project were subsequently not write-protected anymore. This has been corrected. |
|
EPLAN Platform | User interface |
If special characters such as accent marks were entered in the ribbon in the "Tell me what you want to do?" search field, these were not correctly displayed in some languages. This has been corrected. |
|
EPLAN Platform | User interface |
If a search for parts was carried out in the Insert center which have no variant with the variant designation "1", no part was found even though such a part was available in the parts management. This has been corrected. |
|
EPLAN Platform | User interface |
The macro variants of macros were displayed multiple times in the Insert center under specific conditions. This has been corrected. |
|
EPLAN Platform | Parts management |
If a filter is activated for the parts pre-filtering, this is now displayed again in the title bar of the parts management and similar dialogs (with a percentage sign "%" in front of the name of the parts database). |
|
EPLAN Preplanning | Pipings in the pre-planning |
An unexpected error message occurred when copying and pasting piping interruptions on P&I diagram pages. This has been corrected. |
|
EPLAN Platform | Connections |
When a page is opened, the connections are updated. In projects which contain many shields this procedure could take some time. This now functions faster for the connection update thanks to optimizations. |
|
EPLAN Electric P8 | PLC |
When synchronizing functions (Tab Tools > Command group Synchronization > Drop-down button Functions > Multi-line --> all representation types) the property Symbolic address: Group (ID 20610) was not considered. This now works. |
|
EPLAN Platform | Placeholder objects |
If a page on which a placeholder object is located was not changed through the placeholder object when assigning a value set, it was possible that no other pages were changed either through the placeholder object. This has been corrected. |
|
EPLAN Platform | User interface |
When exporting a user-defined ribbon it could happen that commands were exported multiple times. This has been corrected. |
|
EPLAN Platform | Graphical editor |
When browsing project pages in the page navigator (for example by using the keyboard or by means of a double-click) it was possible that the crosshair in the graphical editor was only visible again after a movement with the mouse. This has been corrected. |
|
EPLAN Platform | Parts management |
If a scheme with user-defined properties is assigned to a part in the parts management, the values of previously assigned user-defined properties are now not overwritten anymore by the values from the scheme. |
|
EPLAN Pro Panel | Manufacturing data Steinhauer - PWA |
During the export of wire fabrication data in the "Steinhauer - PWA" format an incomplete export file was output when a Russian user interface was used. This has been corrected. |
|
EPLAN Platform | EPLAN Cloud |
If windows of EPLAN Cloud products were undocked and closed later, this could result in other EPLAN Cloud products not being opened again. This has been corrected. |
|
EPLAN Platform | Rights management |
In Version 2022 it was possible using the rights management to prevent the call-up of the EPLAN Cloud solutions. This is now not possible anymore since the corresponding entry has been removed from the rights management. The access rights to the EPLAN Cloud solutions are now only managed via the sign-in with the EPLAN ID. |
|
EPLAN Platform | Parts management |
For the action Assign function templates, shields which did not exist were entered for the conductors of cables in the Function templates tab. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout navigator |
If a bill of materials group was changed in the bill of materials navigator using the popup menu item Edit part, this could result in already placed part placements in the 3D mounting layout navigator being displayed as not placed. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
When inserting a module as a device in a layout space, the assigned 3D macro was placed with a 90° degree rotation. If the 3D macro is selected as an individual part for the insertion as a device, it is placed correctly. Now the 3D macro is also placed correctly as a module. |
|
EPLAN Platform | Parts management |
It is now possible again in the parts management to select several parts and to perform an accessory selection on the Accessories tab for all parts at the same time. |
|
EPLAN Platform | Parts management |
If an SQL server database was set for the parts management of Version 2022, the password of the SQL database was displayed in addition to the database name in the status bar of the EPLAN Platform. This has been corrected. |
|
EPLAN Platform | Parts management |
In the parts management the opening and closing of the Multilingual input dialog without modifications resulted under certain conditions in the data of the parts management being considered as modified and the change date being modified after saving. This has been corrected. |
|
EPLAN Platform | User interface |
The part property External document (ID 22210) is now available again for the property arrangements in the Display tab of a function. |
|
EPLAN Platform | Structure identifier management |
If several rows and columns of an Excel spreadsheet were pasted into the list of the structure identifier management using the popup menu item Paste copied rows, this only functioned after pasting twice. This has been corrected. |
|
EPLAN Pro Panel | Manufacturing data Rittal - Perforex / Secarex |
If empty or incomplete rework outlines were output in the manufacturing data for Rittal-Perforex BC because of non-available fins, this lead to an error message on the machine. This has been corrected. If no fins are generated, no rework outlines are now created either. |
|
EPLAN Platform | User interface |
When using user-defined property configurations not all properties were displayed correctly in some projects even though the property configurations were available. This has been corrected. |
|
EPLAN Platform | Reports |
If report pages were deleted in a project and the project was reported again, it was possible that the incorrect report type was assigned to pages during report generation. This has been corrected. |
|
EPLAN Platform | Labeling |
During the output of the labeling for the report type "Device tag list" it was possible that the visible DT was not output for all devices, depending on the selection made. This has been corrected. |
|
EPLAN Pro Panel | Model views |
During the output of a model view with automatic dimensioning, no vertical dimensioning was generated for busbars. This has been corrected. |
|
EPLAN Electric P8 | PLC |
If a counter with hexadecimal number system was used in the PLC address format, it was possible that the connection points were not numbered correctly while duplicating PLC connection points. This has been corrected. |
|
EPLAN Platform | Macros |
If the Generate protected group during insertion setting was activated for a macro box in a macro project, it was subsequently no longer possible to group the macro boxes and the associated objects via the corresponding functionality when preparing the macros for automatic generation. This was intended to prevent groups from being created in groups in macros. The functionality Group macro boxes and associated objects has now been changed so that it functions for all macro boxes. When inserting a macro, the other superfluous groups contained in the macro are removed when the protected group is generated. |
|
EPLAN Platform | Parts management |
If the data of a part was changed in the Properties tab and you clicked the [Apply] button, the displayed area of the properties moved upward. This has been corrected. |
|
EPLAN Platform |
Printing with the [Ctrl] + [P] shortcut key is now possible again. When this shortcut key is executed, the Backstage view Print is opened and the |
|
|
EPLAN Preplanning | Creation of the detail planning |
When placing a page macro from the pre-planning navigator the wrong macro name was displayed in the embedded window macro. This has been corrected. |
|
EPLAN Platform | Parts management |
During the import of an XML file created with Version 2.9 into the parts management problems occurred with texts which were not identified as to be translated. This has been corrected. |
|
EPLAN Platform | Messages |
When synchronizing distributed functions between different representation types, the configuration project for the PLC boxes was erroneously transferred to other representation types (as of Version 2.8). Since the configuration project must only be available at the main function, such a synchronization resulted in the output of check run message 004046. This has been solved. The configuration project of the PLC box is now not transferred anymore to further representation types during synchronization. |
|
EPLAN Preplanning | Reports |
If objects were marked on the report pages for the pre-planning, these could not be selected in the pre-planning navigator using the Synchronize selection command. This has been corrected. |
|
EPLAN Platform | Graphical editor |
If a hierarchy level with many pages was selected in the page navigator, not all pages were always displayed in the graphical preview. This has been corrected. |
|
EPLAN Electric P8 | PLC |
If the PLC cards with empty configuration projects were connected within a network, the export generated faulty links. This does not happen anymore now. No links are output anymore in the AML file for such PLC cards that were not exported. |
|
EPLAN Platform | Parts management |
When filtering for texts in the parts management using the input in the "Find" field, various object types such as "Drilling pattern" were not considered in Version 2022. This has been corrected. In addition this filter now also affects the data of the object types "Customer" and "Manufacturer / supplier". |
|
EPLAN Platform | EPLAN Cloud |
If the "Automatic" option was selected in the EPLAN Platform for the User interface design setting, this lead to an undesired behavior in some older Windows versions. This has been corrected. For Windows versions without light or dark mode, the dark user interface design is now also used for the "Automatic" setting in the windows of the EPLAN Cloud products. |
|
EPLAN Platform | Bill of materials navigator |
All terminals of a terminal strip were displayed in the bill of materials navigator with a set view Bill of materials grouping below a hierarchy level for a bill of materials group even though this bill of materials group was only entered at one terminal. This has been corrected. |
|
EPLAN Platform | Placeholder objects |
If parts were assigned to the main functions in the schematic via a placeholder object, it was possible that in the subsequent conflict dialog for the function overwritten values were displayed which were then not applied though. This has been corrected. |
|
EPLAN Platform | User-defined properties |
User-defined part properties which are assigned for part references were not - as is usual - sorted according their identifying name in the Parts tab of the property dialog. This resulted in an incorrect sequence. This has been corrected. |
|
EPLAN API | Interfaces |
When registering add-ons with integrated API add-ins the restriction for specific product variants was ignored in the install.xml. This has been corrected. |
|
EPLAN Platform | Macros |
When updating macros, property arrangements which are already available in the project are not overwritten. After updating the names of property arrangements that do not match the displayed arrangements anymore were displayed erroneously. This has been corrected. (If the updated property arrangement does not match a property arrangement available in the project anymore, "User-defined" is displayed for this property arrangement.) |
|
EPLAN Pro Panel | 3D mounting layout |
When inserting a mounting grid on a frame profile, a horizontal instead of a vertical grid was erroneously created under certain conditions. This has been corrected. |
|
EPLAN Platform | Pages |
If modifications were performed while copying and pasting a high number of pages in the dialog Adapt structure on the Page tab, this could result in EPLAN being terminated unexpectedly. This has been corrected. |
|
EPLAN Platform | Macros |
If a page with a macro box was opened in a macro project, the page was displayed as selected during Generate automatically in the subsequent dialog. However, no macro was generated. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
If items were placed on a copper rail with a mounting surface and mounting line, these items could subsequently not be moved anymore by using the Placement options dialog when the With reference to original position setting was activated there. This has been corrected. |
|
EPLAN Platform | DXF / DWG interface |
During the export of a device tag list as a DXF / DWG file it was possible that the connection point designations of symbols were located on the output page below the plot frame. This has been corrected. |
|
EPLAN Platform | Structure identifier management |
It is now possible again to move lines via drag & drop in the list of the dialog Structure identifier management. In the process the position is also indicated again by a thick red line beneath which the moved lines are inserted. |
|
EPLAN Platform | Navigators |
Automatic scrolling from the visible area is now active again in the tree views of the navigators. This way pages in the page navigator can, for example be moved again with drag & drop in the areas which were not visible initially. |
|
EPLAN Platform | Parts management |
The data of a copied part could previously only be transferred in the tree view to a selected part / variants. This has been corrected. The popup menu item Paste data is now also active in the list view. |
|
EPLAN Platform | User interface |
In Version 2022 it was erroneously possible that when the shortcut keys were customized, keys which were already used internally for functionalities were assigned to other commands. For example, for the [F1] key this resulted in the command being executed at the same time as the help system was called up when [F1] was pressed. This has been corrected. If an internally used key or shortcut key is now specified in the Customize shortcut keys dialog, the text is shown as "Internally used" and an assignment is not possible. |
|
EPLAN Pro Panel | 3D mounting layout |
If an item was placed on the mounting line of a copper rail by using the orthogonal function, a different mounting surface was used instead of the originally selected mounting line when the cursor was moved onto another mounting point. This has been corrected. |
|
EPLAN Platform | User-defined properties |
After the import of older projects from Version 2.7 into newer Versions (2.9 and higher), the values of user-defined properties which were defined as part reference properties were displayed erroneously in the Part tab of the property dialog. This has been corrected. |
|
EPLAN Platform | PDF export |
If pages with device data were also output during the PDF export, only one variant was listed for a part with two variants. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
If multiple variants of a part where each variant contains a separate drilling pattern were placed as devices in the layout space using the Insert center, a drilling pattern was only displayed for the first part variant. No other value was entered for the Used drilling pattern property at the other part variants in the property dialog of the part placement. This has been corrected. |
|
EPLAN Platform | Parts management |
If instead of the shortcut key [Ctrl] + [Enter] the shortcut key [Alt] + [Enter] was entered in the Function templates tab in the Connection point designations column for inserting a line break, EPLAN was terminated unexpectedly. This has been corrected. |
|
EPLAN Platform | Graphical editor |
If several Clipboards were used while copying and pasting different objects, the plot frame was erroneously displayed in the preview of the Paste dialog in some cases. This has been corrected. |
|
EPLAN Pro Panel | Placeholder objects |
If a device to which a macro with placeholder object was assigned was placed in a layout space, the values of the selected value set were changed (erroneously) through the subsequent numbering. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
If a terminal strip was placed from the 3D mounting layout navigator into a layout space via the popup menu item Place, a filter activated for this navigator was not taken into consideration. This has been corrected. |
|
EPLAN Electric P8 | PLC |
In channels with several I/O connection points only one may be active at any given time. The further I/O connection points can be identified as deactivated by means of the Deactivated I/O connection point property. Deactivated PLC connection points are treated like power supplies and not considered by check run 004020 and during the export of PLC configuration files. If PLC connection points with the function definition "PLC connection point, variable" were identified as deactivated, they were in the past still considered for these actions. This has been corrected. |
|
EPLAN Platform | Placeholder objects |
When selecting variables in placeholder objects, problems occurred with displaying the selected variables in the Assignment tab. The variables were only displayed after the dialog was opened again. This has been corrected. |
|
EPLAN Platform | Navigators |
In the dialog Settings: Project groups (definition) the entry "Parts" could be selected by mistake as the type for additional navigators. This has been corrected. |
|
EPLAN API | Methods (API) |
If 3D graphic data was exported in the STEP Format from the Export3D class by means of the method InstallationSpacesToStep, specific settings from the export scheme were not considered. This has been corrected. |
|
EPLAN API | PLC |
Since some manufacturers of PLC configuration programs have already changed over to the AutomationML standard for Version 2022 in the EPLAN Platform, the converters "PlcDcXMLExchangerBeckhoff" und "XMLRockwellExchanger" have been removed. |
|
EPLAN Platform | Navigators |
A horizontal scroll bar is now shown again in the tree view of the navigators and the project management if the displayed objects and texts do not fit in the dialog width. |
|
EPLAN Platform | Macros |
If you inserted several macros consecutively in Version 2022, the Variant drop-down list was not updated in the Open dialog. The list always shows the variants of the first macro for all further macros. This has been corrected. |
|
EPLAN Platform | Project compression |
If unused symbol libraries were removed via project compression for a new project which was created by means of the basic project NFPA_Inch_bas001.zw9, symbol libraries stored in the project, such as the symbol library SPECIAL_en_US were removed as well. This has been corrected. |
|
EPLAN Platform | PDF export |
During a PDF export of a project with the Simplified jump function setting, overlapping jump areas result on pages of the type "Panel layout" for specific part placements (such as PLC cards) in the generated PDF file. This partially resulted in jumps to the incorrect PLC card in the schematic. This has been corrected. |
|
EPLAN Platform | Parts management |
The selection was lost in the tree or in the list of the parts management when deleting a search term or when deactivating a filter. This has been corrected. |
|
EPLAN Platform | Page navigator |
The page properties Checked by (ID 11082) and Checked date (11083) are now available as filter criteria in the filter of the page navigator. |
|
EPLAN Platform | Parts management |
When working in the parts management with an SQL parts database, saving after a change in the function templates took some time. This has been corrected. |
|
EPLAN Electric P8 | PLC |
While addressing multiple PLC cards for which no start value was entered in the Start address of PLC card property, it was possible that the carry over for the first counter was calculated incorrectly. This has been corrected. |
|
EPLAN Pro Panel | Model views |
In a model view the property texts for terminals were not displayed with simplified representation and with the application of the item labeling from the layout space, if in the user-specific 3D settings for graphical editing the Terminal strips (block definition) setting was deactivated in the Apply simplified representation to group box. This has been corrected. |
|
EPLAN Platform | Parts management |
The search index was not updated when carrying over parts data via the action XPamArticlesSyncAction from a new parts database into an older parts database for Version 2.9 (or older). Therefore you could not search for updated parts in the old parts database. This has been corrected. |
|
EPLAN API | Actions (API) |
Using the action XEsUserPropertiesExportAction no user-defined properties could be exported when the project was opened write-protected or if it was opened exclusively by another user for editing. This has been corrected. |
|
EPLAN Pro Panel | Routing connections |
If during the automatic optimization of nets the net contained functions with a subordinate DT (for example, when using module parts), it was possible that connections were missing in the associated net definition point after the optimization. This has been corrected. |
|
EPLAN Platform | User-defined properties |
The displayed name and the description of a user-defined part property were previously only translated or output during the creation of a missing-word list if the Translate property value check box was activated in the configuration dialog. Since this setting is only available for part properties with the field type "Multilingual text", the displayed names and the descriptions of part properties could not be translated with other field types. This has been corrected. The displayed names and descriptions of the user-defined part properties are not translated in accordance with the settings for the scope (dialog Settings: Parts management). |
|
EPLAN Platform | Reports |
If the Suppress in bill of materials (if filtered) property was used as a sorting criterion during the output of a summarized parts list, incorrect sorting and an incomplete summary of the parts was the result. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
When placing a terminal strip from the 3D mounting layout navigator with an activated collision check, a collision check was only carried out when the first terminal was placed. The further terminals were placed despite collision. This has been corrected. |
|
EPLAN Platform | Device selection |
During device selection the selection of the accessories from an accessory list takes place by means of the Select accessories dialog. In this dialog the Technical characteristics (ID 22017) property is also available for the column configuration. |
|
EPLAN Platform | PDF export |
During the PDF export of project pages via a command line call with the output in "Black and white", white lines were displayed on a white background for autoconnect lines with the EPLAN color number 7 in the generated PDF file. This has been corrected. |
|
EPLAN Platform | Parts management |
If the Modification allowed during selection setting was activated for the parts management, modifications to the individual parts of an assembly could be made during a part selection for this assembly. This has been corrected. |
|
EPLAN Platform | Reports |
If you entered properties from the "Revision" category in a form for the Combine in a line by form property (such as, for example,Revision name (change tracking)), the data on the respective report page (for example in the revision overview) were not combined in a line. This has been corrected. |
|
EPLAN Platform | Navigators |
In navigators (such as the device navigator) renaming by using the [F2] button did not work under certain conditions. This has been corrected. |
|
EPLAN Preplanning | Messages |
For planning objects the check run message 028014 was displayed even though no part was stored at the planning objects. This has been corrected. |
|
EPLAN Platform | Graphical editor |
If property texts of symbols were moved in the graphical editor, some symbols could subsequently not be moved via drag & drop. This has been corrected. |
|
EPLAN Platform | Parts management |
If more than 16 characters were used in the parts management for the short description of manufacturers, not all parts were displayed in the tree view for the node of the same name. This has been corrected. Now 30 characters are possible again. |
|
EPLAN Platform | Graphical editor |
If a zooming in or zooming out several times consecutively by means of the mouse wheel took place for an opened project page with many image files, this could result in EPLAN being terminated unexpectedly. This has been corrected. |
|
EPLAN Preplanning | P&I diagrams |
While duplicating objects on P&I diagram pages the assignment to the structure segments was lost for structure boxes in the pre-planning. As a result the structure boxes and the objects located within the boxes were numbered incorrectly. This has been corrected. |
|
EPLAN Electric P8 | PLC |
In the dialogs Use existing PLC connection points blockwise, Use existing PLC addresses blockwise and Move PLC inputs and outputs the performance when moving table cells has been improved. |
|
EPLAN Pro Panel | Master data for EPLAN Pro Panel |
The import of routing connections has been improved. For terminals an assignment of source and target is now also possible again via the terminal and connection point designations. |
|
EPLAN Platform | User interface |
If several opened project pages in the graphical editor were assigned in several tab groups, the tab was positioned on the ribbon after closing a project page as if no project page was open. This has been corrected. |
|
EPLAN Platform | Reports |
While generating a connection list an incorrect sorting was output when the Connection: Cross-section / diameter with unit property was used as the sorting criterion. This has been corrected. |
|
EPLAN Platform | Parts management |
If a tree configuration with specific properties was set for the parts management when working with a SQL parts database, this could result in parts being displayed double in the tree view. This has been corrected. |
|
EPLAN Platform | Translation |
If you specified in the translation settings that texts should be translated by word, and in addition the check box Line breaks: Text-based was activated, it was possible that no line breaks existed in the translated text. This behavior occurred when the entire sentence was found in the dictionary. In this case the entry is not translated word-by-word, but rather used for the entire sentence. Line breaks from the source text are lost. This has been corrected. If the entire sentence is found in the dictionary during the word-by-word translation, the line breaks are now set at a similar position to that in the source text. |
|
EPLAN Platform | Page navigator |
In the dialog Number pages: Preview of result a conflict for the page names was no longer displayed with a selection when numbering pages. This has been corrected. |
|
EPLAN Platform | Graphical editor |
While inserting dash-dot or point lines in the graphical editor the points were not displayed anymore if the line thickness was set to the value "0.00 mm" in the properties of the line. This has been corrected. |
|
EPLAN Electric P8 | Terminals / plugs |
In the dialogs Edit terminal strip and Edit plug the marker of the currently selected table cells was lost during specific actions (part selection or selection of a level). This has been corrected. |
|
EPLAN Platform | Parts management |
If a part was selected in the list view of the parts management and the Edit externally dialog was opened via the popup menu item Export data, the selection was ignored and the check box Apply to entire parts management was activated in the dialog. This has been corrected. |
|
EPLAN API | Actions (API) |
The execution of the changeLayer action for changing layer properties took significantly longer during the customizing of many layers than the manual customizing via the layer management in the user interface when several project pages were open. This has been corrected. |
|
EPLAN Platform | Graphical editor |
If elements with numerous objects or extensive graphics were selected and moved or duplicated in a 2D editor, this process could take some time. This now takes place faster. |
|
EPLAN Platform | Parts management |
If the Manufacturer property was used for the tree configuration in the parts management and if this was not the last node in the tree view, the parts below the last node were displayed double or incorrectly. This has been corrected. |
|
EPLAN Platform | User interface |
In some drop-down lists, for example for the selection of a line type or a color, the selection with the keyboard did not function. If a selected value was confirmed with the [Input] button, it was subsequently not possible anymore to change the table cell with the cursor buttons. Instead the values of the drop-down list were run through. This has been corrected. |
|
EPLAN Platform | Bill of materials |
During the export of the bill of materials list in XML format a part was listed under an incorrect DT under specific conditions. This has been corrected. |
|
EPLAN Platform | Parts management |
If a specific language was selected in the parts management in the Filter dialog for a filter criterion in the [Language] column, this setting was not saved under specific conditions and reset to the "All project languages" entry. This has been corrected. |
|
EPLAN Pro Panel | Model views |
If the properties for two model views which are located on one project page were edited together and specific 3D objects were hidden in the property dialog via the [Toggle] button, this was only implemented for one of the model views. This has been corrected. |
|
EPLAN Platform | Graphical editor |
After property texts had been moved in the graphical editor, it was possible that the icon for the set option "From layer" was not displayed anymore in the View tab of the property dialog for the display property Angle. This has been corrected. |
|
EPLAN Platform | Parts management |
If a filter for specific product subgroups was created in the parts management (for example "Plug: Switching jumper"), it was possible that a different value (for example "Terminals: Switching jumper") was displayed in the Filter dialog than in the value selection. This occurred for properties which are used in multiple product subgroups. Now the subgroups are listed behind the property name in brackets both in the Filter dialog as well as during the value selection (e.g. "Switching jumper (terminals, plugs)"). for such properties. |
|
EPLAN Platform | User interface |
In some table cells numerical values can be entered by using two arrow buttons, for example in the Parts tab of the property dialog in the Number of units / quantity column. Under certain conditions the numerical values entered this way were not correctly saved when the dialog was closed with [OK]. This now works again. |
|
EPLAN Platform | Graphical editor |
The "Arial Black" font was displayed incorrectly in the editors. This has been corrected. |
|
EPLAN Platform | Graphical editor |
If the property texts of functions (such as the engraving text) were edited when the options Direct editing were activated, the available values could be selected via a selection list but not applied. This has been corrected. |
|
EPLAN Platform | User interface |
When inserting texts copied from MS Excel into a property table of the EPLAN platform, the last line break is now not inserted anymore. |
|
EPLAN Platform | Macros |
If a macro is selected in the parts management at a part, the last used macro directory is now preset again. This behavior also applies for the selection dialog when inserting page macros in the page navigator. |
|
EPLAN Platform | Parts management |
If values were entered in the User-defined properties tab for a user-defined property and then a changeover to a different tab of the parts management carried out, the entered value was deleted. This has been corrected. |
|
EPLAN Platform | User interface |
Previously the commands Format and Copy format could not be inserted into the quick access toolbar. This has been corrected. |
|
EPLAN Pro Panel | Manufacturing data Rittal - PWA |
During the export of manufacturing data for wire fabrication in the "Steinhauer - PWA" format an error message was output when an attempt was made to export items that, from a data processing point of view, are not length-variable items (for example rails on busbar adapters). This has been corrected. |
|
EPLAN Platform | Translation |
If the translation setting Translate on input was activated, an automatic translation was also performed when manual translations were entered in the Multilingual input dialog. If the entered text did not exist in the dictionary, the translation is deleted. This has been corrected. The automatic translation is now only performed again for direct inputs in input fields or table cells. |
|
EPLAN Platform | PDF export |
If a page filter with the filter criterion "Function on page / product (main identifier)" was used during the PDF export, no pages were output during the export even though pages with this activated filter were displayed in the page navigator. This has been corrected. |
|
EPLAN Platform | Parts management |
When synchronizing a newer parts database from Version 2022 with a parts database of Version 2.9 no functioning progress bar was displayed for larger data amounts and longer duration. This has been corrected. |
|
EPLAN Platform | Parts management |
In the part property Cable assignment diagram form it is now possible again for parts of the "Cable" product group to select a form using |
|
EPLAN Platform | Parts management |
A change of the SQL parts database in the settings of the parts management resulted in a system error and no parts were displayed in the part master data navigator. This has been corrected. |
|
EPLAN Platform | Graphical editor |
If the extended clipboard of Windows 10 was used for editing property texts with an activated option Direct editing, a text could be selected but not inserted anymore. This has been corrected. |
|
EPLAN Platform | Placeholder objects |
In placeholder objects the column width of value sets could not be adjusted via the column separator using the mouse on the Values tab under specific conditions. This has been corrected. |
|
EPLAN Platform | DXF / DWG interface |
If all EPLAN colors are set to a CAD color (for example 2 = yellow) in the scheme for the DXF / DWG export, all displayed elements of this color are now displayed again in the exported DXF / DWG file. |
|
EPLAN Pro Panel | Layout space navigator |
If two or more layout spaces in the graphical editor were open in separate windows, the names of the layout spaces were not highlighted in bold anymore in the layout space navigator. This has been corrected. |
|
EPLAN Platform | User interface |
In the property dialog it was possible during longer work with EPLAN that a time lag occurred while opening the tabs Display or Format. This has been corrected. |
|
EPLAN Platform | External editing |
If the action XMExportConnectionsAction was performed for the export of connection properties for external editing as a command in the ribbon, the project specified via the ProjectName parameter was opened write-protected so that the externally edited target file could subsequently not be imported into the project. If a project is now specified in the command line of the command with /ProjectName and immediate importing after external editing is specified via /ExecutionMode:2, the project is opened editable and the externally editable target file is imported again. |
|
EPLAN Pro Panel | Views |
When 2D drilling views with threaded holes are output, the core holes in the 2D drilling views are now displayed norm-compliant. |
|
EPLAN Platform | Labeling |
It was not possible in the Settings tab of the Settings: Manufacturing data export / Labeling dialog to remove the value set for the Filter setting setting by means of the [Del] key. Even if nothing was displayed, the previously set filter was still active. This has been corrected. |
|
EPLAN Platform | Parts management |
When values with decimal places were displayed, inconsistent rounding occurred in the parts management. This has been corrected. |
|
EPLAN Platform | Rights management |
When EPLAN was started with activated rights management, the start screen was closed as soon as the sign-in dialog was opened. After confirming the password with [OK], the EPLAN icon was no longer displayed in the task bar. It was therefore not clear for the user whether the start procedure was continued. This has been corrected. |
|
EPLAN Platform | Placeholder objects |
In placeholder objects it is now possible again to exchange symbols via the selection of value sets. |
|
EPLAN Platform | Page navigator |
After a page had been deleted in the page navigator the marking was not placed at the next page in the tree, but the marking was lost. This has been corrected. |
|
EPLAN Pro Panel | Routing connections |
While routing connections from an item to a terminal strip, saddle jumpers on the terminals meant that no entry into the routing path network could be determined so that as a result a correct route was prevented. This has been corrected. |
|
EPLAN Pro Panel | STEP format |
When STEP files with activated check box Only external representation of the enclosure were exported, it was possible that not all items of the external representation for a layout space were exported under specific conditions. This has been corrected. |
|
EPLAN Platform | Graphical editor |
If a text on a project page was copied by means of the popup menu item and inserted again, the text to be inserted was only visible again after a movement with the mouse. This has been corrected. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 99.2.120. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Platform | Functions |
When using existing functions, problems could occur at complex macros, which resulted in not all device tags being assigned correctly. This has been corrected. |
|
EPLAN API | Methods (API) |
When calling up the CopyTo method from the Page class, the progress bar was always displayed even without the use of the Progress class. This has been corrected. |
|
EPLAN Platform | Graphical editor |
While inserting diagonal connections on project pages, the arrows displayed at the cursor while drawing the diagonals were always displayed in black for each set color scheme. This has been corrected. |
|
EPLAN Platform | 2D panel layout |
When placing items from the 2D panel layout navigator onto the mounting panel of a panel layout page using drag & drop, problems occurred if a multi-line page was opened in an undocked window. This has been corrected. |
|
EPLAN Platform | Parts management |
If a multilingual property was used for a user-defined tree configuration in the parts management, this could result in parts being displayed below an incorrect node and no value being displayed for this property in the list view if values of the respective property were identified as not translatable. This has been corrected. |
|
EPLAN Platform | Navigators |
If several objects were selected below a device in the device navigator, the graphical preview remained empty if a part for which no image was stored was located below the selected objects. This has been corrected. Now objects for which no preview is possible are ignored and a preview is displayed for the other objects. |
|
EPLAN Electric P8 | Edit in table |
The properties CPU: Name [2] to CPU: Name [128] could be edited in tabular editing even if the respective PLC box was marked as a CPU. This has been corrected. Furthermore the property CPU: Name [1] is now always write-protected in tabular editing and can only be edited in the property dialog of the respective PLC box. |
|
EPLAN Platform | Macros |
During the automatic generation of macros from a macro project, path variables in the Macro definition tab resulted in no macros being generated and error messages being output. This has been corrected. |
|
EPLAN Platform | Placeholder objects |
If you carried out the action Adopt variables in the property dialog of placeholder objects in the Assignment tab via the popup menu, this process could take a long time. This now runs faster. |
|
EPLAN Platform | Structure identifier navigator |
When moving structure identifiers with subordinate structures in the structure identifier navigator, the subordinate structures were not sorted correctly, depending on whether the tree or list view was selected. This has been fixed._. |
|
EPLAN Preplanning | Creation of the detail planning |
During the placement of macros via drag & drop from the pre-planning navigator, the wrong macro name was entered at the macro box of the placed macro under specific conditions. This has been corrected. |
|
EPLAN Platform | Parts management |
If a macro is selected in the parts management using the dialog Select macro, a correct preview is now displayed again in the dialog Graphical preview for the selected macro. |
|
EPLAN Platform | Graphical editor |
If an AutoCAD file was imported as a project page during the DXF / DWG import, it was possible under certain conditions that filled polylines were displayed incorrectly. This has been corrected. |
|
EPLAN Platform |
If you have selected a project in the page navigator and want to print only the filtered pages of an active page filter, it is now possible again to activate the Selection option in the Print dialog. |
|
|
EPLAN Pro Panel | Routing connections |
When the source and target of a routing connection were exchanged, the routing direction did not change, i.e. the properties Routing direction source (ID 31114) and Routing direction target (ID 31115) were not exchanged. This has been corrected. |
|
EPLAN Platform | Project options |
If a section is selected for project options in the navigator, it is displayed in the graphical preview. By double-clicking the graphical preview you can now jump to the associated project page again. |
|
EPLAN Platform |
If you selected a different printer than the default printer in the Backstage view Print and changed a setting in the printer properties (for example the page format), the print preview was not updated. This now works again. |
|
|
EPLAN Platform | Graphical editor |
If several structure boxes were placed as polylines next to each other on a project page, it was possible that structure boxes were erroneously recognized as placed within other structure boxes, depending on the position of the corner points. The device tags of these boxes were then nested accordingly. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
When the collision check was activated, it was not possible to change the length of an equipped mounting rail since it erroneously always collided with an item placed on the mounting rail. This has been corrected. |
|
EPLAN Platform | Navigators |
If a part from the device list was inserted as a device in the schematic, the sorting of the parts in the device list was lost. This has been corrected. |
|
EPLAN Platform | PDF export |
During the PDF export of report pages, specific format settings for placeholder texts for the output of symbol graphics in reports were not considered. As a result the output symbol graphics in the generated PDF were always displayed in the original size. This has been corrected. |
|
EPLAN Platform | User interface |
The color specified for a project via the project group assignment was displayed under specific conditions as a border for the graphical editor even if the pages of a project without project group assignment (i.e. without color) were opened in this editor. This has been corrected. |
|
EPLAN API | Methods (API) |
When deleting unused variables for placeholder objects by means of the DeleteUnusedVariables method from the PlaceHolder class in the EPLAN API used variables were also deleted. This has been corrected. |
|
EPLAN API | Parts management |
If an "older" parts database of Version 2022 was opened by means of the EPLAN API, this parts database was automatically updated. This has been corrected. As was the case up to Version 2.9 SP1 old parts databases are now not updated automatically anymore, but opened write-protected. The EPLAN API now provides the UpgradePartsDb method from the MDPartsManagement class and the UpdateScheme method from the MDPartsDatabase class for targeted updating of parts databases. |
|
EPLAN Platform | User interface |
When customizing the ribbon it was possible under certain conditions that the tooltip and the description were not saved for an added command. This has been corrected. |
|
EPLAN Platform | Projects |
The functionality Synchronize project caused an error during the second synchronization if the source project was renamed or deleted beforehand. This has been corrected. |
|
EPLAN Platform | External editing |
The import of connection data from external editing resulted in new connection definition points being created for unchanged data under specific conditions. This has been corrected. |
|
EPLAN Platform | User interface |
The sizes of the page navigator and the graphical preview were changed when the tabular editing was opened and closed again. This has been corrected. The window sizes and positions of the navigators and of the graphical preview are now adapted in percentage terms when switching off and on. |
|
EPLAN Platform | User interface |
If the [Esc] key for the Cancel action command was removed in the Customize shortcut keys dialog, this shortcut key could not be reassigned. This has been corrected. The [Esc] key can no longer be removed. |
|
EPLAN Platform | User interface |
If the ribbon of an undocked graphical editor was minimized, it was possible to move the tabs of this ribbon up or down with the mouse wheel. This has been corrected. |
|
EPLAN Pro Panel | Model views |
If pages were scrolled in a graphical editor, it was possible under certain conditions that the contents of a model view were no longer displayed. After the view was updated via [F5], the model view was visible again. This has been corrected. |
|
EPLAN Platform | Part selection |
In the list view of the part selection, sorting by double-clicking a column header now functions again. If this procedure takes some time, a progress bar is now displayed. |
|
EPLAN Platform | Graphical editor |
When specifying an optional coordinate base point by using the Base point shift functionality, the displayed elements disappeared on the project page in specific situations. Only when the view was zoomed or updated via [F5] were the elements visible again. This has been corrected. |
|
EPLAN Platform | Parts management |
If data (parts, accessory list, etc.) were renamed to an old parts database of Version 2.9 after synchronization, this resulted in both the renamed and the original record being available in the old parts database during a renewed synchronization. This has been corrected. During the synchronization a check is carried out whether a record was renamed and if this is the case, the record with the "old" designation is deleted in Version 2.9. |
|
EPLAN Platform | Parts management |
During the synchronization of a newer parts database from Version 2022 with a parts database of Version 2.9 the activated setting of the Alignable property for terminal parts was not transferred correctly. This has been corrected. |
|
EPLAN Platform | User interface |
Previously the commands Cut, Copy, Paste and Delete from the Home tab of the ribbon could not be inserted into the quick access toolbar. This has been corrected. |
|
EPLAN Platform | User interface |
If several projects were open, the name of the project opened first was always displayed in the graphical preview, regardless of which project was selected in the page navigator. This has been corrected. |
|
EPLAN Platform | Settings |
In the device navigator, texts (displayed DT, etc.) were not converted to upper-case letters during renaming, even though conversion to upper-case was activated in the settings. This has been corrected. |
|
EPLAN Platform | User interface |
Customizing the ribbon in undocked windows resulted in problems. The menu item Customize ribbon is therefore now only available in the EPLAN main window. Exporting and importing a ribbon is now also only possible in the main window. |
|
EPLAN Platform | Connections |
If the connection cross-section was specified with the unit "AWG" at a connection definition point, the check run 005093 erroneously returned a message, even though no values had been entered for the connected terminals in the Terminals: AWG from and Terminals: AWG to properties. This has been corrected. |
|
EPLAN Platform | Labeling |
When outputting labeling data, for example for the report type "Summarized parts list", the data of the mechanical devices were only exported if the setting Apply to entire project was activated. This has been corrected. |
|
EPLAN Platform | Graphical editor |
If the visible device tag of interruption points was filled with subsequent blanks for formatting purposes, the device tags were represented indented differently than in Version 2.9 in the graphical editor. This has been corrected. |
|
EPLAN Platform | User interface |
In property tables (for example in tabular editing) or in the list views of the navigators, it could happen that property values were not inserted correctly when cutting and pasting. This now works again. |
|
EPLAN Platform | Part selection |
If several parts were moved in their position on the Parts tab of the property dialog, this process could take some time under certain conditions. This now takes place faster. |
|
EPLAN Pro Panel | Views |
If in the Unfold dialog the Show drilling pattern property was activated and if cut-outs were located on item edges, these item edges were not always drawn completely in the copper unfolds. This has been corrected. |
|
EPLAN Platform | User interface |
During the search in the property overview and in the Properties tab of the parts management it was not possible to search for the identifying numbers of the properties or for their index values. This has been corrected. |
|
EPLAN Platform | External editing |
The index values of user-defined properties were not displayed in the Selected format elements field in the settings for external editing. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
When moving an item in the layout space, it was possible in the activated design mode that the cursor jumped to an incorrect position after defining the starting point and entering the X, Y and Z coordinates. This has been corrected. |
|
EPLAN Preplanning | Moving PCT loops |
In pre-planning, functions were numbered when moving PCT loops even though the identifiers at the PCT loop had not changed and the identifiers for the functions were not relevant or not valid. This has been corrected. |
|
EPLAN Platform | User interface |
When working with a Chinese keyboard it was not possible to enter Chinese characters into the activated field in the processing mode in the property tables or in the list views of navigators. This has been corrected. |
|
EPLAN Platform | External editing |
If data for external editing was exported and path variables for the project properties $(PROJPROP_<ID>) were used in the Edit externally dialog when specifying the target directory, these path variables were not resolved during the export. This has been corrected. |
|
EPLAN Pro Panel | Model views |
During the copying and pasting of project pages with frozen model views it was possible under certain conditions that the item labeling was missing for model views on the inserted project pages. This has been corrected. |
|
EPLAN Platform | Parts management |
Parts were selected incorrectly in the tree view of the parts management if the superior node was selected in addition to the first selected parts in a node. This has been fixed._. |
|
EPLAN Preplanning | Macros |
When inserting a pre-planning object by means of a macro, the system message "Invalid type conversion" was output. This has been corrected. |
|
EPLAN Platform | Plot frame editor |
If a graphic whose lines intersected the point of origin was to be moved in the plot frame editor via drag & drop, the point of origin was erroneously located at the cursor and EPLAN was terminated unexpectedly. This has been corrected. |
|
EPLAN Platform | Navigators |
If a filter was opened in a navigator (e.g. the "Function designation" filter in the page navigator) and the last entry was selected and moved up with the shortcut key [Ctrl] + [Alt] + arrow key [Up], an unexpected error occurred. This has been fixed._. |
|
EPLAN Pro Panel | Manufacturing Data Rittal - Wire Terminal WT |
During the export of manufacturing data to "Rittal - Wire Terminal WT" a cable connection that had the value "Line" for the Connection: Association property caused an unexpected error message. This has been corrected. In the future, not only cable connections but also phase busbar connections, line connectors and conduit connections will be excluded from the export. |
|
EPLAN Platform | Page navigator |
Display problems could occur in large projects with many pages when browsing through the tree view of the page navigator. The selection jumped back from the last selected page to the originally selected page so that the active page was no longer visible. This has been corrected. |
|
EPLAN Platform | Data exchange with Harness |
During data exchange between EPLAN Electric P8 and EPLAN Harness proD the property Function text (ID 20011) is now also taken into consideration. The exchange file for the export and import of wire harness data (*.hpdex) has been extended accordingly. |
|
EPLAN Preplanning | P&I diagrams |
When copying and pasting P&I diagram pages with linked pre-planning segments into another project, PCT loops were erroneously numbered when the designation of the PCT loops ended with a letter. This has been corrected. |
|
EPLAN | User interface |
If you had created a button in a toolbar using the Check project command and selected a different image for the button, EPLAN had to be restarted. This has been corrected. |
|
EPLAN Platform | Projects |
If the greater-than sign (">") was used in the displayed DT for extended reference identification, it was possible that EPLAN was terminated unexpectedly under certain conditions. This has been corrected. |
|
EPLAN Platform | User interface |
After a Microsoft Office 365 update (e.g. build number 16.0.15028.20160), it was possible that the EPLAN platform automatically restarted after it was exited. This has been corrected. A workaround has been implemented in this EPLAN update. According to information from Microsoft, this issue will be addressed in another Microsoft Office update in the near future. |
|
EPLAN API | Interfaces |
When registering add-ons with integrated API add-ins, problems could occur under certain conditions when customizing the ribbon. This has been corrected. |
|
EPLAN Platform | User interface |
After a Microsoft Office 365 update (e.g. build number 16.0.15028.20160), it was possible that the EPLAN platform automatically restarted after it was exited. This has been corrected. A workaround has been implemented in this EPLAN update. According to information from Microsoft, this issue will be addressed in another Microsoft Office update in the near future. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 99.2.120. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN API | Actions (API) |
The new action partsmanagementapi now makes it possible to export parts under consideration of an existing filter scheme (FILTERSCHEME parameter). |
|
EPLAN Pro Panel | STEP format |
The export of STEP files lead in Version 2022 to some faces not being displayed correctly in the generated STEP file. This has been corrected. |
|
EPLAN Platform | Parts management |
During the import of parts data the values of some properties (for example ERP number) were overwritten even though a protection was specified for these properties in the scheme for the field assignment. This has been corrected. |
|
EPLAN Platform | User interface |
During the import of multiple property arrangements in the property dialog it was possible that this procedure was aborted. This has been corrected. |
|
EPLAN Platform | PDF export |
An infinite loop could occur during the PDF export of large projects. This has been corrected. |
|
EPLAN Platform | User interface |
If an action was performed (such as, for example, selecting pages) in very large projects with an open graphical preview in the page navigator, this could lead to EPLAN only responding again after a few seconds. This has been corrected. |
|
EPLAN Pro Panel | Manufacturing Data Rittal - Wire Terminal WT |
During the export of manufacturing data for the wire fabrication in the "Rittal - WireTerminal WT" format the values for the Dual sleeve prescribed property were exchanged under specific conditions for connections that existed as daisy chains. This has been corrected. |
|
EPLAN Platform | User interface |
If EPLAN Data Portal is arranged as a flyout within the EPLAN Platform, the filter settings used for the import of a part are now kept if the flyout is opened again afterwards and another part is to be imported. |
|
EPLAN Platform | Reports |
If a connection list was output as a report while working with project groups and the name of the project selected in the Connection list (Total) dialog in the Page navigator field, EPLAN was terminated unexpectedly. This has been corrected. |
|
EPLAN Platform | User interface |
When creating a user-defined property configuration for project properties it was possible that EPLAN was terminated unexpectedly. This has been corrected. |
|
EPLAN Platform | Parts management |
If parts data was exported as an XML file and later imported again into a parts database, it was possible that after the import variants without function templates had the same function templates as the first variants of the parts. This has been corrected. |
|
EPLAN Platform | Parts management |
If an SQL server database was set for the parts management, the filter did not work. This has been corrected. |
|
EPLAN API | Methods (API) |
When calling up the Create method from the Component class, the nMacroFromArticleVariant parameter was ignored. This has been corrected. |
|
EPLAN Platform |
If the dialog for printing was called up for a project without pages, EPLAN was terminated unexpectedly. This has been corrected. |
|
|
EPLAN Platform | User interface |
If several texts which contain line breaks were copied from another program (for example Excel) and inserted in EPLAN in multilingual fields of a table (for example for tabular editing, in the dialog Addresses / assignment lists, etc.) these line breaks were displayed as paragraph marks but not interpreted as a line break. This now works again. |
|
EPLAN Platform | Parts management |
During the search for values with blanks in the parts management problems occurred if there was more than one blank in the value. This has been corrected. |
|
EPLAN Platform | Page navigator |
Selecting a page in the tree of the page navigator by entering the first number of the page name now also functions again when the number block of the keyboard is used. |
|
EPLAN Platform | Structure identifier management |
If identifiers were moved by one position by means of the arrow buttons |
|
EPLAN Platform | Block properties |
If a QR code with a specific block property that contains format elements for the page was inserted in a form, the QR code on the generated report pages was calculated incorrectly in the project. This has been corrected. |
|
EPLAN Platform | Parts management |
If the Manufacturer property was used for the tree configuration in the parts management and if it was not the last node in the tree view, not all parts were displayed. This has been corrected. |
|
EPLAN Platform | Graphical editor |
In Version 2022 Update2 the display of the path division in the graphical editor did not work when the command Schematic paths was used. This has been corrected. |
|
EPLAN Platform | Parts management |
If the parts database was used by a further user, the import of parts from EPLAN Data Portal was not possible. This has been corrected. |
|
EPLAN Platform | Parts management |
When exporting parts data in the EDZ or XML format the values of user-defined properties with the field types "Bool", "Integer" or "Decimal" were not exported. This has been corrected. |
|
EPLAN Platform | Parts management |
If the [...] button was used to branch into the Configure properties dialog in the parts management during the selection of a scheme for user-defined properties, an unexpected error message was displayed in the system messages. This has been corrected. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 99.2.120. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Platform | Reports |
For terminals to which an assembly is assigned as a part, no terminal designation has been output in the "Summarized parts list" report when a terminal strip definition was simultaneously available for the respective terminal. This has been corrected. |
|
EPLAN Platform | Reports |
The value of a user-defined property which is defined as a part reference property is now output again in the parts list for terminals to which a broken-up assembly is assigned as a part. |
|
EPLAN API | Methods (API) |
There was a problem during the updating of stored device data when using the part selection via API. This has been corrected. |
|
EPLAN Platform | Projects |
The project was not closed correctly if EPLAN was terminated by the user signing out from their Windows session. This has been corrected. |
|
EPLAN API | Actions (API) |
The import of layers using the parameter TYPE:IMPORT of the action GraphicalLayerTable did not function when one or more layers already existed. This has been corrected. |
|
EPLAN Platform | User interface |
During the import of multiple property arrangements in the property dialog it was possible that this procedure was aborted. This has been corrected. |
|
EPLAN API | Methods (API) |
When calling up the Create method from the Component class, the nMacroFromArticleVariant parameter was ignored. This has been corrected. |
|
EPLAN Platform | Parts management |
If the Procurement property was selected as a further column in the parts management during configuration of the list, no parts were displayed in the list afterwards anymore. This has been corrected. |
|
EPLAN Platform | Projects |
When opening a project with a more recent hotfix / update version, the Modification date property was changed because the internal build number changed due to the update of the project. In the future, this will no longer be the case. The date will only be changed if any data changes due to the update of the project. |
|
EPLAN Platform | Reports |
For terminals to which an assembly is assigned as a part, no terminal designation has been output in the "Summarized parts list" report when a terminal strip definition was simultaneously available for the respective terminal. This has been corrected. |
|
EPLAN API | Methods (API) |
There was a problem during the updating of stored device data when using the part selection via API. This has been corrected. |
|
EPLAN Platform | Navigators |
In the tree of the page navigator you can now select a page again by entering the first number or the first character of the page name. This also applies for the selection of other objects (layout spaces, devices, etc.) in the respective navigators. |
|
EPLAN Platform | Parts management |
The performance when working with the new parts management has been improved (for example with large data amounts, for the filtering by part numbers, etc.). |
|
EPLAN Platform | Projects |
The project was not closed correctly if EPLAN was terminated by the user signing out from their Windows session. This has been corrected. |
|
EPLAN Platform | Parts management |
During a parts data synchronization from a SQL parts database Version 2022 into an older SQL parts database Version 2.9, the values for the property Cable type / type designation (ID 22030) were not updated in the old database but rather deleted. This has been corrected. |
|
EPLAN Electric P8 | Terminals |
If a part number was entered manually in the Edit terminal strip dialog or when editing in tables for a terminal it was possible that the part variant had an undefined value. Now the part variant is set again to the default value "1" in this case. |
|
EPLAN API | Classes (API) |
If a check run derived from the class FunctionVerification was created by means of the EPLAN API, it did not function when no filter was set for the function category. This has been corrected. |
|
EPLAN Platform | User interface |
The selection of a device in the Insert center took place much slower when an SQL database was used for the parts management instead of an EPLAN database. This has been corrected. |
|
EPLAN API | Methods (API) |
When customizing the ribbon via API using the AddIcon method from the RibbonBar class, the images can now not only be transferred as file names of a SVG file but also the complete contents of an SVG file as a character string. |
|
EPLAN Platform | Parts management |
If a differentiation between upper-/lower-case letters was configured for the SQL server which is used for the parts database of the parts management in Version 2022, no connection could be established from the EPLAN Platform to the SQL server. This has been corrected. |
|
EPLAN Platform | Part selection |
If a user-defined tree configuration with multilingual property was used for the part selection, a part which was already assigned to a function was not pre-selected in the tree during the part selection. This has been corrected. |
|
EPLAN Platform | Parts management |
If an accessory list was selected in the Accessories tab of the parts management, only accessory lists could be selected for a further accessory selection, but not parts. This has been corrected. |
|
EPLAN Platform | User interface |
During the export of a user-specifically modified ribbon this was saved as an XML file with the coding "UTF-8". In the process display problems occurred in some languages. This was solved since the XML file is now saved with the coding "UTF-16-LE". To use existing user-specific ribbons you can, for example, convert these in the default text editor (Notepad) into the format "UTF-16 LE". |
|
EPLAN Platform | Edit in table |
Only a limited number of values could be copied from Microsoft Excel and pasted for editing in a table. This has been corrected. |
|
EPLAN Preplanning | P&I diagrams |
If macros with structure segments are inserted in the P&I diagram, the connection between a placeholder object in the macro and the structure segments now remains, in as far as the structure segment were recently inserted and not previously available in the pre-planning of the project. This way the values of structure segments in the P&I diagram can also be changed subsequently by assigning placeholder objects. For assigned structure segments which already existed in the pre-planning, the connection to the placeholder object is removed. |
|
EPLAN Preplanning | Links |
When inserting macros with the "P&I diagram" representation type, existing links between the segments are not inserted as well. This has been corrected. |
|
EPLAN API | Actions (API) |
The import of parts data after external editing using the action XMImportDCArticleDataAction did not work when a graphical editor was opened. This has been corrected. |
|
EPLAN Platform | Block properties |
In the dialog Format for block properties, the two fields Navigation and Preview are now adapted to the size of the dialog. This means that with longer texts you do not have to work with scroll bars anymore to fully read this information. |
|
EPLAN Platform | User interface |
If table cells were copied in the property tables, it was possible that the column headers were copied as well even though they were not marked. This has been corrected. Now the column headers are only copied into the clipboard if they are also marked. As part of this change the contents of the clipboard are now saved in HTML format when copying table cells. This way the column header is also inserted by default when a copied table cell is inserted in Excel. If you want to insert only the text of the table cell, you have to insert the contents of the clipboard as text without formatting by using the "Paste Special" command in Excel. |
|
EPLAN Platform | User interface |
In the Insert center tags with a dot in the name were not saved correctly. This has been corrected. |
|
EPLAN Platform | User interface |
Assignment of user-defined image files when customizing the ribbon When you customize the ribbon and assign actions and/or commands to user-defined command groups, you now also have the possibility to use own image files for these functionalities. The dialog Rename which allows you to assign an image file when customizing the ribbon has been expanded for this purpose with the buttons
|
|
EPLAN Platform | User interface |
User-defined Tooltips and descriptions for actions in the ribbon When customizing the ribbon, a Tooltip and a description can now be specified for actions. To this purpose the Rename dialog for actions should be extended with the corresponding fields. In Version 2022 Update1 the designations of these fields are only displayed in English. |
|
EPLAN API | Methods (API) |
Extension of the class "RibbonCommandGroup" for the assignment of user-defined images New overload functions have been added in the "RibbonCommandGroup" class for the "AddCommand" method which allow you to assign own images (*.svg) to commands in user-defined command groups as well as to add Tooltips and descriptions for actions. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 94.4.50. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Pro Panel | 3D mounting layout |
If multiple layout spaces were copied in a project and inserted into another project using the Clipboard and existing layout spaces were overwritten in the process, it was possible that items such as, for example, a mounting panel were not displayed in a copied layout space even though they were available in the layout space navigator. This has been corrected. |
|
EPLAN API | Properties (API) |
It is now possible to query and specify the field type for user-defined properties in parts management by means of the new property "FieldType" from the class "MDUserDefinedPropertyDefinition". |
|
EPLAN Platform | User interface |
Specific context-dependent commands (such as, for example Image file, DXF / DWG, Hyperlink, QR code of the Insert tab) are not available anymore to customize the quick access toolbar. Because such commands are assigned to different command groups depending on the context (opened editor), problems arose when such a command was added to the toolbar. |
|
EPLAN API | Classes (API) |
If methods from the classes for the ribbon were used in API offline applications ("RibbonBar", "RibbonTab", "RibbonCommandGroup", "RibbonCommand"), an exception was issued. This has been solved. |
|
EPLAN Platform | Macros |
When an individual macro is created using the command Create window macro / symbol macro (shortcut keys [Ctrl] +[ F5]), the macro collection is updated. In the past all macros were checked. To accelerate the macro collection update, the update now only takes place for the new macro. The remaining macros of the macro collection are not checked. |
|
EPLAN API | Scripts |
In scripts you can now also access the parts management and, for example, edit the properties of parts. In the name space |
|
EPLAN Platform | 2D panel layout |
When a device is placed on a mounting panel in the 2D panel layout the dimensions stored at the part are now considered again for the setting Macro and dimensions from parts master data when the macro of the part does not contain the correct representation type. |
|
EPLAN API | Properties (API) |
Using the BasePoint property from the ContextPropertyPlacement class it was previously not possible to specify the respective base point in the property arrangements for part properties and/or part reference properties. This now works. |
|
EPLAN Platform | Part selection |
During the part selection a part can now be transferred again to the property dialog with a double-click. |
|
EPLAN Platform | User interface |
If you jumped to different operating elements and commands in the Backstage view by using the shortcut keys [Shift] + [Tab], it was possible that a command (e.g. Exit) was executed, without the [Enter] key or the [Spacebar] being selected. This has been corrected. |
|
EPLAN Platform | Parts management |
If a hierarchy level with many parts (> 7700) was opened in the tree of the parts management, EPLAN was unexpectedly terminated. This has been corrected. |
|
EPLAN Platform | Part selection |
If block editing was performed for several main functions or connections and a part number was entered manually there, a memory access violation occurred under specific conditions. This lead to the selected part only being entered at the first main function or connection. This has been corrected. |
|
EPLAN Platform | Change of standard |
During the change of standard symbols which were partially outside the plot frame were not taken into consideration. This has been corrected. |
|
EPLAN Platform | Graphical editor |
The graphic at the cursor is now visible again immediately when symbols are inserted by means of shortcut keys (e.g. [F3] for "Angle (down, right)"). |
|
EPLAN Platform | Parts management |
When using an SQL server for the parts database it happened under specific conditions when the parts management was opened that the SQL database was set to the single-user mode and remained in this mode. This has been corrected. |
|
EPLAN Pro Panel | Master data for EPLAN Pro Panel |
The performance when assigning parts data has been improved for the Synchronize devices dialog which is opened during the import of device data. If this procedure takes some time, a progress bar is now displayed. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 93.1.140. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Platform | DXF / DWG interface |
During the DXF export of terminal diagrams an incorrect display of jumpers occurred on the output pages. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
When placing accessory parts, an incorrect placement occurred under certain conditions. This has been corrected. |
|
EPLAN Platform | EPLAN ePULSE |
When inserting macros from the ePULSE EPLAN Data Portal, the correct representation type was not taken into account, but only the macro with the "Multi-line" representation type was inserted. This has been corrected. |
|
EPLAN Platform | User interface |
When repeatedly importing property arrangements in the Configure property arrangements dialog, property arrangements were created multiple times under certain conditions. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
When inserting accessories, 3D macros with only a variant B were ignored. This has been corrected. |
|
EPLAN Platform | User Interface |
Access to EPLAN Cloud Products in the Platform In the new Version 2022 an EPLAN ID which is linked to a company organization is required to use the solutions of the EPLAN platform. A sign-in dialog is now opened when starting EPLAN. There you enter your e-mail address and the password you specified when creating the EPLAN ID. If you do not have an EPLAN ID, click the "Create EPLAN ID now" hyperlink in the sign-in dialog. |
|
EPLAN Platform | User Interface |
The new Insert center for Symbols, Devices and Macros The new Insert center allows you to insert different objects such as symbols, devices as well as window and symbol macros directly via a shared dialog onto project pages or into layout spaces. In addition the dialog provides various quick access possibilities which allow you to accelerate the design stage. |
|
EPLAN Platform | User Interface |
New Setting Option for Light and Dark Design You can now choose between light and dark design for the user interface. To this purpose the user settings for the user interface have been extended with the setting User interface design (command path: File > Settings > User > Display > User interface). |
|
EPLAN Platform | User Interface |
The New Ribbon Commands for the navigators and graphical editors are now no longer selected via menu and toolbars, but by means of a ribbon. This ribbon is similar in functionality and structure to the ribbons known from Microsoft Office products. |
|
EPLAN Platform | User Interface |
New Dialog for Customizing the Ribbon As part of the redesign of the user interface with new elements such as the Ribbon and the Quick access toolbar there is also a new dialog Customize to make user-specific customizations at these elements. |
|
EPLAN Platform | User Interface |
New Dialog for Customizing the Shortcut Keys The specification of shortcut keys is now no longer carried out by means of a settings dialog but while customizing the ribbon or the quick access toolbar. To this purpose you can branch to the new subsequent dialog Customize shortcut keys by using the button [Customize] in the Customize ribbon tab of the Customize dialog. The previous settings dialog has been removed. |
|
EPLAN Platform | User Interface |
Selecting workspaces via a button in the ribbon The selection of a workspace now takes place via a button in the ribbon. By clicking the |
|
EPLAN Platform | User Interface |
Showing the menu bar as a transition help You can have a menu bar with the "old" menus from Version 2.9 shown as a transition help for the new ribbon. |
|
EPLAN Platform | User Interface |
Defining undocked editors as the main working window Previously the pages, layout spaces, etc. were only opened via the popup menu item Open in new window in a docked editor. Now you have the possibility to also define undocked editors as main working windows. The popup menu item Main working window is available to this purpose in the title bar of the respective editor. An editor activated as a main window is highlighted by a blue frame. |
|
EPLAN Platform | User Interface |
Backstage View The solutions of the EPLAN Platform offer the Backstage view as a new feature - the functionality to comfortably edit, back up, organize, print and pass on your projects. You are already familiar with such a Backstage view from Microsoft Office products. |
|
EPLAN Platform | User Interface |
Where do I find my known functionalities in the Backstage view? As part of the redesign of the user interface different functionalities that refer to the work with projects were moved to the Backstage view. |
|
EPLAN Platform | User Interface |
New File Selection and Directory Selection Dialogs In the course of the redesign of the user interface many dialogs in which you select a file or a directory (for example Open project, Open form, Select folder) have been adapted to a modern Windows "look and feel". Opening these dialogs now instead takes place by using the button [...] via the buttons |
|
EPLAN Platform | User Interface |
Optimized Display for Tables As part of this redesign of the user interface the appearance and behavior of the tables has partially changed. To optimize the display the new popup menu item Column width automatic is available in many dialogs, and in some dialogs with property tables (e.g. first tab of the property dialog, Properties tab of the parts management) the new popup menu item Customize row. |
|
EPLAN Platform | User interface |
Changed behavior for the icons in the status bar In the course of the new user interface the behavior of the icons in the status bar has also changed. For example, one click on the |
|
EPLAN Platform | User interface |
Renamed terms in the project structures Several terms which are used in the project structures and structure identifiers have been renamed. The identifier block "Higher-level function" is now called "Function designation" and the identifier block "Mounting location" is called "Location designation". |
|
EPLAN Platform | User interface |
Shortcut keys for inserting now open the Insert center With the familiar shortcut keys [Ins], [Ctrl] + [Ins], [M] and [Alt] + [Ins] you no longer call up the selection dialogs for inserting symbols, macros and devices, but rather the new Insert center with which you can easily insert all these objects into the project by using drag & drop. After opening with these shortcut keys the cursor is located in the search field of the Insert center and you can start immediately with the search. The executed shortcut key determines which folder (Symbols, Devices or Window macros / symbol macros) is displayed after a successful search as directly opened up. |
|
EPLAN Platform | User interface |
Removed symbols navigator In the course of the redesign of the user interface, the symbol navigator has been removed and is now also no longer available as a command. In addition the part master data navigator is only available as a command in the Customize dialog. |
2022 |
EPLAN Platform | User interface |
Changed behavior with drag & drop The behavior has changed for different drag & drop actions. |
|
EPLAN Platform | User interface |
New buttons for displaying the properties In the Property overview dialog you can specify the display of the properties by means of the buttons |
|
EPLAN Platform | User interface |
Changed color settings for project groups In the dialog Settings: Project groups (definition) the standard colors for the coloring of defined project groups were changed so that these colors match both the light as well as the new dark user interface design (command path: File > Settings > User > Display > Project groups (definition)). As part of these modifications only the editor of an opened page / layout space receives a colored border and the tab is not colored anymore. |
|
EPLAN Platform | Projects |
Basic Projects instead of Project Templates Projects are now only created on the basis of basic projects (*.zw9). Basic projects offer the advantage that they amongst others also contain master data (for example forms and symbols) or referenced data (for example image files) stored in the project. The creation of projects on the basis of project templates (*.ept and *.epb) is not supported anymore. Project templates can no longer be selected or created. Accordingly the Create project template dialog has been removed. In addition, the Template field has been renamed to Basic project in the Create project dialog. |
|
EPLAN Platform | Projects |
Updating the Project Databases As part of miscellaneous extensions and optimizations, the project databases have been changed in Version 2022. This has the effect that new projects are essentially created with new project databases. |
|
EPLAN Platform | Projects |
Removed menu item "Publish" In the course of the redesign of the user interface, the menu item Publish has been removed and is now also no longer available as a command. The associated dialogs have also been removed (dialogs Publish and Settings: Publish). EPLAN eVIEW is available for the review and commenting of EPLAN projects in an Internet browser. |
|
EPLAN Platform | Projects |
Removed menu items for comments The menu items for redlining of projects via PDF comments have been removed (Comments navigator, PDF comments) and are now also no longer available as commands. EPLAN eVIEW is available in the cloud for an improved redlining workflow. |
|
EPLAN Platform | Connections |
Predefining Functions as the Source / Target of the Connection You can now also determine the source and target of connections manually. To this purpose use the new Source / Target connection property at the connected functions. This property is available to you in the property dialog of functions in the subsequent dialog Connection point logic. |
|
EPLAN Platform | Connections |
Extended Settings for the Reset Area of the Connection Numbering In the settings for the connection numbering you have the possibility to specify a reset range for the counter. The command path to these settings is: File > Settings > Projects > "Project name" > Connections > Connection numbering. Depending on the criteria specified there, the counter starts again with the start value if the page or a structure identifier, for example, has changed. Now you additionally have the possibility to have the counter reset when the schematic path changes. |
|
EPLAN Platform | Parts Management |
Revised Parts Management The previous database technology for the parts management was outdated and has been revised for the current version. There are now new parts databases in the internal EPLAN format *.alk with the associated directory *.adb. These databases replace the old Access databases (*.mdb). Because of the changed table structure, new SQL databases have to be used when SQL Server is used. |
|
EPLAN Platform | Parts Management |
Data Exchange of Parts Data via External Editing To exchange data it is now possible to use external editing in the parts management. To this purpose the new menu item Edit properties externally with the two submenu items Export data and Import data is available in the parts management below the [Extras] button. |
|
EPLAN Platform | Parts Management |
Migration of Old Parts Databases Because of a changed database technology, parts databases from older EPLAN versions (Version 2.9 or older) cannot be used in the current version. However, it is possible to transfer "old" parts databases into new databases in the parts management. To this purpose you can select old databases in the Settings: Parts (user) dialog during the selection of the database source. |
|
EPLAN Platform | Parts management |
Removed part settings In the course of the restructuring of the parts management, the user-specific setting Use SQL Server full-text search that is no longer needed has been removed from the Settings: Parts dialog. In addition the two settings Function definition library for template selection and List / tree sorting have also been removed in the following dialog Settings: Parts management. |
|
EPLAN Platform | Parts management |
Removed connection to the Festo product catalog The connection to the Festo product catalog has been removed in the EPLAN platform. Therefore it is no longer possible to open the Festo product catalog in the new parts management. The popup menu item Festo shopping basket has also been removed in the Device list dialog. |
|
EPLAN Platform | Parts management |
Removed functionalities for prices and currencies The two functionalities Calculate prices and Convert currencies have been removed in the course of the redesign of the parts management. Therefore the two menu items Prices and Currencies are not available below the [Extras] button. The two menu items Space requirement and Update search index are also removed in the course of redesign. |
|
EPLAN Platform | Parts management |
Dialog for free properties No tab, but rather a dialog, is now available in the parts management for the maintenance and management of free properties. This dialog is accessed from the tab User-defined properties by using the button [Free properties]. |
|
EPLAN Platform | Parts management |
Downloading of parts data only via the new EPLAN Data Portal Solely the EPLAN Data Portal is now available as the exchange portal for downloading parts data. In the course of this change the old EPLAN Data Portal has been removed from the user interface of the EPLAN Platform (Dialog Settings: Data Portal, popup menu item Update via Data Portal in the parts management, etc.). |
|
EPLAN Platform | Parts management |
Extended configuration of the tree view By means of a configuration of the tree view you can specify in the parts management which additional information is to be shown to you for quicker identification of parts. In the new version such a configuration is not only possible for parts but for other objects (accessory list, drilling pattern, etc.) as well. In addition further information can now also be shown for the part variants. To this purpose the Configure representation dialog has been extended with the configuration possibility for objects such as "part accessory list", "part drilling pattern", etc. and for the "part variant". |
|
EPLAN Platform | Parts management |
New check runs for checking ERP number at parts The ERP number entered at a part must be unique as the part number of an external ERP system. Even though the ERP number is checked for uniqueness during the entry and import of parts data, same ERP numbers are still possible at different parts or variants as a result of editing via the EPLAN API. The new check run 501021 in the message class 501 "Part master data" is available to find the relevant part. In addition it is thus also possible that different ERP numbers are available for the variants of a part. The new check run 501036 is available to find the differences between the variants of a part. |
|
EPLAN Platform | Parts management |
"Generate part" takes subdevices into consideration The Generate part command allows you to create a part from the schematic data. The subdevices are now also considered and the device data of the subdevices is transferred into the part. |
|
EPLAN Platform | Parts management |
Renamed an new properties The Macro property which was previously placed on the Technical data tab has been renamed to Schematic macro. This means that this property can be more easily differentiated from the property Graphical macro where, for example, 3D macros for the layout space are placed. Both properties are now located on the Properties tab. The Schematic macro property in the Data hierarchy level and the Graphical macro property in the Mounting data hierarchy level. |
|
EPLAN Platform | Parts management |
"Function templates" tab for mechanical parts as well For parts from the "Mechanics" generic product group you also have the Function templates tab available instead of the Function definition tab. For a mechanical part you can only specify one function template here. Accordingly, only one line with the columns Function definition and Item is available for such a part. This line can neither be deleted nor can other lines with function templates be added. |
|
EPLAN Platform | Parts management |
Changed classification of a part in a product group The classification of a part into "Generic product group", "Product group" and "Product subgroup" is now carried out with the new property Product grouping (ID 22367). In this property from the "General" hierarchy level the classification is shown like a directory path in a breadcrumb trail (e.g. "Electrical engineering > Cable > General"). To change the classification, click the Properties tab for the property Product grouping in the column Value and on [...]. From the drop-down list with the product groups double-click to select the desired product subgroup (e.g. "General"). After application of the modifications the new product grouping is also displayed for the hierarchy levels in the tree. |
|
EPLAN Platform | Parts management |
Renamed menu item "Summarize function templates" The menu item Sum up function templates below the [Extras] button has been renamed to Summarize function templates. With this menu item you can summarize the function templates of the individual parts for assemblies and modules and enter them at the assembly / module. |
|
EPLAN Platform | Parts management |
Filtering for data of the function templates In the parts management it is now possible to filter the parts according to function definitions and other data of the function templates (e.g. technical characteristics). For this reason the criteria selection of the filter has been expanded with the following entries:
|
|
EPLAN Platform | Part selection |
Change for the project-specific part selection At a project-specific part selection, only those parts are offered which are stored in the project. If such a part selection was set in the Settings: Part selection dialog in the "Project" option, an mdb database was previously created as a file for the parts stored in the project. This file is not required anymore. When using a project-specific part selection you now work directly in an internal project parts database with the parts stored in the project. |
|
EPLAN Platform | External Editing |
Changed File Format During the Export and Import of Excel Files During the import and export of Excel files, the Excel file format *.xlsx is now used as the default. Restrictions exist with the old Excel file format *.xls with regard to the amount of data (for example, number of columns and lines). |
|
EPLAN Platform | Graphical editor |
Change of graphical display to a new technology The quality of the representation of objects on pages has been improved decisively by a change to a new technology in the graphical output in the 2D section: The speed while drawing, marking and selecting components, graphical elements and texts has increased significantly. Thanks to the improved graphical representation the texts are now easier to read. Zooming and moving of schematic objects has also been significantly increased. |
|
EPLAN Platform | Graphical editor |
Removed scroll bars The scroll bars in the graphical editor and the associated user-specific setting Display scroll bars have been removed. An enlarged or reduced window pane of an editor can still be conveniently moved with the mouse (mouse wheel or middle mouse button). |
|
EPLAN Platform | Page navigator |
Removed manual page sorting The possibility to specify manual sorting of the pages for list views has been removed. The popup menu item Manual page sorting in the page navigator, the subsequent dialog by the same name as well as the associated project-specific setting in the Settings: Pages dialog are now not available anymore. |
|
EPLAN Platform | Settings |
Settings in the Backstage view The settings of the EPLAN Platform can now be accessed via File > Settings in the Backstage view. |
|
EPLAN Platform | Settings |
Removed user-specific settings for graphical editing In the user-specific dialog Settings: 2D, the settings Minimum font size and Display crosshairs when placing symbols and macros have been removed (Command path: File > Settings > User > Graphical editing > 2D). |
|
EPLAN Platform | Settings |
Removed settings for the terminal server As a result of the improved graphical display the optimization settings for the terminal server are now superfluous and have been removed (Command path: File > Settings > Workstation > Display > General). |
|
EPLAN Platform | Settings |
Additional connection tests for EPLAN Cloud products Some of the URLs required for EPLAN Cloud products are now additionally checked in the Connection test tab of the dialog Settings: Internet connections. |
|
EPLAN Platform | Settings |
Removed setting "Zoom in text" In the dialog Settings: Compatibility the setting Zoom in text has been removed (Command path: File > Settings > Projects > "Project name" > Management > Compatibility). |
|
EPLAN Platform |
Printing with preview in the Backstage view Printing project pages now takes place via the Print Backstage view. As part of these modifications the Print dialog has been revised. The print preview has been integrated into the Print dialog and is not called up anymore as a separate dialog. In addition only those pages are now displayed in the print preview which are also printed. |
|
|
EPLAN Platform |
Printing of attached documents in the Backstage view Printing of attached documents now takes place via the Print Backstage view. Accordingly the menu item Print attached documents has been removed and is now also not available as a command anymore. The Print attached documents dialog has been redesigned and renamed into Select attached documents. |
|
|
EPLAN Platform | Translation |
Number of placeholders in the keywords increased to 100 The number of the placeholders that can be used in the keywords of the dictionary has been increased from previously 10 to 100 now. |
|
EPLAN Platform | Translation |
Double-clicking the icon opens the "Multilingual input" dialog Since Version 2.9 multilingual entry fields were by default identified with a preset icon ( |
|
EPLAN Platform | Revision control |
Identification of pages with deleted objects as "Draft" If an object on a page is deleted in a revision project, the page is now identified as "Draft", irrespective of the project setting While deleting create deletion markers and list deleted pages. This page can thus be completed and provided with a revision index. |
|
EPLAN Platform | User-defined properties |
Other usages for user-defined part properties The user-defined properties for this part are now also available to you in the parts management for the configuration of the tree view and list view. In addition these user-defined properties can now also be used as filter criteria for the parts pre-filtering. Furthermore these user-defined properties can now also be selected in the bill of materials and in the 3D mounting layout navigator as filter criteria in the Criteria selection dialog below the hierarchy level "Part". |
|
EPLAN Platform | User-defined properties |
User-defined part properties without definition If you import parts from Version 2.9 with assigned user-defined properties for parts or schemes for the user-defined properties, it is possible that you will add user-defined properties to the parts database which are not defined in the Configure properties dialog. A corresponding message is displayed in the system messages in this case. |
|
EPLAN Platform | Message management |
Additional column for PLC connection points in the message management In the Message management - <Project name> dialog you can now show the Connection point designation (with plug designation (automatic)) property as an additional column. This makes it easier to find PLC connection points that are reported by the message class "PLC / Bus". If a PLC connection point, bus port or device connection point was reported as faulty during the check, the combination of plug designation and connection point designation of this connection point is displayed here. |
|
EPLAN Platform | DXF / DWG Interface |
Extension in the selection dialog In the DXF / DWG file selection dialog, that is for example opened during the DXF / DWG import of pages, the "AutoCAD drawing files (*.dxf, *.dwg)" entry is now additionally available for the File type field. During the selection of this entry, both DXF and DWG files are displayed in the selection dialog. |
|
EPLAN Platform | DXF / DWG Interface |
Added format versions for the export scheme In the dialog Settings: DXF / DWG export and import the AutoCAD formats "AutoCAD 2020" and "AutoCAD 2021" are now available in the Export tab in the drop-down list Format version. |
|
EPLAN Platform | Data backup |
Removed functionalities for sending e-mails The functionalities for sending projects as e-mails have been removed from the user interface. Accordingly the menu item Send by e-mail has been removed (for example in the project management), and is now also not available as a command anymore. Even when backing up projects and master data as well as different exports (DXF / DWG, PDF, etc.) the E-mail option is no longer available as a storage or export medium. |
|
EPLAN Platform | Data backup |
Removed functionality for the project packing The packing of projects in order to reduce storage space is generally not required anymore. The Pack menu item in the project management has been removed accordingly and is now also not available anymore as a command in the EPLAN Platform. As a rule all projects and other data are still packed during the EPLAN data backup. Packed projects (for example from previous EPLAN versions) are now automatically unpacked while opening a project in the Backstage view. |
|
EPLAN Platform | Data backup |
New dialogs for backing up and restoring master data To back up and restore Master data one dialog is now available instead of numerous menu items and dialogs. These new dialogs are located in the Backstage view Extras (command path: File > Extras > Command group Organize > Master data). The master data to be backed up and restored, such as, for example, "Parts data", "Basic projects", "Forms", etc. is selected in the two dialogs above the drop-down list Master data type. The other fields and settings are otherwise familiar to you from the previous dialogs for backing up and restoring from previous versions. |
|
EPLAN Platform | Data backup |
Removed settings for default settings of the data backups The default settings for the data backup of projects became superfluous since projects are now only created on the basis of basic projects (*.zw9) and the affected settings are contained in the basic projects. Accordingly, the Settings: Projects dialog in the user settings has been removed. |
|
EPLAN Platform | Automated processing |
Descriptions for actions with the same name You can now store informative descriptions for the selected actions in a scheme for the automated processing. This is of interest if you want to perform multiple similar actions for a scheme (for example multiple actions for the output of labeling data for different output types). To this purpose a new Description column is now available for the table with the selected actions in the Settings: Automated processing dialog. The text entered here is additionally displayed in the Run: Automated processing dialog. |
|
EPLAN Platform | Automated processing |
Input option for the name of the backup file Previously it was not possible to specify the name of the backup file for the action "Back up data" in automated processing. The project name was always used as the backup file name. To be able to specify the name, the field Backup file name including a subsequent dialog for file selection has been added to the dialog Back up data. |
|
EPLAN Platform | Cleaning up a project |
Renamed and removed settings for the project correction In the course of the introduction of the Backstage view the functionality Correct project has been renamed to Clean up project. |
|
EPLAN Platform | Project compression |
Summarized functionalities for compressing and reorganizing projects In combination with the introduction of the Backstage view the functionalities for compressing and reorganizing projects were combined. The menu item Reorganize has been removed accordingly in the project management. The reorganization now takes place during the project compressing. To this purpose the dialog Settings: Compression below the hierarchy level Reorganize project has been extended with the setting Advanced mode for the correction of the project database. Furthermore the filter in the Compress project dialog has been removed. |
|
EPLAN Platform | Project compression |
Removed compressing settings In the case of the compressing of projects the two hierarchy levels Symbols and Comments with the settings located below have been removed from the dialog Settings: Compression (check boxes Remove unused alternative symbol variants, Remove unused symbol variants and symbols and Remove comments). |
|
EPLAN Platform | Help system |
New layout of the help system In accordance with the redesign of the user interface, the layout of the help system has additionally been customized for this version. The help has been designed more reader friendly by using a larger font size and uniform formatting of elements such as notes and tips. |
|
EPLAN Platform | Macros |
Removed graphical macro selection and insertion of macros using drag & drop Macros are now inserted by means of the new Insert center. In the course of this extension the Graphical macro selection as well as the associated settings have been removed from the user interface. Inserting macros from the macro navigator via drag & drop and the associated popup menu item Insert macro in this navigator have also been removed. |
|
EPLAN Platform | 2D panel layout |
Changed default setting for the application of the dimension data Numerous feedbacks have shown the demand to change the settings for the default 2D panel layout setting Macro and dimensions from parts master data in the available default setting. Therefore the Macro from parts master data option is now set as a default for the application in the Settings: 2D panel layout dialog. With this option the macro entered in the part is placed using its original dimensions. |
|
EPLAN Electric P8 | Cables |
Page-oriented Determination of Cable Source and Target Source and target of a cable are determined according to specific rules in EPLAN from the DTs of the functions that are connected to the individual cable connections. Alternatively to this, source and target of a cable can now also be determined through the source and target of the cable connections. The new project setting Determine source and target of the cables via the cable connections is provided to this purpose. |
|
EPLAN Electric P8 | PLC |
Structure of PLC Addresses for Numbering with PLC Data In the settings of the format for numbering with PLC data, you can access individual components of the PLC address. The address is broken down into different levels. In the past the individual levels were identified by means of separators. Now the address format that is set in the PLC-specific settings is evaluated for the structure of the PLC addresses. |
|
EPLAN Electric P8 | PLC |
Extensions for the PLC Data Exchange in the AutomationML AR APC Format Version 1.2.0 PLC data exchange is possible for different PLC manufacturers in AutomationML format. Different variants exist in the AutomationML format depending on the respective usage. The " |
|
EPLAN Electric P8 | PLC |
Automatic Generation of the Start Addresses of PLC Cards The start addresses of the PLC box can now be automatically generated by means of the data length entered there. The new Generate start addresses of the PLC cards dialog is available to this purpose. |
|
EPLAN Electric P8 | PLC |
Additional columns for the assignment list In the Addresses / assignment lists dialog you can now show further properties of PLC connection points and PLC boxes as columns in the assignment list, such as Position / (slot / module) (indirect), PLC card is placed on rack ID (indirect), Plug designation (automatic) etc. This makes it clear to which PLC card an I/O connection point belongs and on which rack and slot / module this PLC card is located. |
|
EPLAN Electric P8 | PLC |
Extended filter possibilities of the assignment list The filter possibilities in the Addresses / assignment lists dialog have been extended. When filtering the assignment list, many other properties are now possible as filter criteria, such as Data type, Channel designation, Direction, Symbolic address etc. This way the assignment list can for example be filtered for inputs via the Direction property. |
|
EPLAN Electric P8 | PLC |
Customizations for the bus system "IO Link" for PLC data exchange The bus system " |
|
EPLAN Electric P8 | PLC |
New bus systems The following Ethernet-based bus systems are now also available at bus ports: " |
|
EPLAN Electric P8 | PLC |
Simplified selection of the format when importing PLC data During the import of PLC configuration files the format of the import file is now automatically detected for many common PLC configuration programs and does not have to be selected manually anymore. A file selection dialog is now displayed before the Import PLC data dialog. Depending on the PLC configuration file selected, the matching format is then preset in the Format of import file field. |
|
EPLAN Electric P8 | PLC |
Extension for address-oriented view of the PLC navigator In the address-oriented view of the PLC navigator a preset icon |
|
EPLAN Electric P8 | PLC |
Display of the function text in the rack-oriented view of the PLC navigator In the rack-oriented view of the PLC navigator you can now additionally display the function text of the PLC box at the rack. To this purpose the new "Function text: PLC box (rack-oriented view)" object is now available in the Configure representation dialog. For this object click [...] in the Block format field to specify the desired format and, if necessary, a separator. In the Format dialog, double-click in the list of available format elements on the entry "General function" and select the "Function text (automatic)" entry in the subsequent dialog Format: Block property. |
|
EPLAN Electric P8 | PLC |
New properties for the safety addresses The property Safety address (ID 20439) has been renamed into Safety address: Target. In addition three more properties are now available for safety addresses: Safety address: Source (ID 20615), Safety address: Upper value (ID 20616) and Safety address: Lower value (ID 20617). |
|
EPLAN Electric P8 | PLC |
New property "Standard gateway" At bus ports the new property Standard gateway (ID 20613) is now available. Here you can enter the standard gateway (for example, a router) to which bundles that cannot be directly delivered within a LAN are sent. To differentiate, the old properties for the standard gateway, that are only available for reasons of compatibility to older EPLAN versions, are identified with the supplement "Do not use anymore". |
|
EPLAN Electric P8 | PLC |
Removed entries for outdated PLC interfaces As of Version 2022 some outdated interfaces to the PLC configuration program are not supported anymore since the manufacturers are changing over to the new AutomationML standard. Therefore the associated entries are no longer available during the export and import of PLC data: |
|
EPLAN Electric P8 | PLC |
Network properties can only be edited at bus ports Network structures and bus interfaces are defined via the bus ports. The entry of bus data at the PLC box is not required. Therefore the following properties can only still be edited at the bus ports: Physical network: Bus ID / item number (ID 20311), Physical network: Bus ID / item number 2 (ID 20386), Physical network: Name (ID 20413), Subnet mask (ID 20446), Bus system (ID 20308). |
|
EPLAN Electric P8 | PLC |
New "REAL" PLC data type The " |
|
EPLAN Electric P8 | Message management |
New check run for blanks in symbolic addresses By means of the new check run 0041130 from the message class 004 "PLC / bus" you can now check whether the symbolic address of a PLC connection point contains a blank, a tabulator or a line break. According to standard IEC 61131-3 these characters are not permitted in a symbolic address. |
|
EPLAN Electric P8 | Terminals |
Alignable accessories are always visible The alignable accessories of terminals and terminal strips are now always visible in the dialog Edit terminal strip and cannot be hidden. Accordingly the popup menu item Alignable accessories visible has been removed. |
|
EPLAN Pro Panel | Manufacturing data Copper DXF |
Transferring DXF Data for Copper Rails to the During the copper DXF export of manufacturing data for the machining it is now also possible to transfer DXF data for busbars made of copper to the |
|
EPLAN Pro Panel | Manufacturing data Rittal - RiPanel Processing Center |
New Interface for the Manufacturing Data Export to There is now an interface for the export of manufacturing data to the manufacturing planning and control program |
|
EPLAN Pro Panel | Manufacturing data Rittal Configuration System |
New Interface for Data Exchange of Rittal Parts Data with the A new interface is available for the bidirectional data exchange of Rittal parts data with the configurator software |
|
EPLAN Pro Panel | 3D mounting layout |
New block properties for 3D part placements When determining the format for block properties the new format element "3D part placement" is now available in the Format dialog for functions below the "Function" entry. By means of this format element you can access properties of the 3D part placement during the definition of block properties (for example Layout space description, Item designation, etc.). |
|
EPLAN Pro Panel | 3D mounting layout |
Busbar supports snap onto the guide rails Placement of busbar supports on user-defined rails has been made easier. The busbar supports now also snap onto the guide rail of a user-defined rail. |
|
EPLAN Pro Panel | 3D mounting layout |
Placement options available when inserting locked areas When inserting locked areas (restricted placing areas, restricted cut-out areas) the Placement options dialog is no longer available. As is usual with other placements in the 3D mounting layout, the placement options can be called up during the insertion by using the familiar popup menu item Placement options or via the shortcut key [Ctrl] + [W]. You can determine the distance between cursor and placement point for the start and / or end point of a locked area by means of the fields available here Offset X and Offset Y. |
|
EPLAN Pro Panel | 3D mounting layout |
Removed check box "Write back dimensions to part" Before placing parts (for example by inserting as a device from the Insert center) you can manually enter the part dimensions of the parts (for example via the Insertion as a device function from the Insert center) to be placed in the Dimensions dialog. Writing back of the entered values in this dialog into the new parts management is not possible anymore. For this reason the Write back dimensions to part check box has been removed. |
|
EPLAN Pro Panel | 3D mounting layout |
Improved performance when rotating the viewing angle and when moving When rotating the viewing angle or when moving the selected items in a layout space associated multi colored part placements are now displayed during the action with one single color for a short time. This way the performance could be improved during the rotation of the viewing angle and while moving. |
|
EPLAN Pro Panel | 3D mounting layout |
Renamed locked area for cut-outs The functionality Restricted drilling area has been renamed to Restricted cut-out area since these locked areas prevent any type of cut-out. In the ribbon you can insert such locked areas with the following commands Tab Insert > Command group Locked areas > Cut-out. |
|
EPLAN Pro Panel | Routing connections |
Improved routing for PLC devices If PLC devices were placed on bases with the same DT, problems with the routing occurred because connection points existed double in the connection point patterns. A connection point pattern was generated from the function templates at the part of the PLC device, a connection point pattern was stored at the part of the respective base. If multiple items are now placed that have the same DT, a check is carried out whether one of these devices has a connection point pattern. If this is the case, no connection point pattern is generated from the function templates of the other parts anymore. Therefore routing in the layout space is now also possible for such PLC devices. |
|
EPLAN Pro Panel | Model views |
Excluding model views for the output of labeling data for enclosure legends The Suppress generation of the enclosure legend property in the model views now also has an effect on the output of the labeling. If the check box is activated, the respective model view is not taken into consideration during the output of the labeling for the report type "Enclosure legend". |
|
EPLAN Pro Panel | Automated processing |
Automatic NC export of DXF files With automated processing the manufacturing data for machining at NC machines can now be automatically exported as DXF files. To this purpose the new "NC DXF" action is available to you in the Settings: Automated processing dialog. |
|
EPLAN Pro Panel | Manufacturing data EPLAN Smart Wiring |
Only required schematic pages exported During the export of manufacturing data for EPLAN Smart Wiring only the required schematic pages are now exported into an EPDZ file. |
|
EPLAN Pro Panel | Manufacturing data EPLAN Smart Wiring |
Extension of the export data with connection properties To receive a better overview of the wirings in EPLAN Smart Wiring, the values of the two connection properties Potential type (ID 31006) and Potential value (ID 33003) are now exported in addition. |
|
EPLAN Pro Panel | Manufacturing data Rittal - Perforex / Secarex |
New setting for the export scope when exporting for Rittal - Perforex Both export interfaces for Rittal - Perforex do not only output data for machining of housings and flat parts to the respective Perforex system but also data for cutting wire ducts, mounting rails and C horizontal rails to the Rittal Secarex AC 18 cutting center. You now have the possibility to specify the export scope in both exports. To this purpose the drop-down list Extent has been added to the respective General tab in the dialogs Settings: Export Rittal - Perforex BC / Secarex and Settings: Export Rittal - Perforex LC / Secarex. With this you determine whether corresponding data shall only be transferred to Rittal - Perforex, only to the Rittal Secarex AC 18 cutting center or to Rittal - Perforex and the Rittal Secarex AC 18 cutting center. |
|
EPLAN Preplanning | Creation of the Detail Planning |
Influencing Page Names when Inserting Page Macros A new setting is now available in order to influence the page names of the generated pages when placing page macros from the pre-planning navigator. To this purpose the general settings dialog for the pre-planning has been extended with the check box Keep page names when inserting page macros (command path: File > Settings > Projects > "Project name" > Pre-planning > General). |
|
EPLAN API | Methods (API) |
Delete unused structure identifiers The new |
|
EPLAN API | Methods (API) |
New method for flipping placed objects Through a new overload of the |
|
EPLAN API | Methods (API) |
Switching the SQL Server database for the dictionary The new method |
|
EPLAN API | Methods (API) |
Switching over an SQL Server database for project management The new |
|
EPLAN API | Methods (API) |
Free Routing of Connections Through a new overload of the |
|
EPLAN API | Methods (API) |
Closing an opened page The new method |
|
EPLAN API | Classes (API) |
New class for the connection category By means of the new class |
|
EPLAN API | Actions (API) |
New parameters for the action "Edit" If a project is opened with the parameter |
|
EPLAN API | Methods (API) |
Creating a new project management database The new |
|
EPLAN API | Actions (API) |
Storing Subprojects The |
|
EPLAN API | Methods (API) |
Extended method "GenerateProject" During "Generate project reports" with the |
|
EPLAN API | Properties (API) |
Listing user-defined layers of a macro The |
|
EPLAN API | Properties (API) |
Requesting or specifying a new property "Source / Target" The IsSourceOrTarget property is now available in the Pin class. This allows you to request the new connection property Source / Target via the EPLAN API as well or to manually specify it. |
|
EPLAN API | Actions (API) |
Determining the currently selected layout space You can now also determine the currently selected layout space by means of the |
|
EPLAN API | Properties (API) |
Determining functions output by a report You can now determine which functions of a specific function-related report are output by using the new property |
|
EPLAN API | Properties (API) |
Determining a connection point pattern at the part You can now determine which connection point pattern is stored at a part by means of the new property |
|
EPLAN API | Properties (API) |
Determining or changing the rotation angle or offset of 3D objects You can now determine the rotation angle or the coordinates of an offset at 3D objects in a layout space by means of the new |
|
EPLAN API | Methods (API) |
New methods because of the removal of the e-mail functionality For the methods |
|
EPLAN API | Methods (API) |
Obsolete method for publishing projects In the current version the menu item Publish as well as the associated dialogs for publishing projects have been removed from the EPLAN Platform. In the course of this redesign the |
|
EPLAN API | Methods (API) |
Specifying the record type when creating a stored part If a stored part is created for a project by means of the |
|
EPLAN API | Classes (API) |
New class for the change of standard By means of the new class |
|
EPLAN API | Actions (API) |
Extended export of the missing-word list The |
|
EPLAN API | Methods (API) |
New method to place functions The new |
|
EPLAN API | Methods (API) |
New method to transfer a selection list In the |
|
EPLAN API | Classes (API) |
The new ribbon in the EPLAN API The selection of the commands for the navigators and graphical editors in the user interface of the EPLAN Platform now takes place by means of a ribbon. The following four new classes are available in the namespace
As in the user interface. you can only add own commands to a user-defined command group. You can export and reimport a user-customized ribbon by means of the two new actions The classes that have become superfluous for the menu bar and the toolbars as well as the associated actions for the toolbars were identified as outdated ( |
|
EPLAN API | Actions (API) |
Export and import of parts data via external editing By means of the new action |
|
EPLAN API | Methods (API) |
New method to filter parts The |
|
EPLAN API | Methods (API) |
Determining filtered parts in the parts management The |
|
EPLAN API | Methods (API) |
New methods for exporting and importing parts data The export of parts now takes place via the |
|
EPLAN API | Properties (API) |
Property for the selection of the parts database By means of the property |
|
EPLAN API | Methods (API) |
Outdated methods for the parts management A separate API has been created for the new parts management of the EPLAN platform. In the course of this change methods from the class |
|
EPLAN Platform | Master Data |
Master Data: Symbols This section provides information about the new symbols that are available to you in the master data as of the current version. |
|
EPLAN Platform | Master Data |
Master Data: Plot Frames and Forms This section provides information about the most important modifications for the plot frames and forms. |
|
EPLAN Platform | Master Data |
Master Data: Identifiers In the Suggested identifiers dialog an identifier set for the standard IEC 81346-2 which considers the modifications of Version 2019 is now also available. A new IEC 81346-2:2019 column was added correspondingly to the dialog. (The command path for this dialog is: Tab Master data > Command group Symbols > Identifier sets.) |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 92.0.260. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Platform | Placeholder objects |
Apart from the (visible) DT, the properties Name (visible) (ID 20002) and Name (full) (ID 20001) for terminals / plugs / device connection points also contain the terminal designation / plug designation or connection point designation. If only the DT component (e.g. X1) is assigned as values to these properties in placeholder objects, automatic numbering of the terminal / plug or connection point designation now takes place again - when a macro with corresponding placeholder object is inserted. (This is the same behavior as before Version 2.8.) If the DT component and the additional name element are assigned to the properties in the placeholder object (e.g. "X1:17"), the additional name element is not numbered and the name is inserted as specified. |
|
EPLAN Platform | Reports |
Specific values were not output in a terminal diagram when the reports for a terminal were divided by a line break. This has been corrected. |
|
EPLAN Preplanning | Reports |
Parts lists can now also be manually placed on pre-planning pages as embedded reports. |
|
EPLAN Platform | DXF / DWG interface |
During the DXF / DXW import, faulty elements in the files are now ignored and no longer result in the cancellation of the import. The faulty elements are logged in the system messages. |
|
EPLAN Platform | Messages |
Check run 005065 has been extended. A message is output when the "Function definition" (ID 20026) property differs at the different representation types of a connection. |
|
EPLAN Platform | Labeling |
During the output of labeling data for the report type "Terminal diagram" an unexpected error message occurred during the usage of a special Excel template which prevented the further export. This has been corrected. |
|
EPLAN Platform | Settings |
After a connection test in the Settings: Internet connections dialog it was possible that the icons in the "Status" column were dynamically magnified in an undesired way. These have been corrected. |
|
EPLAN Platform | Navigators |
If an object was marked and edited in an undocked navigator (for example the property dialog was opened), the marking subsequently no longer existed in the navigator. This has been corrected. |
|
EPLAN API | Methods (API) |
For the "CreateProject" method from the "ProjectManager" class, the error message that occurs when the method was called with an outdated basic project has been improved. |
|
EPLAN Platform | Graphical editor |
The objects covered with a fill surface in the graphical editor were partially still visible. This has been corrected. |
|
EPLAN Platform | Connections |
When Interconnecting devices between direct connection points no direct connections were generated for individual connections but rather connections with the function definition "Conductor / wire". This has been corrected. The function definition of the generated connection is now accepted by the multi-line connection point of the source. |
|
EPLAN Pro Panel | Manufacturing data NC DXF |
Polylines were output incorrectly during the NC DXF export. This has been corrected. |
|
EPLAN Platform | Connection numbering |
During connection numbering the manual sorting sequence of the pages is now taken into consideration when it is relevant for the set format. |
|
EPLAN Pro Panel | 3D mounting layout |
Multi-line texts which had the "Middle center" setting for both the alignment and the base point in the property arrangement were displayed slightly offset in the layout space. This has been corrected. |
|
EPLAN Platform | Graphical editor |
In specific cases targets of interruption points were not found, if the search extends over multiple interruption points. This has been corrected. |
|
EPLAN Platform | DXF / DWG interface |
During the export of pages as DXF files and usage of the default scheme it was possible that specific symbols were exported several times. This has been corrected. |
|
EPLAN Platform | Labeling |
During the output of the labeling for the "Cable diagram" report type no values were output during the selection of indexed part properties for the source and target part at the "Type number" format element. |
|
EPLAN Platform | Messages |
After aligning and formatting connection definition points, the check run 005035 also reported connection definition points which were located on an individual connection. This has been corrected. |
|
EPLAN Platform | Placeholder objects |
When assigning value sets the property arrangement specified for a symbol in the placeholder object was not applied. This has been corrected. The symbol (variant) and the property arrangement can now be specified simultaneously via a placeholder object. |
|
EPLAN Platform | Reports |
During the report of a terminal diagram a problem occurred with the display of further layers during the display of jumpers for multi-level terminals. This has been corrected. |
|
EPLAN Platform | Plot frame editor |
When specific plot frames were opened in the plot frame editor, both the selected plot frame and the plot frame of the opened project were displayed in the graphical preview. This has been corrected. |
|
EPLAN Platform | Labeling |
During the output of labeling data a language identifier instead of a number is output for the project property Source language (for example en-US). |
|
EPLAN Platform | Translation |
During an export of the missing-word list, no comments were exported for ambiguous texts for which there are different translations. This has been corrected. |
|
EPLAN Platform | DXF / DWG interface |
If layout display windows with an invisible frame were located in a DXF file, the contents of this display window were previously not imported. This now works. |
|
EPLAN Pro Panel | Reports |
The "Enclosure legend" report could not be updated if the view name of the underlying model view contained square brackets "[]". This now works. |
|
EPLAN Platform | Block properties |
The project property Highest revision index (ID 10098) was not offered for selection during the creation of block properties. This has been corrected. |
|
EPLAN Electric P8 | Terminals / plugs |
While inserting a device or generating terminals as a device it was possible that the number of connection points of the function was changed. This problem occurred when a symbol which had fewer connection points than the associated function definition was entered in the function templates of the part and modifications were made in the connection point logic of the symbol. The number of connection points of the function now also remains in such a case. |
|
EPLAN Pro Panel | Master data for EPLAN Pro Panel |
If you automatically generate drilling patterns from a macro project and agree to the update during the transfer into the parts management, the existing drilling patterns are no longer generated again, but only updated. |
|
EPLAN Platform | 2D panel layout |
If a rotation angle was set for the part placement in the settings for the 2D panel layout, the handle was located after the placement at a position that did not take the angle setting into consideration. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
If a complete terminal strip was placed in the layout space from the 3D mounting layout navigator, terminal parts with a number of units "0" were also considered. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
Problems occurred when an assembly for which a macro with mounting rail is stored was inserted as a device in the layout space. This has been corrected. |
|
EPLAN Preplanning | Connection planning objects |
The assignment of cable cores from the cable navigator behaved differently than the assignment of cable cores from the pre-planning navigator. This has been corrected. |
|
EPLAN Platform |
Under specific conditions texts combined into a block were not represented correctly during printing. This has been corrected. |
|
|
EPLAN Platform | Connections |
The contents of the property IDs for net-based connections (ID 20219) could not be deleted manually, and the property could also not be deleted from the property table. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
When placing a macro in the layout space by means of insertion as a macro or as a device, the property arrangement specified as default for the project was not used - even though the "Default value" was specified for the property arrangement of the associated part placement. This has been corrected. |
|
EPLAN Platform | Placeholder objects |
For properties with which the form to be used can be specified (Cable assignment diagram form, Cable-connection diagram form, etc.) it was previously not possible to select a form on the Values tab of placeholder objects. This has been corrected. If a stored form is not used in the process, it is stored in the project when the form is assigned via the value set of the function. |
|
EPLAN Pro Panel | Model views |
Under specific conditions, model views were not correctly generated in the desired page structure. This has been corrected. |
|
EPLAN Pro Panel | Model views |
When updating a model view problems occurred due to hidden items. These have been corrected. |
|
EPLAN Platform | Graphical editor |
If a QR code included texts with accent marks (such as Czech characters), these characters were not recognized correctly by mobile devices (tablet or smartphone). This has been resolved by the QR code now being saved in UTF-8 format. |
|
EPLAN Platform | Labeling |
During the output of labeling data and the "Summarized parts list" report the cable lengths were added up for several cables even though the Do not use cable when adding up cable lengths property was activated for these cables. This has been corrected. |
|
EPLAN Platform | PDF export |
Under specific conditions, pages with model views could not be output together with the associated layout space during the PDF export. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
A protective cover for busbars could not be placed in the layout space if the product subgroup "Busbar cover" was set for the part. This has been corrected. |
|
EPLAN Platform | Part selection |
In the case of repeated part selection of a part whose assigned user-defined properties have changed values, the user-defined properties were overwritten at the function without the conflict dialog being opened beforehand. This has been corrected. |
|
EPLAN API | Methods (API) |
The "GetValue" method from the "PlaceHolder" class could previously not be used if the project was write-protected. This has been corrected. |
|
EPLAN Preplanning | Creation of the detail planning |
After the placement of macros which are stored at planning objects, auxiliary functions were no longer assigned to the main function in the macro. This, for example, results in an incorrect designation for connection definition points and device connection points. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout navigator |
Module parts with describing structure identifiers were not filtered correctly in the 3D mounting layout navigator. This has been corrected. |
|
EPLAN Platform | Parts management |
When generating a new SQL database in the Generate SQL server database dialog, the entry for the database could not be inserted via copying and pasting into the Database field. This has been corrected. |
|
EPLAN Platform | 3D mounting layout |
If the size of a mounting surface on which several mounting aids were located was downsized from bottom to top or from left to right, the mounting aids were moved as well. This has been corrected. |
|
EPLAN Preplanning | Planning objects |
When placing planning objects from the pre-planning navigator the symbol stored at the function template was not considered under specific conditions. This has been corrected. |
|
EPLAN Platform | User interface |
The Layout space: Connection filter property used the wrong decimal separators. As a result the connection filter did not function. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
During the placement of a part in the layout space by means of the placement options, an entered offset value was not taken into consideration immediately after the [Enter] button was pressed. This has been corrected. |
|
EPLAN Platform | Connections |
If the Potential type property was changed at a potential definition and reset to "Undefined", the potential type entered was overwritten with the "Undefined" value at the associated connection. This has been corrected. |
|
EPLAN API | Properties (API) |
If the contents of blocks were queried by means of the "SubPlacements" property from the "Block" class, a message resulted under specific conditions. This has been corrected. |
|
EPLAN Pro Panel | Manufacturing data Rittal - Perforex / Secarex |
The manufacturing data export of a layout space for Rittal-Perforex BC was not possible because of a blank in the name of the layout space. This has been corrected. |
|
EPLAN Pro Panel | Master data for EPLAN Pro Panel |
During the import of drilling patterns from Rittal - Perforex / Secarex NC files, problems occurred with the specified point of origin. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
The updating of parts placements in the layout space via the popup menu item Update part placement is now also possible when subordinate components such as cut-outs were added to the stored macro. |
|
EPLAN Platform | Reports |
Under specific conditions the values of user-defined properties were deleted while Generating project reports. This has been corrected. |
|
EPLAN Electric P8 | PLC |
In the dialog Export PLC data the file name extension is now automatically added when the file name is entered without file name extension. If a file name extension which does not match the selected format is manually entered a prompt is shown. |
|
EPLAN Platform | Translation |
Improvements have been added for the Detect decimal numbers option in the user-specific settings for the dictionary. The characters "+" or "-" are not considered as part of a decimal number if they are listed at the end of an entry. For example, for the entry 1-pole only 1 is detected as number. Fractions must have the form "integer/integer" with optical preceding signs (e.g. 3/4, -3/4). For an entry such as, for example, 400V/230V the values 400 and 230 are detected as separate numbers. |
|
EPLAN Pro Panel | Model views |
During the output of a rotated model view with automatic dimensioning, specific items were also considered during the zero point determination for dimensioning. This resulted in an undesired offset of the dimension. This has been corrected. |
|
EPLAN Platform | DXF / DWG interface |
During the DXF export specific graphical elements for which the "Background" color was set were not output. The color assignment in the Settings: DXF / DWG export and import dialog has been extended on the Colors tab so that such elements can now be exported as well. In the corresponding color selection, selection possibilities such as "Background", "Inverse to background", etc. are also available. If a corresponding color assignment does not exist, such elements are exported to the "EPL_ADJUST" layer , and a corresponding system message is output. |
|
EPLAN Platform | Finding |
The Connection designation (ID 31011) property can now be changed again via the search results list. |
|
EPLAN Electric P8 | PLC |
Non-unique device connection points (multiple device connection points with the same DT and same connection point designation) resulted in problems during the PLC target tracking. This has been corrected. |
|
EPLAN Platform | Messages |
The check run 007016 "Device has duplicate function templates" previously did not consider the contact / coil index for coils. This resulted in an unexpected error message. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
During the simultaneous placement of several devices from the 3D mounting layout navigator a collision message was displayed for activated collision check even though the devices did not collide. This has been corrected. |
|
EPLAN Platform | Graphical editor |
If the property texts were moved for a scaled symbol on a graphical page, the property texts (for example the visible DT) could not be placed on the desired position. This has been corrected. |
|
EPLAN Platform | PDF export |
During a PDF export the line patterns of specific connections were shown differently from the display on the project page. This has been corrected. |
|
EPLAN Pro Panel | Messages |
Unplaced items are not checked anymore during check run 026011. |
|
EPLAN Platform | Reports |
Embedded enclosure legends on pages of the "Panel layout" type were deleted during the update of the enclosure legend or during Generate project reports under specific conditions. This has been corrected. |
|
EPLAN Platform | DXF / DWG interface |
On a page of the "Panel layout" type the Activate leader line display setting was activated at several part placements for the placed property Legend item. The leader lines were displayed incorrectly during a subsequent DXF / DWG export. This has been corrected. |
|
EPLAN Preplanning | Numbering |
If the option "Like designation" was set in the numbering settings of the PCT loops and PCT loop functions for the product aspect, the product aspects at the PCT loop function were not numbered. This has been corrected. |
|
EPLAN Preplanning | Creation of the pre-planning |
If the structure identifier of a planning object was changed by the numbering, this was not transferred to the placed function of the planning object via the popup menu item Update detailed planning. This has been corrected. |
|
EPLAN API | User interface |
It was previously not possible to use EPLAN API to determine the RGB values of a color which were determined at a graphical element via the color number. This has been corrected. |
|
EPLAN Platform | PDF export |
During the PDF export the ellipses located on a page were moved. This has been corrected. |
|
EPLAN Pro Panel | Manufacturing data Rittal - Perforex / Secarex |
During the NC export for Rittal Perforex BC the cut-outs of a device were not output because of missing field designations. This has been corrected. Empty field designations, for example because of part numbers which are not available, are now ignored. |
|
EPLAN Platform | Graphical editor |
After updating reports, texts in the graphical editor of an opened project were temporarily displayed in the displayed language of a second opened project. This has been corrected. |
|
EPLAN Pro Panel | Wire fabrication |
If the popup menu item Insert path variable was selected during the determination of the file name in the settings for the wire fabrication, the Project variables tab was previously not available in the subsequent dialog. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
After a part placement in the layout space was updated, an offset occurred during the part placement without the stored macro being significantly modified. This has been corrected. |
|
EPLAN Platform | Structure identifier management |
A faulty, unused structure identifier could not be deleted anymore in the structure identifier management. This has been corrected. |
|
EPLAN Electric P8 | Terminals |
If distributed terminals were placed from the terminal navigator or placed as a device, the properties Connection point description, Connection point cross-section and Connection dimension (all) were not always written at the first terminal connection point. This has been corrected. Like the connection point designations, the values of the connection point descriptions, connection point cross-sections, etc. are now correctly distributed to the individual distributed terminals and respectively written at the first terminal connection point. This correction was also made for using and assigning distributed terminals. |
|
EPLAN Electric P8 | PLC |
During the addressing of PLC connection points it could occur that a carry over for the next address part was not considered. This has been corrected. |
|
EPLAN Preplanning | Creation of the detail planning |
When Updating detailed planning with the setting Place macros again, the functions located in the macros were under specific conditions numbered, even though the option Do not modify was activated in the subsequent dialog Insertion mode. This has been corrected. |
|
EPLAN Platform | Reports |
Assemblies could not be broken up during the generation and updating of embedded enclosure legends. This has been corrected. |
|
EPLAN Electric P8 | Topology |
A topology routing path could not be connected to a topology function when this function was part of a group. This has been corrected. |
|
EPLAN Preplanning | Creation of the detail planning |
When Updating detailed planning with the setting Value sets of placeholder objects, incorrect parts were entered at specific main functions in the schematic and the function definition of terminals was changed. This has been corrected. |
|
EPLAN Platform | Page navigator |
If the displayed measuring unit for lengths was set to "Inch" and a multiple selection of pages was made in the page navigator and the grid was changed, the changed value was not applied to all pages. This has been corrected. |
|
EPLAN Platform | Graphical editor |
If the Convert component into graphic command was executed for a symbol, individual settings in the property arrangement for the Invisible display property were not applied in the converted text. This has been corrected. |
|
EPLAN Preplanning | Creation of the detail planning |
When placing macros with placeholder objects from the pre-planning navigator the images stored in the placeholder objects were only displayed after updating the value sets. This has been corrected. |
|
EPLAN API | Actions (API) |
Under specific conditions the parameters of the "ProjectAction" action were not evaluated correctly. This has been corrected. |
|
EPLAN Platform | Parts management |
The assigning of function templates via the popup menu item Assign function templates in the parts management now also functions again for stored macros that do not contain main functions but only main terminals. |
|
EPLAN Platform | 2D panel layout |
During the placement of a macro on a mounting panel with activated object snap and activated orthogonal function an unexpected error message occurred during the placement via mouse-click. This has been corrected. |
|
EPLAN Pro Panel | Model views |
An incorrectly positioned item labeling occurred in a model view when the "Hidden lines" style was used. This has been corrected. |
|
EPLAN Platform | Graphical editor |
If several structure boxes or other boxes were placed as polylines next to each other on a project page, it was possible that the DTs of the individual boxes were mixed. This has been corrected. |
|
EPLAN Platform | PDF export |
During the PDF export of a project page with a hyperlink that contained Japanese characters, an unexpected error message was shown when trying to open the hyperlink in the exported PDF document. This has been corrected. Such a hyperlink now functions. |
|
EPLAN Pro Panel | 3D mounting layout |
While Fitting rails / wire ducts for mounting rails it was possible that the position of the devices placed on it changed. This has been corrected. |
|
EPLAN Preplanning | Graphical pre-planning |
The available, describing structure identifiers were not shown any more under specific conditions after a structure segment was placed on a pre-planning page. This has been corrected. |
|
EPLAN Preplanning | Messages |
Terminals which can be assigned to a planning object are not checked anymore during check run 028009. This resulted in too many messages with the old behavior, since the corresponding device as a rule is a terminal strip and the individual terminals can be assigned to different planning objects. In addition the behavior of the check run for cables has been corrected. |
|
EPLAN Pro Panel | Model views |
Values are now output again for the Main function / Function text (of main function) property used in the property arrangements. This way the corresponding texts are displayed again in the item labeling of model views, where this property is used in a property arrangement for general devices. |
|
EPLAN Pro Panel | Model views |
In a model view it was possible that the item labeling was rotated by 90 degrees under specific conditions during the transfer of an item labeling from the layout space. This has been corrected. |
|
EPLAN Platform | Parts management |
The property Delivery length (ID 22058) is now available as a filter option in the parts management. |
|
EPLAN Pro Panel | Manufacturing data copper NC / copper DXF |
If the property Multiple cut-out possible (ID 36036) was deactivated for drill holes on copper rails, the drill holes were shortened during the subsequent moving or inserting via the clipboard. This has been corrected. |
|
EPLAN Platform | Reports |
During the generation of a summarized parts list the measuring units specified in the project-specific settings were not correctly output while the cable lengths were added up (using the placeholder text "Part reference / subset / length with unit of project"). This has been corrected. |
|
EPLAN Platform | Macros |
During the data transfer of projects from older EPLAN versions (Version 2.7 or older), the macros contained in the project receive a specific type of usage and are thus assigned to the layers "EPLAN326" and "EPLAN327". Since these layers were visible by default, the macro boxes of the macros became visible in the graphical editor. This has been corrected. The Visible setting is now deactivated by default for these two layers in the layer management. |
|
EPLAN Platform | Graphical editor |
At an auxiliary function in the schematic it is now possible again to have the technical characteristics of the main function shown again via the placed property "Main function / Technical characteristics (of main function)". |
|
EPLAN Pro Panel | Terminals |
During global editing of multi-level terminals it was possible that the connection point pattern on the part placement was changed. This has been corrected. |
|
EPLAN Pro Panel | Master data for EPLAN Pro Panel |
When system master data were synchronized, an NC outline was saved in the incorrect directory. This has been corrected. |
|
EPLAN Pro Panel | Model views |
The model views were not updated after a change of the labeling scheme. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
Problems occurred during the usage of the orthogonal function while placing devices on the busbar of a busbar system. This has been corrected. |
|
EPLAN Platform | PDF export |
In a specific case not all jump targets were correctly found after a PDF export of a project with the setting Simplified jump function. This has been corrected. |
|
EPLAN Platform | Cross-references |
At a cable with multiple auxiliary functions only the jump function for the first cross-reference worked in the graphical editor for vertically arranged cross-references for this auxiliary function. This has been corrected. |
|
EPLAN Pro Panel | PDF export |
The activated user-specific setting Update reports when printing and exporting resulted during the PDF export in all layout spaces of the project being exported irrespectively of which selection was made. This has been corrected. |
|
EPLAN Pro Panel | Master data for EPLAN Pro Panel |
During the outline check of an extrusion outline in the outline editor a missing outer outline was reported, even though it existed. This has been corrected. |
|
EPLAN Preplanning | Creation of the detail planning |
While Numbering devices in the detailed planning, values for the path function text were overwritten by empty values from the pre-planning for the function text. This has been corrected. |
|
EPLAN Platform | Parts management |
In the parts management, the property Image file (ID 22058) is now also available for the configuration of the list view. |
|
EPLAN Pro Panel | Routing connections |
While routing connections the entry into the routing path network could not be determined at an item with accessory part under certain conditions and as a result the routing connections could only be generated incompletely. This has been corrected. |
|
EPLAN Platform | Messages |
The check run message 007010 did not show the defined text at user-defined properties. This has been corrected. |
|
EPLAN Pro Panel | Routing connections |
If a routing path was inserted below an item, this could result in the (subsequently generated) routing connections not being routed according to the routing directions in the connection point pattern. This has been corrected. |
|
EPLAN API | Actions (API) |
The "restore" action could not correctly restore filed-off projects. This has been corrected. |
|
EPLAN Platform | Automated processing |
When the action "Back up data" was used during automated processing, no user-defined property could be selected here in the subsequent dialog as the path variable among the project variables. This has been corrected. |
|
EPLAN API | Properties (API) |
To specify a filter in a report block via EPLAN API it is now sufficient to enter the name of the filter scheme for the "FunctionFilterSchemaName" property from the "ReportBlock" class. The "FunctionFilterSchemaData" property is now determined automatically. |
|
EPLAN Platform | Revision control |
Filtering for automatically entered values of properties was previously not possible, - it now functions. It is now, for example, possible to filter for the value "New page created" of the property Revision description (change tracking). This value is automatically entered with enabled change tracking, when a new page is generated. |
|
EPLAN API | Properties (API) |
At dynamic symbols the coordinates of the individual connection points could not be correctly determined via the "Location" property from the "Pin" class. This has been corrected. |
|
EPLAN Platform | Pages |
An unexpected error message occurred when an object identifier was selected while copying and pasting pages in the Adapt structure dialog. This has been corrected. |
|
EPLAN Pro Panel | User-defined properties |
The values of the fields in the target project were not correctly output when copying layout spaces with user-defined properties which contained multilingual fields. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
When placing busbar adapters on a busbar, the adapters could not be placed flush despite activated object snap. This has been corrected. |
|
EPLAN Platform | Devices |
The user-specific setting Update device data after the storing of parts is now saved in the scheme of the dialog Settings: Parts (user). The setting is deactivated by default when the dialog is opened. |
|
EPLAN Pro Panel | 3D mounting layout |
Even during block-by-block placement of items per Drag & Drop in the layout space; the activated filter of the 3D mounting layout navigator is now considered again. This can, for example, mean that the placement of accessories without dimensions is prevented while placing items in a row. |
|
EPLAN Pro Panel | Model views |
Under specific conditions the property texts were positioned incorrectly when the setting From layout space was used for the output of the item labeling in the model views. This has been corrected. |
|
EPLAN Platform | Translation |
Problems could occur during the repeated entry of texts with special characters and following blanks when the Translate on input option was set in the project settings. This has been corrected. Entered texts with special characters and the following spaces now remain. |
|
EPLAN Preplanning | Creation of the pre-planning |
If new segments were created when importing pre-planning data from Excel, the structures from the segment template were not transferred. This has been corrected. |
|
EPLAN Pro Panel | Routing connections |
Under specific conditions a routing connection was not routed middle center through a defined routing path. This has been corrected. |
|
EPLAN Pro Panel | Revision control |
During the revision automatically generated model views were erroneously re-generated. In the process the existing model views were overwritten. This has been corrected. |
|
EPLAN Preplanning | Planning objects |
If the symbolic address was removed in the property dialog of planning objects in the PLC tab for a PLC input or output and this change was applied, this change was not displayed anymore in the pre-planning navigator for the PLC address. This has been corrected. |
|
EPLAN Preplanning | Creation of the detail planning |
When placing a macro with placeholder objects from the pre-planning navigator, a terminal was numbered even though the terminal designation was supposed to be entered via the set value set. This has been corrected. |
|
EPLAN Electric P8 | Terminals |
In projects which contain terminal strips with several terminals in different representation types, the updating of the navigators as well as the placement of the terminals took a long time. This now runs faster. |
|
EPLAN Platform | PDF export |
You could not jump between two structure boxes with identical DTs in an exported PDF document using the [F] key. This has been corrected. |
|
EPLAN Platform | Labeling |
If a hierarchy level with multiple, subordinate parts was marked in the tree view of the device navigator, not all parts of the device were exported during the output of labeling data for the report type "Parts list". This has been corrected. |
|
EPLAN Platform | Macros |
In macro boxes which were drawn as polygons, inner objects were not always detected correctly when they were grouped. This has been corrected. |
|
EPLAN Platform | Numbering |
The offline numbering removed displayed DTs, which were not necessary but were entered on purpose. This has been corrected. |
|
EPLAN Preplanning | Creation of the detail planning |
If a planning object with assigned part was placed from the pre-planning navigator, the part reference properties were not transferred to the function. This has been corrected. |
|
EPLAN Platform | Reports |
If no value was entered for the Thermal design: Frequency project property, this could lead to a "0" being displayed for this in the reports (e.g. title page). This has been corrected. |
|
EPLAN Pro Panel | Macros |
If the handle of a 3D macro was moved by means of the orthogonal function, the handle was moved additionally on the Z axis. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
In case of a multiple placement of female pins on terminals which are placed on a vertically arranged mounting rail in the layout space, it was possible that the female pins were placed spatially incorrectly. This has been corrected. |
|
EPLAN Platform | Placeholder objects |
In placeholder objects it is now possible to move multiple value sets simultaneously on the tab Values by using of the buttons |
|
EPLAN Electric P8 | PLC |
After re-addressing PLC connection points which occur in different representation types, it was possible in specific cases that the new addresses were not transferred to multi-line PLC connection points. This has been corrected. |
|
EPLAN Platform | Plot frame editor |
If user-defined project properties were inserted into a plot frame, the respective displayed name was not displayed anymore because of a block of other properties existing there. |
|
EPLAN Preplanning | Creation of the detail planning |
While using the Update detailed planning function, the wire data from the parts was used, even though the wire data was defined in the placeholder object. |
|
EPLAN Preplanning | Import pre-planning data |
If no properties were available for a segment during the import of pre-planning data in an Excel file, this resulted in the past in system message S181017 being output. Now, if no properties are available for a segment, this segment is ignored , and no system message is generated. If a segment has at least one property, a check is carried out as before whether an identifying name is available. The data which are missing is now specified in more detail in the system message. |
|
EPLAN Preplanning | P&I diagrams |
When placing functions from the pre-planning navigator on the P&I diagram pages it was possible that the visible DT from the pre-planning was not applied. This has been corrected. |
|
EPLAN Platform | Revision control |
In revisioned projects it was possible that report pages which contain multilingual properties were displayed as changed after updating the report and were provided with revision markers even though the project was not changed. This was due to the fact that not only project languages were considered during the update but all available languages in the parts management. Now, when updating reports, only the project languages are considered for the multilingual properties. This way, in new projects, no revision markers are generated in unchanged projects when updating reports. When updating reports in projects which were created with older EPLAN versions, revision markers can still be generated, if, for example, the parts used have more properties in the new EPLAN version. |
|
EPLAN Pro Panel | 3D mounting layout |
If devices were rotated around the Z axis in the layout space and subsequently moved, it was possible that the device was rotated into the initial position again. This has been corrected. |
|
EPLAN Pro Panel | Manufacturing data copper NC / copper DXF |
On a copper rail which was placed as a macro in the layout space, the mounting surface on the copper rail between the subsequently inserted bending positions could not be extended. This has been corrected. |
|
EPLAN View | Projects |
In EPLAN View 2022 you can now open projects from older versions (Version 2.9 to Version 2.6), without these projects having to be updated to this purpose. Starting from the current version, EPLAN retroactively supports the last five EPLAN versions. Projects from even older versions (Version 2.5 or older) must be updated before they can be opened in EPLAN View 2022. |
|
EPLAN Pro Panel | Manufacturing data copper NC / copper DXF |
If a copper rail was inserted as a device, the settings for the part placement in the dialog for the placement options could not be selected. This has been corrected. |
|
EPLAN Preplanning | Creation of the detail planning |
When Updating detailed planning with the setting Update value sets of placeholder objects the changed values from the pre-planning were not transferred to the placeholder object in the placed page macro. This has been corrected. |
|
EPLAN Electric P8 | Terminals |
Terminals can also be entered as distributed terminals by inserting devices in the project. A standard symbol is used if no symbol is specified in the corresponding function template. If a distributed terminal was inserted in this way and subsequently the symbol was changed using the [Backspace], the connection number of the first distributed terminal was set to the value "1". This has been corrected. |
|
EPLAN Pro Panel | Drilling patterns |
During the automatic generation of drilling patterns from a macro project, the page on which the drilling pattern frame was located was used instead of the selected drilling pattern frame. This has been corrected. |
|
EPLAN Platform | Parts management |
If parts from the EPLAN Data Portal were renamed or copied, this could result in problems when they were imported again. This has been corrected. |
|
EPLAN Pro Panel | Drilling patterns |
In the parts management you can determine in the drilling pattern of a part using the setting Always make that the drill holes specified in the drilling pattern are always generated on the next highest mounting surface. This means that if a part with this setting is placed on a rail or a support, drill holes are generated on the mounting panel in such a case. If parts with this setting were placed on a busbar system, this did not work correctly. This has been corrected. |
|
EPLAN Platform | Browser window |
In the browser window of EPLAN Cogineer you can now also enter line breaks by means of the shortcut keys [Ctrl] + [Enter]. |
|
EPLAN Platform | Reports |
Different values for specific placeholder texts were output and placed on top of each other during the output of a terminal diagram. This has been corrected. |
|
EPLAN Platform | Reports |
If symbols are output in a report in a terminal diagram by means of the placeholder text "Terminal / assignment: Property / value to graphic [1]", it was possible that the symbols were moved while updating the report. This has been corrected. |
|
EPLAN Platform | Subprojects |
Terminals were removed in the project when storing subprojects. This has been corrected. |
|
EPLAN API | Methods (API) |
For properties with specific filed types the "ToDouble" method from the "PropertyValue" class resulted in rounding errors. This has been corrected. |
|
EPLAN Platform | Defined working sections |
With a larger number of editors the assignment of users to workspaces did not function in the dialog Define defined working sections as administrator. This has been corrected. |
|
EPLAN Preplanning | Creation of the detail planning |
The correct variant was not considered when placing macros from the pre-planning navigator using Drag & Drop. This has been corrected. |
|
EPLAN Platform | Parts management |
If the setting Do not use anymore was activated for a user-defined property in the configuration after an import of user-defined properties into the parts management, all other imported properties were subsequently deleted. This has been corrected. |
|
EPLAN Platform | Rights management |
The menu item / command Multi-user monitor can now be hidden using the rights management. In the Rights field the associated right Call up multi-user monitor is located below the subject area System configuration. |
|
EPLAN Pro Panel | 3D mounting layout |
When changing from the normal representation to the simplified representation it was possible that terminal strips in the layout space which are placed on inclined mounting rails were not displayed correctly. This has been corrected. |
|
EPLAN Pro Panel | Routing connections |
When using a specific plug housing with insert, problems occurred with the entry point into the routing path network when routing, and the resulting connection was routed incorrectly. This has been corrected. |
|
EPLAN Pro Panel | Model views |
The edge width which was set for a model view did not function in a project. This has been corrected. |
|
EPLAN Platform | Reports |
Instead of a "0", nothing was displayed for a placeholder text with integer value when reporting a device tag list. This has been corrected. |
|
EPLAN Pro Panel | Model views |
When manually changing the dimension of multiple simultaneously selected model views the scale was only changed for one model view. This has been corrected. |
|
EPLAN Preplanning | Segment templates |
Problems could occur if the same segment template was entered as a subordinate segment template at a segment template. This has been corrected. It is now no longer possible to create nested segment templates which reference themselves. |
|
EPLAN Pro Panel | Routing connections |
In the case of a mounting rail with multi-level terminals that was mounted obliquely on a mounting panel, an incorrect course occurred during routing for the connections of the middle levels. This has been corrected. |
|
EPLAN Electric P8 | Reports |
When generating a cable overview a wrong header was output for a specific cable after switching pages. This has been corrected. |
|
EPLAN Platform | Devices |
The 007018 check run did not correctly consider parts from accessory lists if accessory lists were assigned to a part in the parts management multiple times. This has been corrected. |
|
EPLAN Platform | Labeling |
During the output of labeling data for the report type "Connection list" the specified sorting for specific properties was not taken into consideration. This has been corrected. |
|
EPLAN Pro Panel | Macros |
If the input box was activated when inserting 3D macros, the information in the displayed input box was not updated when the macro variant was switched with the [Tab] key. This has been corrected. |
|
EPLAN Electric P8 | Terminals |
When using AWG values smaller than zero (for example "3/0" or "4/0") it was possible that check run P005093 reported AWG values as faulty even though they were within the permissible range for the connection cross-section of the terminal parts. |
|
EPLAN Pro Panel | Manufacturing data NC DXF |
During the NC export of manufacturing data in DXF format the selection made was not always taken into consideration. In these cases the entire project was output. This has been corrected. |
|
EPLAN API | Parts management |
The "XPamImportCSV" converter has been removed since the different CSV formats are no longer available for exporting and importing data in the new parts management. |
|
EPLAN Pro Panel | Routing connections |
When bundling connections it was possible that not all specified sort criteria were taken into consideration. This has been corrected. |
|
EPLAN Platform | Graphical editor |
Up to 64 property arrangements can be created for a symbol variant in the symbol editor. However, previously only 32 property arrangements could be displayed in the graphical editing in the property dialog for the respective symbol variant. This has been corrected. |
|
EPLAN Platform | Parts management |
In the Function templates tab, for plug definitions and terminal strip definitions, data could erroneously be entered for some properties that relate to individual terminals or pins (such as e.g. Terminal / Pin designation). This has been corrected. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 91.1.210. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Platform | Reports |
As of Version 2.9 SP1 Update 7, the following properties are supported error-free in cable overviews: Cables: Target (ID 20377), Cables: Target (with plug designation) (ID 20385), Cables: Source (ID 20376), Cables: Source (with plug designation) (ID 20383). In the past the source and target of the cable could also be output by means of placeholder texts, alternatively to these properties. For example, the placeholder elements "Device (source) / DT (full)" and "Device (target) / DT (full)" can be used in the form to this purpose. |
|
EPLAN Preplanning | Creation of the detail planning |
When generating schematics with activated setting Place several macros on one page the placed functions under specific conditions did not apply the device tags from the pre-planning. Instead device tags with subcounters arose. This has been corrected. |
|
EPLAN Preplanning | Creation of the detail planning |
If multiple macros are placed on a page during the detailed planning, it was possible that macros which were not assigned to the respective planning object were also updated during Update detailed planning with the setting Update value sets of placeholder objects. This has been corrected. |
|
EPLAN Platform | Labeling |
During the export of manufacturing data for labeling labels, a specific format element was selected for the label while a scheme was created. After the format element had been edited, however, a totally different format element was displayed instead of the one that was originally selected. This has been corrected. |
|
EPLAN Platform | Macros |
During macro updating macros the positions of path function texts were swapped. This has been corrected. |
|
EPLAN Platform | User interface |
If several projects were opened, the popup menu item Synchronize selection for a marked function was not executed at an opened search result list. This has been corrected. |
|
EPLAN Pro Panel | Model views |
In a model view problems occurred during the display of an item labeling which can only be read from below in the layout space. These have been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
While moving a mounting point, not only the position but also the hierarchy level in the item hierarchy and thus the item allocation were changed. This has been corrected. |
|
EPLAN Pro Panel | User-defined properties |
Different problems occurred when copying layout spaces with user-defined properties. This has been corrected. |
|
EPLAN Platform | Projects |
If a project template was created from a project with macro boxes, it was possible that the created, new projects were incomplete when this project template was used. This has been corrected. |
|
EPLAN Pro Panel | Macros |
If a 3D macro was created from grouped objects in the layout space of a macro project, the grouping was not available anymore when this macro was inserted in a schematic project. This has been corrected. |
|
EPLAN Platform | Reports |
If a special project filter was used for report templates, that filtered for texts / values not be translated, then subsequently no report could be generated under certain conditions. This has been corrected. |
|
EPLAN Electric P8 | Terminals |
Problems could occur when part numbers were inserted via copying and pasting from an external list into the Edit terminal strip dialog. This has been corrected. |
|
EPLAN Platform | Reports |
During updating of a parts list, the block properties of a part definition point were no longer output. This has been corrected. |
|
EPLAN Platform | Data backup |
Projects with dots in the backup file name could not be saved under specific conditions. This has been corrected. Now a backup is only not possible when the backup file name ends with a dot and 3 digits. Such a backup file name is reserved for partial backups. |
|
EPLAN Platform | Labeling |
During the output of labeling data for the report type "Summarized parts list" a different number of plugs was exported depending on the selection. This has been corrected. |
|
EPLAN Platform | PDF export |
If external documents are displayed as QR code on report pages, these external documents were now copied again to the output directory with a PDF export with activated setting Copy externally linked documents to output directory. |
|
EPLAN Platform | Layers |
During the import of user-defined layers in the layer management it was possible that layers were imported several times or not at all. This has been corrected. |
|
EPLAN Platform | User interface |
If a group was marked in the graphical editor and subsequently the popup menu item Synchronize selection was selected, problems occurred with an opened message management. This has been corrected. |
|
EPLAN Preplanning | Creation of the detail planning |
When a macro is placed, not the entire contents of the macro were assigned to the macro. Therefore already placed consumers were not fully updated during "Update detailed planning". This has been corrected. |
|
EPLAN Platform | PDF export |
When pages with a page scale unequal 1:1 were output during the PDF export, this could mean at blocks of combined elements (for example rectangles, lines) that the graphic in the output PDF was covered by lines which were too wide. This has been corrected. |
|
EPLAN Platform | Placeholder objects |
If the value set is changed for a placeholder object of a placed macro, the changed plug designation is now transferred again to all device connection points placed next to each other. |
|
EPLAN Platform | Messages |
During the execution of the check run 007010 it was possible that different values were reported for the property Suppl. field for CLIP PROJECT data (ID 20090). This indexed property can occur in older projects and is not visible on the user interface. The property is now excluded from the check. |
|
EPLAN Platform | Reports |
When the Page sorting dialog is opened, activated settings for the check boxes Use source / target and Use placement are now displayed correctly again. |
|
EPLAN Pro Panel | 3D mounting layout |
During the placement of a busbar connection point in the layout space, not only the connection point which is entered in the connection point designation of the symbol was generated, but all connection points stored in the connection point pattern. This has been corrected. |
|
EPLAN Platform | EPLAN ePULSE |
If parts were imported from the ePULSE EPLAN Data Portal into the parts management, they could subsequently no longer be inserted from the EPLAN Data Portal into the schematic. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
When a mounting grid was generated on the busbar adapter, the grid was erroneously placed with a 90° degree rotation. This has been corrected. |
|
EPLAN Pro Panel | Manufacturing data export |
If source and target were exchanged before the export for the wire fabrication for connections, the affected connections had to be re-routed in the past so that the wire termination processing was taken into consideration correctly. This has been corrected. |
|
EPLAN Electric P8 | PLC |
The assignment of PLC connection points now also functions again for PLC connection points with a variable number of connection points. (Such PLC connection points have the function definition "PLC connection point, variable".) |
|
EPLAN Platform | Browser window |
When you clicked the search field in the browser window during the initial opening of the EPLAN Data Portal the cursor was not visible. This has been corrected. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 88.2.90. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Platform | Reports |
In the parts list the terminal / pin designations of terminals / pins that belong to an assembly are now output again. |
|
EPLAN Preplanning | Graphical editor |
In the case of autoconnecting lines in the P&I diagram for which an asymmetrical line type was set, it was possible that lines were displayed differently under certain conditions. This has been corrected. |
|
EPLAN Preplanning | Creation of the detail planning |
During "numbering devices" in the schematic, functions were also numbered which belong to a planning object without structure identifier. This has been corrected. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 88.2.90. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Preplanning | Connection planning objects |
When updating cable planning objects and when placing macros which are stored at cable planning objects, the sequence of already placed cable cores was changed. This has been corrected. |
|
EPLAN Platform | Macros |
If a macro which was generated as a protected group was copied and pasted on a schematic page, an unexpected error message occurred. This has been corrected. |
|
EPLAN Preplanning | Pipings in the pre-planning |
If the popup menu item Update detailed planning was executed for piping planning objects and the Update piping data setting was activated in the subsequent dialog, this could result in a faulty display of the flow direction. This has been corrected. |
|
EPLAN Platform | Reports |
If placeholder texts with specific formatted properties were used in the forms, no values were displayed for the placeholder texts after the reporting. This has been corrected. |
|
EPLAN API | Scripts |
If an action with an "ActionCallingContext" was inserted in a script as a parameter, this resulted in a message. This has been corrected. |
|
EPLAN Pro Panel | Views |
If a mounting rail was placed in a layout space on a user-defined rail, the drill holes of the mounting rail were not displayed in the output 2D drilling view. This has been corrected. |
|
EPLAN Pro Panel | Model views |
During the "Generate project reports", new pages of the type "Model view" were generated under certain conditions without the old pages already generated being deleted. This has been corrected. |
|
EPLAN Platform | Labeling |
During the output of labeling data for the report type "Summarized parts list" no data was output for a terminal marked on a project page. This has been corrected. |
|
EPLAN Platform | Browser window |
In the browser window of the EPLAN Data Portal, the shortcut keys for copying and inserting/pasting ([Ctrl] + [C] and [Ctrl] + [V]) only functioned unreliably. This has been corrected. |
|
EPLAN Platform | User interface |
If a multiple selection was made in the graphical editor and the popup menu item Synchronize selection was selected, problems could occur when the message management was open. This has been corrected. |
|
EPLAN Platform | Placeholder objects |
Under certain conditions no part selection could be executed in the placeholder objects for variables which are assigned to part numbers. This has been corrected. |
|
EPLAN Pro Panel | Numbering |
Items in the layout space (for example cable ducts, mounting rails, etc.) with the same DT for which no associated 2D functions exist, are now renumbered during offline numbering. |
|
EPLAN Platform | PDF export |
During a PDF export of a project page with the setting "Archiving format PDF/A" images that were located in the project directory were not included in exporting. This has been corrected. |
|
EPLAN Preplanning | Creation of the detail planning |
When project pages were generated by placing page macros from the pre-planning navigator, conductors were subsequently no longer assigned to the cable in the macro. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
If the mounting point was selected while placing a cut-out on a mounting point in the subsequent selection list, an unexpected error message occurred. This has been corrected. |
|
EPLAN Pro Panel | Master data for EPLAN Pro Panel |
By default subdirectories are not considered anymore when searching for outlines during the master data synchronization. As a result the performance while synchronizing master data has improved. |
|
EPLAN Pro Panel | 3D mounting layout |
When placing terminals with accessories on a terminal strip in the layout space, the sequence of the accessories is now considered correctly again. |
|
EPLAN Pro Panel | Routing connections |
The routing of connections now also functions again when only the busbar connection points (adapter) are marked in the layout space from the items "Terminals" and "Busbar connection points" which are connected to each other in the multi-line schematic. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 86.0.241. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Pro Panel | Reports |
A manually placed mounting list was no longer correct after the update. This has been corrected. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 86.0.241. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Pro Panel | 3D mounting layout |
Selection of mounting points and mounting lines When inserting mounting points and mounting lines, it is now again possible to assign a name that is already assigned to mounting points and mounting lines (menu path: Edit > Device logic > Mounting point and Edit > Device logic > Mounting line). The [...] button next to the Name field in the property dialog of these mounting aids is available to this purpose. The selection is carried out in the subsequent dialog in which all names already assigned are listed. |
|
EPLAN Platform |
New setting for black and white printing The new setting Invert white graphical elements is now available in the dialog Settings: Print when black and white printing is activated. If this check box is selected, graphical elements which have been assigned the EPLAN color numbers 8, 255, 263, 264 and 266 are output in black. A corresponding setting is also available in the dialogs for the PDF and image file export. |
|
|
EPLAN Platform | User interface |
Under certain conditions it was not possible to open a popup menu in a navigator. This has been corrected. |
|
EPLAN Platform | Multi-user operation |
If the project properties are being edited by a user and another user opens the same project, the dialog Multi-user conflict is now displayed instead of a message. |
|
EPLAN Platform | EPLAN ePULSE |
When an Internet connection was not available, an error message was displayed that the ePULSE service could not be reached, even when the EPLAN ePULSE window was closed. This has been corrected. |
|
EPLAN Platform | Parts management |
The importing of edz files with user-defined properties could take very long. To speed this up a change was carried out in the creation of the export file. |
|
EPLAN Platform | Properties |
The field type was changed at many properties for Version 2.9 SP1. During the entry of values (for example for the Technical characteristic field) this could result in the entered decimal separators ("," or ".") being changed to the separator which is set in the operating system. This has been corrected. |
|
EPLAN Platform | Connections |
The values defined in a connection filter are now applied again to all highlighted routing paths in the layout space or in the topology. |
|
EPLAN Platform | EPLAN ePULSE |
Certain links did not work when called up via the EPLAN Tutorials window or from the EPLAN ePULSE window. This has been corrected. |
|
EPLAN Platform | Plot frame editor |
In Version 2.8 the numbering of the column designations was repeated and not continued under specific conditions at alphanumeric column numbering formats. This has been corrected. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 84.4.10. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Platform | Graphical editor |
Multi-line plugs from the "SPECIAL" symbol library were not displayed anymore on the page in the graphical editor after the symbol selection. This has been corrected. |
|
EPLAN API | Actions (API) |
The "ExportProductionWiring" action can be used to export manufacturing data into different formats for the wire fabrication. Despite the specified parameter "/MACHINETYPE:9" being used, the export to the "Rittal - Wire Terminal WT" format did not function. This has been corrected. |
|
EPLAN Electric P8 | PLC |
During importing in the AutomationML format, parts are also assigned for which the PLC type designations only differ by a different number of blanks - if there is no part with exactly matching PLC type designation. |
|
EPLAN Platform | EPLAN ePULSE |
The contents of an input field in the EPLAN ePULSE window could not be deleted by means of the [Del] key. This has been corrected. |
|
EPLAN Platform | EPLAN ePULSE |
When an ePULSE account was linked with a Microsoft account within the EPLAN ePULSE window, problems occurred under specific conditions. This has been corrected. |
|
EPLAN Platform | Cross-references |
After a correction, the setting Display full structure identifier in cross-reference for interruption points in Version 2.9 had an effect on the cross-reference abbreviation rules for functions. This has been corrected. The cross-reference abbreviation rules for functions which refer to the full DT now function again. |
|
EPLAN Platform | EPLAN ePULSE |
EPLAN now remembers the EPLAN ePULSE login information for the restart. This means that users do not have to enter login information for every start of the EPLAN platform when they open the ePULSE window. |
|
EPLAN Platform | Parts management |
During synchronization of parts of stored project parts with monolingual user-defined properties into another parts database, existing values were not applied. This has been corrected. |
|
EPLAN Pro Panel | Master data for EPLAN Pro Panel |
After a modification at an outline (extrusion) problems occurred during the subsequent placement as a user-defined rail. This has been corrected. |
|
EPLAN Pro Panel | Routing connections |
When routing connections in a wiring system, incorrect results occurred in some cases during the calculation of the routing direction. This has been corrected. |
|
EPLAN Preplanning | Segment definitions |
Problems occurred while using user-defined icons and / or image files for segment definitions. This has been corrected. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 84.4.10. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Platform | User interface |
When using user-defined toolbars in connection with the rights management it was possible that icons and the associated commands could not be assigned correctly to each other. This has been corrected. |
|
EPLAN Platform | Part selection |
After the part selection of updated parts, data was changed at the functions in the schematic, even though the "Retain" option was selected in the conflict dialog opened in the meantime. In addition an unexpected system error message occurred. This has been corrected. |
|
EPLAN Pro Panel | Routing connections |
During routing, a routing direction could not be determined for all routing connections. This has been corrected. |
|
EPLAN Platform | Labeling |
During the output of labeling data, breaks were output although the Apply line breaks setting was deactivated. This has been corrected. |
|
EPLAN Pro Panel | Master data for EPLAN Pro Panel |
The master data synchronization now also takes into consideration such outlines (NC and Extrusion) that are located in subdirectories of the macro directory. |
|
EPLAN Platform | Graphical editor |
While inserting dynamic symbols with polylines problems occurred when the object snap was activated. These have been corrected. |
|
EPLAN Pro Panel | Routing connections |
The determination of the routing direction has been optimized for the routing of connections in a wiring system. |
|
EPLAN Pro Panel | 3D mounting layout |
During the multiple placement of auxiliary switches on the left-hand side of an associated power circuit breaker it was possible that the auxiliary switches were placed into each other. This has been corrected. |
|
EPLAN Platform | User interface |
While registering add-ons, master data was not copied under specific conditions. This has been corrected. |
|
EPLAN Pro Panel | Master data for EPLAN Pro Panel |
If guide rails were inserted as logic elements in the outline editor for extrusions, the counter for the guide rails did not start with "1", as with the other logic elements, but depending on the number of other logic elements (for example mounting surfaces) already inserted. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
During the placement of a terminal strip with labels on a mounting rail, the terminals were not placed correctly at the first terminal. This has been corrected. |
|
EPLAN Platform | Revision control |
The Highest revision index (change tracking) property is only determined when the project contains revisions. As a result the performance while closing projects has improved. |
|
EPLAN Pro Panel | Master data for EPLAN Pro Panel |
If user-defined NC outlines were edited subsequently, these could not be updated in the projects in which the NC outlines were placed as cut-outs of the type "From drilling pattern". This has been corrected. The NC outlines are now updated after a master data synchronization. |
|
EPLAN Electric P8 | PLC |
During the import of PLC configuration data in the AutomationML format the identifier is now automatically added if it is not available in the import file. The identifier is determined from the format for the PLC addresses which is stored in the scheme used for the PLC-specific settings. |
|
EPLAN API | Classes (API) |
If the "IncludedElements" property was erroneously set for the "ViewPlacement" class, the model view (2D drilling view) of a drilling pattern could not be updated. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
If devices were placed on mounting rails from extrusion outlines, differences could occur for the placed devices, depending on whether the outlines for the mounting rails were stored in the Mounting data tab or in the Technical data tab in the parts management. This has been corrected. |
|
EPLAN Platform | Reports |
In a report of the type "Parts list" (cutting list) decimal places were displayed for a length, even though no decimal places were set in the associated placeholder text in the formatting properties. This has been corrected. |
|
EPLAN Electric P8 | Terminals / plugs |
If terminals or pins were sorted via drag & drop in the dialog Edit terminal strip or in the dialog Edit plug, problems occurred under certain conditions. This has been corrected. |
|
EPLAN Pro Panel | Manufacturing data NC DXF / Copper DXF |
During the export of manufacturing data NC DXF and copper DXF for machining, old AutoCAD versions are now supported again. In the settings on the DXF general tab versions such as AutoCAD 2.5, AutoCAD 10, AutoCAD 12, etc. are now available again in the AutoCAD version field. |
|
EPLAN Platform | Reports |
When placeholders with formatted properties were used in forms, problems occurred with the display of decimal separators after the generation of reports on the report pages. This has been corrected. |
|
EPLAN API | Methods (API) |
During the export of parts data from the class "PartsService" by means of the "ExportPartsListFromSystem" method no user-defined properties were exported. This has been corrected. |
|
EPLAN Platform | EPLAN ePULSE |
If scripts were loaded in the EPLAN Platform, this could result in it not being possible to download parts from the new EPLAN Data Portal. This has been corrected. |
|
EPLAN Platform | Graphical editor |
The values for the property Connection: Cross-section / diameter of cables are now also correctly displayed in the graphical editor if no unit is entered. |
|
EPLAN Platform | Labeling |
During the output of labeling data for the report type "Device tag list", a line break was always output, even if the Apply line breaks setting was deactivated in the associated labeling scheme. This has been corrected. |
|
EPLAN Platform | Devices |
New setting for updating device data If the parts in the project are older than in the parts database, the newer data is stored in the project during a parts database synchronization. The new user-specific setting Update device data after the storing of parts can be used to determine whether the device data in the project should be updated as well or not. (Menu path: Options > Settings > User > Management > Parts). |
|
EPLAN Platform |
New behavior for black and white printing Individual graphical elements were not included in the output for black and white printing. These are graphical elements that are, for example, displayed in white or black when the color scheme setting "Black" is set in the graphical editor. So that these elements also appear in the output, graphical elements with the EPLAN color numbers 8, 255, 263, 264 and 266 are now output in black when the "Print in black and white" setting is activated during printing and during the PDF and image file export. |
|
|
EPLAN Platform | User interface |
Menu items created by script are now listed again in the dialog for specification of the shortcut keys under "Select command". |
|
EPLAN Platform | Data backup |
The performance during the restoring of projects has been improved. |
|
EPLAN Platform | Reports |
If the table of contents needs to be updated after a change of the date format, the date is now shown again in the set date format. |
|
EPLAN Pro Panel | Model views |
The restrictions with regard to the inclination of texts have been deactivated for the display of the item labelings in the model views. This way the item labelings that were only readable from the top in the layout space are displayed again. |
|
EPLAN Pro Panel | 3D mounting layout |
The marking of an object selected in the layout space now remains even after an action abort. |
|
EPLAN Pro Panel | 3D mounting layout |
If the 3D macro of a placed item is removed and then reselected, the subsequent update of the part placement now does not result in a position change for the item anymore. |
|
EPLAN Pro Panel | 3D mounting layout |
During the multiple placement of items the assignment of legend positions has been accelerated. This way the placement takes part faster. |
|
EPLAN Platform | PDF export |
Pages of the type "External document" were under certain conditions not output anymore during the PDF export. This has been corrected. |
|
EPLAN Platform | Edit in table |
While opening the Edit in table dialog the selected functions are now displayed faster again - even for comprehensive projects. |
|
EPLAN Platform | Browser window |
Double entries arose in EPLAN Cogineer during the pasting of copied texts from the Clipboard. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
When devices are inserted into the layout space, structure identifiers from the stored 3D macro are no longer applied for the part placements located below an enclosure and the Displayed DT field remains empty. |
|
EPLAN Platform | Graphical editor |
During the display of a contact image (for example for coils) the display properties for the first and second part were displayed swapped. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
The placement area in the stored macro is considered again while inserting a module as a device into a layout space. |
|
EPLAN Platform | Graphical editor |
When the object snap is activated, only the circle center is found as the snap point again at the handle of a macro box. |
|
EPLAN Platform | Parts management |
While working in the parts management with an SQL parts database, an unexpected error message occurred while importing translated parts texts. This has been corrected. |
|
EPLAN Pro Panel | Routing connections |
For the function of routing connections across routing ranges it was previously not planned that the routing range could be located on mounting surfaces that slope. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
During the placement of items in the layout space not all available mounting surfaces were automatically activated when the cursor was moved over the surfaces or items under certain conditions. This has been corrected. |
|
EPLAN Electric P8 | PLC |
Since Version 2.9 multi-line bus ports are also taken into consideration during check runs of the class "PLC / bus". These check runs (for example 004039, "Connection between different bus systems") therefore took a long time in projects that contain many multi-line bus ports. This has been improved. |
|
EPLAN API | Methods (API) |
Menu items that were added to the user interface via the "AddMenuItem" method could not be displayed in some cases. This has been corrected. |
|
EPLAN Pro Panel | 3D mounting layout |
During the placement of a part the data from the stored macro are now taken into consideration again for the protective cover of a busbar support. |
|
EPLAN API | Actions (API) |
Objects that are to be exported for the output of manufacturing data / labeling data by means of the "label" action, are now detected correctly again. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 83.4.20. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Platform | Part master data navigator |
Problems occurred in the part master data navigator while working with the full-text filter. These have been corrected. |
|
EPLAN Platform | Browser window |
Optimizations for the new Data Portal Under certain conditions, the download of parts data was restricted. This now works. |
|
EPLAN Platform | Rights management |
When the rights management was used with imported Active Directory groups, problems occurred if the users belonged to other domains. These have been corrected. |
|
EPLAN API | Methods (API) |
If the "OnSelect" method was used at a "SelectionInteraction" created per EPLAN API, an exception of the "Eplan.EplApi.DataModel.InvalidHandleException" type occurred under specific conditions. This has been corrected. |
|
EPLAN Platform | Browser window |
The Chromium component "CefSharp" has been updated to the current version 81.3.100. This component is used for the display of contents in the browser windows of the EPLAN platform (for example EPLAN Data Portal, EPLAN Cogineer, etc.). |
|
EPLAN Platform | Connections |
Extended settings for the reset area of the connection numbering In the Designation tab of the Settings: Connection numbering dialog you specify the format for the connection designations. A menu path to these settings is: Options > Settings > Projects > "Project name" > Connections > Connection numbering. When the format for the counter is specified you now additionally have the possibility to have the counter reset when the schematic path changes. The new Schematic path check box is available in the Settings: Counter reset range dialog to this purpose. |
|
EPLAN Platform | Properties |
Changeover of properties to the field type "Value with unit" For many properties (for parts, functions, connections, etc.) the field type was changed from "Monolingual text" to "Value with unit". Therefore the representation of the decimal separators now complies with the settings of the operating system. This means that not the entered decimal separators ("," or ".") but those set in the operating system are displayed. |
|
EPLAN Platform | EPLAN ePULSE |
Connection of the new EPLAN Data Portal The new EPLAN Data Portal is now available as a Cloud application under EPLAN ePULSE in the EPLAN Platform. After signing in you also have access to the parts data of more than 300 leading manufacturers in the new EPLAN Data Portal. The user interface of the new EPLAN Data Portal has been revised and completely redesigned. Search results are now shown more quickly through an improved search function. Easily accessible selectors and configurators of leading component manufacturers have also been integrated. With the introduction of the new EPLAN Data Standard standardized parts data are available and can be detected easily. |
|
EPLAN Platform | Parts management |
Updating the Parts Database The parts database of the parts management has been updated for Version 2.9 SP1. If you now open an "older" parts database in the EPLAN platform (Version 2.9 or older), you have to update the parts database before you can edit it. Updated old and new (from 2.9 SP1) parts databases can be opened (for example, for parts or device selection) in older EPLAN versions (Version 2.9 or older) but not edited. |
|
EPLAN Platform | Parts management |
Support of the eCl@ss Version 9.1 During the import of parts data into the parts management the eCl@ss Version 9.1 is now supported in addition to the eCl@ss Versions 9.0 and 10.0.1. |
|
EPLAN Electric P8 | PLC |
PLC schematic generation available during importing of PLC data in the AutomationML format During the import of PLC data in the AutomationML format the option Start "Generate PLC schematic" was not available in the Import PLC data dialog in the past. This functionality is now also available for the import of PLC configuration files in the AutomationML format. |
|
EPLAN Electric P8 | PLC |
Information during the import of files with a higher AutomationML version An import file in AutomationML format is always imported irrespective of the AutomationML version with which the file was created. This means that all the data known for the respective EPLAN version is imported. As of EPLAN Version 2.9 SP1 an information is now displayed when an import file with a higher AutomationML version is created than that supported by the used EPLAN version. In this case it is possible that not all the data contents are imported. |
|
EPLAN Electric P8 | PLC |
New "MELSECNET/H" bus system The new bus system "MELSECNET/H" is available in the Bus data tab at bus ports. |
|
EPLAN Pro Panel | Model views |
View dialogs extended with Apply button The [Apply] button is now also available in the Model view, Unfold and Drilling view dialogs. This way you can check a modified item labeling or other modifications of the view faster without having to constantly close or open the respective dialog. |
|
EPLAN Preplanning | Segment templates |
Subordinate segment templates It is now possible in the segment template navigator to create nested segment templates - this means segment templates with subordinate segment templates. To this purpose the Segment templates tab has been extended with the table Subordinate segment templates. By means of the subordinate segment templates, you quickly create nested structures with subordinate structure segments, planning objects and / or PCT loops and adjust them quickly during modifications. |
|
EPLAN Platform | Master data |
Master data: New isolating terminal symbol The standard symbol libraries for the IEC, GOST, GB and NFPA standards have been extended with a new symbol for an isolating terminal: " |
|
EPLAN Platform | Master data |
Master data: New symbols for fluid power The "PNE1ESS" symbol library for fluid power has been extended with a symbol for a valve actuation and two symbols for valve outlines: " |